Requests That NRC Staff Make Correction in Westinghouse NSD-JLH-6384 & NSD-JLH-6385 Ltrs Re Qualification Testing of Lower Joint for Elevated Sleeve
ML20134K658
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 11/14/1996
From: Dennis Morey
SOUTHERN NUCLEAR OPERATING CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9611190263
Download: ML20134K658 (2)


Text

{{#Wiki_filter:-.... - ~ ~ Southern Nucim Optr: ting Company -

  • ~~' Post Offica Box 1295 Birmingham. Alabama 35201 Tsliphona (205) 868-5131 o.s.uor.y Southern Nudear Operating Company Vice President 1

- Farley Project the southem electnc system November 14,1996 i i Docket No.: 50-364 10 CFR 50.90 i U. S. Nuclear Regulatory Commission . ATTN: Document Control Desk Washington, DC 20555 Joseph M. Farley Nuclear Plant - Unit 2 Elevated Tube Sheet I neer Welded Sleeve Technical Snecification Amendment Ladies and Gentlemen: As a result of an NRC Staff request, Southern Nuclear forwarded by letter dated November 11, 1996, Westinghouse letter NSD-JLH-6384 dated November 8,1996 concerning the qualification testing of the lowerjoint for the elevated sleeve. A non-proprietary version of that letter, NSD- - JLH-6385, was included with the Southern Nuclear letter. An error has been identified in the Westinghouse letter. In the last paragraph on page 3 of the ] letter, the first sentence should conclude, "..., will be lower than in a rolled tube." instead of "..., will be higher than in a rolled tube." Consequently, the entire paragraph should read: 1 Everything else being equal, it is expected that the integrity of thejoint installed in a WEXTEX tube, the subject of this task, will be lower than in a rolled tube. Therefore, the performance of the joint made in the WEXTEX tube is expected to bound the performance of the samejoint made in a rolled tube and the roll last, undegraded, factory rolled tube configuration was not scheduled for testing. (The "same" joint is defined as the joint made using the same roll expander, torque, roller rpm, roll pass sequence, effective length. es well as tube, tubesheet and sleeve material and strength parameters.) It is requested that the NRC Staff make this correction in both the Westinghouse NSD-JLH-6334 and NSD-JLH-6385 letters. 9611190263 961114 PDR ADOCK 05000364 P PDR

1 r- ~ U. S. Nuclear Regulatory Commission Page 2 ' If you have any questions, please advise. Respectfully submitted, SOUTHERN NUCLEAR OPERATING COMPANY N ??l44' Dave Morey 4 Sworn to andsubscribedbefore me this$ day of bc0 1996 hgs.cLekoJ

== ~ Notary Public My Commission Expires: O> '=bJL9 Aooo u REM / :ETSSUPP2. DOC cc: .Mr. S. D. Ebneter, Region II Administrator Mr. J.1. Zimmerman, NRR Project Manager Mr. T. M. Ross, Plant Sr. Resident Inspector Mr. T. A. Reed, NRR - Materials and Chemical Engineering Branch Dr. D. E. Williamson, State Department of Public Health-I [ f. =}}