January 29, 1997 MEMORANDUM T0:
David B. Matthews, Chief Generic Issues and Environmental Projects Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation FROM:
Egan Y. Wang, Reactor System Engineer original signed by:
Generic Issues and Environmental Projects Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation 1
SUBJECT:
MEETING
SUMMARY
OF JANUARY 9, 1997, REGARDING ANFB CORRELATION AND BWR REFLOOD CRITERIA i
On January 9, 1997, representatives of Siemens Power Corporation (SPC) met with representatives of the Nuclear Regulatory Commission (NRC).
Participants of this meeting also include representatives from Commonwealth Edison Company and Pennsylvania Power & Light Company. The purpose of this meeting was to provide an opportunity for SPC representatives to review and discuss ANFB correlation for Atriun-10 application and BWR reflood criteria issues.
SPC representatives provided an introduction and a brief description on current activities with regard to the issues.
Most of the meeting involved presentation of proprietary information. provides a list of meeting attendees. Attachment 2 is the non-proprietary version of the presentation material. Attachment 3 is the material presented by TU representative.
Attachments: As stated cc w/att:
See next page DISTRIBUTION:
See attached page 1
Document name: 970109MT. SUM
[
f 0FC PGEB C, 1 SC:PGEB / h C:PhBh (
NAME EWang:sE FAkstbl/dbz DMathws g
_DATE 01P[/97 01h9 /9/
@/k/97 0FFICIAL RECORD COPY 97-J1fr NRC ERE CENTER COPY hrd EX kCfm-U N b *(
9702120387 970129 PDR TOPRP EMVEXXN PDR
kn ug j
p 4
UNITED STATES i
j j
NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20086 4 001.
January' 29, 1997 MEMORANDUM TO:
David B. Matthews, Chief Generic Issues and Environmental Projects Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation FROM:
Egan Y. Wang, Reactor System Engineer Generic Issues and Environmental N
v Projects Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation
SUBJECT:
MEETING SUMARY OF JANUARY 9,1997, REGARDING ANFB CORRELATION AND BWR REFLOOD CRITERIA On January 9,'1997, representatives of Siemens Power Corporation (SPC) met with representatives of the Nuclear Regulatory Commission (NRC).
Participants of this meeting also include representatives from Commonwealth Edison Company and Pennsylvania Power & Light Company. The purpose of this meeting was to provide an opportunity for SPC representatives to review and discuss ANFB correlation for Atrium-10 application and BWR reflood criteria issues.
SPC representatives provided an introduction and a brief description on current activities with regard to the issues.
Most of the meeting involved presentation of proprietary.information.
Attachment I provides a list of meeting attendees. Attachment 2 is the non-proprietary version of the presentation material.
Attachments: As stated cc w/att:
see next page e
i 1
1 l
l cc:
l' Mr. H. D. Curet, Manager Product Licensing Siemens Power Corporation 2101 Horn Rapids Road P. O. Box 130 Richland, WA 99352-0130
..=.__.
-. -.. =.
4-3 DISTRIBUTION: Mtg. Summary of January 9, Meeting with Siemens Power Corporation Dated January 29. 1997 HARD COPY central File 4
Public PGEB r/f R. Cooper, RI E. Nerschoff, RI!
W. Alexion, RIII l
J. Dyer, RIV L. Phillips E. Wang OGC ACRS E-MAIL i
F. Miraglia l
A. Thadani R. Zimmerman T. Martin E. Jordan D. Matthews F. Akstulewicz i
4 t
1 1
j k
i 97-SV
^
MC Hlf CEME8 COPY 120059
j i
1 NRC/SIEMENS POWER CORPORATION MEETING l
DN CONTROL ROD INSERTION ISSUES LIST OF ATTENDEES January 9, 1997 liatiE ORGANIZATION Copeland, R. A.
Siemens Ingham, Jerry Siemens i
Curet, Don Siemens 4
Keheley, Tom Siemens Garrett, Michael Siemens Lehmann, Chet PP&L Spadaro, John PP&L Kulick, John PP&L Maron, Drew PP&L Sgarro, R. R.
PP&L Benes, Gary Com Ed Freeman, John Com Ed Wu, Shih-Liang NRC/NRR/DSSA/SRXB Phillips, Larry NRC/NRR/DSSA/SRXB Pulsifer, Bob NRC/NRR/DRPW l
Skay, Donna NRC/NRR/DRPW Ulses, Anthony NRC/NRR/DSSA/SRXB Matthews, Steven NRC/NRR/ DISP /PSIB Kendrick, Edward NRC/NRR/DSSA/SRXB Huang, Tai NRC/NRR/DSSA/SRXB i
Wang, Egan NRC/NRR/DRPM/PGEB t
4 ATTACHMENT 1
SIEMENS NRC/SPC Meeting on BWR Methodology January 9,1997 P
t Siemens Power Corporation Proprietary
= -
m
I SIEMENS l
Purpose of Meeting Review the application of ANFB correlation for the ATRIUM-10 design to show the application to be consistent with the NRC approval
. Describe the reflood criteria application in BWR LOCA analyses
"{'
a Siemens Power Corporation Preprietary
SIEMENS Agenda
. Introduction--HD Curet
. ANFB Application for ATRIUM-10--TH Keheley Safety Limit Analysis--JG Ingham
. BWR Reflood Criteria Application--ME Garrett
~
Summary / Conclusions--HD Curet I
n Siemens Power Corporation Proprietary 5
SIEMENS ANFB for the ATRIUM-10 design
. SPC did not change or alter the ANFB methodology for
}
r the ATRIUM-10 fuel
. SPC established the additive constants on the most restrictive data
. The predicted margins to limits are more conservative l
than would be predicted with a modified ANFB i
correlation supported by all CHF test data l
l l
Siemens Power Corporation Proprietary j";'
1 e
---e.
~
-v.-
SIEMENS SPC is using a supplementary reflood criterion SPC was concerned about the relative reflood criterion in FLEX and applied a supplementary, conservative quantitative criterion
. Based on entrainment tests, SPC proposes the use of a less conservative supplementary criterion Annual notification procedures are anticipated to be appropriate for reporting the reflood criteria change
'W 5
Siemens Power Corporation Proprietary
SIEMENS l
l i
ANFB Performance with ATRIUM
-1 l
i Thomas H. Keheley Staff Engineer, Safety Analysis Methods i
t i
i f
l
- iam, i
i
SIEMENS ANFB Performance with ATRIUM
-10
. The ANFB data base contains [
] data points with a mean ECPR of [
] and standard deviation of [
].
The data base contains tests on [
] rod arrays.
. The axial profiles in the data base are [
]
and uniform.
h i
mm, g
l i
SIEMENS ANFB Performance with ATRIUM
-10
. The ANFB correlation has the form of:
l 1
4 1$$EOS
j t
SIEMENS ANFB Performance with ATRIUM
-10 The [
] in the [ ] term is used to account for the physical differences in test bundles, such as array type, rod pitch, or spacer type.
j
. When a new bundle is tested, the [
] is determined from the test data to give the best fit of predicted to i
measured data.
The [
] is then used to calculate an additive constant that is applied to the fuel assembly.
l
,me, i
i
SIEMENS i
ANFB Performance with ATRIUM
-1 0
. In September of 1992, Siemens performed dry out tests on the ATRIUM
-10 assembly (test series STS-l 17D. The ATRIUM
-10 assembly has 8 part length l
rods.
l 1
The dry out tests were performed on a bundle with a
)
. A total of [
] data points were tested.
The overall ECPR for the STS-17 series of tests was
[
] with a standard deviation of [
].
l I
I 5
mm
SIEMENS i
ANFB Performance with ATRIUM
-10
. In the Spring of 1994, GE presented a paper i
suggesting that GEXL did not predict up skew ~axials when part length fuel rods were present.
. By the Spring of 1995, Siemens had allocated R&D funds to confirm ANFB performance with up skew and down skew axial power profiles with part length rod t
assemblies.
. Testing commenced during the Summer of 1996.
Data for the up skew tests were received during the first week of November,1996.
. Analysis of the test data indicated that ANFB is about
] conservative for down skew axial power profiles and on average about [
] non-conservative for up skew axial power profiles when part length rods are oresent.
j i
m_
SIEMENS ANFB Performance with ATRIUM 10 t
t 112219 1 I
SIEMENS ANFB Performance with ATPIUM
-10
SIEMENS ANFB Performance with ATRIUM
-10
. The up skew test performed was a repeat of [
test STS-17.4.
This test was chosen because the trends and statistics of the test indicated that it should be the [
]
l performer.
. Because there are [
] tests and [
] test, the [
] tests were examined closely for trends that would predict the [
] of the up skew test.
I t
i l
l i
o s
l i
'Q= @@@@@@@@@
l s
89@@@@@@G@
l 2
l E
l 4
Q@@@'
@@@,j l
5 GkOQ@c
>@@@ ~i*
l B
i 8
E
@@@@@@@@S@
~
l E
00@@@@@@@@;
h e
i O.-
~$
U j
w u_
l 3
2 a
l
SIEMENS ANFB Performance with ATRIUM-10
. Four tests from the [
] axial power tests showed a trend of [
] the critical power performance at the lowest test flow rate.
STS-17.4 STS-17.9 STS-17.10 STS-17.11
. The FEFF's for these tests were adjusted such that ANFB predicted the [
] performance.
. The additive constants for the rods affected and their symmetric rods were adjusted to conform with the new FEFF's.
All rods then had an additional [
] applied to the additive constants.
n
SIEMENS ANFB Performance with ATRIUM-10 I
h I
l e
i i
1122/97 gg l
r
SIEMENS ANFB Performance with ATRIUM-10 Test O ld E C P R New ECPR S T S -17.4
[
]
[
]
l S T S -17.9
[
]
[
]
S T S -17.10
[
]
[
]
S T S -17.1 1
[
]
[
]
1 t
b
![kI I
$3
SIEMENS ANFB Performance with ATRIUM-10
SIEMENS ANFB Performance with ATRIUM 10 f t22/97 l
l 15
. _ __ _ _ _ _ __. _ _ _ _._._- _..... _._..-.-.._. _ _ _._... ~.
SIEMENS t
ANFB Performance with ATRIUM
-10 l
1
. When ANFB is used to predict up [
] power profiles for part length rods, it is [
].
. The cosine data was examined to find the same type of l
[
]; the FEFF for those tests were evaluated to j
get an [
].
j All additive constants were [
] for added conservatism; the result is that the STS-17 series has an
].
The evaluation of the up skew test then resulted in an
[
].
There are no changes in methodology for data reduction or in the correlation to account for [
]; the down skew conservatism remains.
mm, i
i
SIEMENS Core Reflood Time With the EXEM BWR LOCA Evaluation Model i
Presented by:
\\\\
Michael E. Garrett, Manager
\\
D t
I l
BWR Safety Analysis i
Nuclear Engineering l
January 9,1997 I
l
-,C 1
sisusus Purpose I
l Describe how SPC determines the time of core reflood in applications using the NRC-approved EXEM BWR LOCA methodology Describe an SPC internal requirement that is used to supplement the core reflood criterion described to the NRC i
MEG S
=
e SIEMENS i
===.
Background===
. The FLEX computer code is used to determine the reactor core and system response during the refill and reflood phases of a LOCA l
t
. ;2 LEX calculates the time when two-phase flow reaches the hot
(
node in the core. This is referred to as the " time of hot node l
reflood" or more simply as the time of core reflood j
. The time of core reflood is an input to the fuel assembly heatup r
analysis performed using the HUXY computer code
. At core reflood, the heat transfer coefficients (HTCs) used in the j
heatup analysis increase by about an order of magnitude from the l
Appendix K spray HTC to the Appendix K reflood HTC l
. The higher reflood HTC is sufficient to remove decay heat from the fuel rods and results in the termination of the fuel rod temperature excursion d,":
~
SIEMENS Core Reflood Criterion i
1
. FLEX calculates the level of the two-phase mixture entering the core, the entrainment of liquid from the mixture, and the movement of the entrained liquid flow through the core
. Because it is the entrained liquid and not the mixture level itself that initially results in increased heat transfer effectiveness, FLEX uses the time that two-phase entrained liquid reaches the plane of interest as the definition of the time of hot node (core) reflood j
Approach is consistent with the Appendix K definition for using the reflood heat transfer coefficient "after the two-phase reflooding fluid reaches the level under consideration" Approach for determining the time of core reflood is discussed in the EXEM BWR LOCA methodology topical reports XN-NF 19(P)(A) and ANF-91-048(P)(A) 182119 7 4
MEG.97.003 l
I SIEMENS Core Reflood Criterion (continued) l l
l
. The parameter used in the FLEX calculation to determine the time l
of core reflood is the relative entrainment (RELENT) at the plane of l
interest
. RELENT is the The parameter is a l
measure of the i
.A value of RELENT indicates that j
and that liquid is available to cool the fuel rods and terminate the cladding heatup
(
. A sustained value of RELENT is the criterion used to determine the time of core reflood for LOCA analyses using the
~
1982 EXEM BWR LOCA methodology 1121'87 6
MEG.97 003 I
I SIEMENS Core Reflood Criterion (continuedD The benchmarking of FLEX to test data indicates that the relative entrainment criterion is sufficient to predict when adequate cooling is available at the hot node l
t l
l l
l l
m.m MEG.9 7.OO3
SIEMENS Supplementary Requirement for Core Reflood i
. During the development of the revised EXEM BWR LOCA methodology (approved in 1993), SPC had a concern about the j
need for an absolute entrainment criteria i
i l
. Although experimental data indicates that the initiation of liquid entrainment leads to a significant increase in heat transfer, a supplementary reflood requirement was introduced to address this concern
. With the supplementary requirement, the time of core reflood is determined based on the relative entrainment criterion described in i
the topical report combined with a requirement related to the l
absolute entrained liquid flow rete l
t I
i ussier i
[
wo orm
~
SIEMENS Supplementary Requirement for Core Reflood (continued)
. Initially, a very conservative value of per assembly was used j
The entrained liquid flow requirement was based on l
COBRA-TF simulations of experiments from the SPC Fuel Cooling l
Test Facility (FCTF) and included an estimated factor of conservatism l
i The supplementary requirement ensured conservative analysis
[
results until additional data was available to fully justify the use of l
RELENT alone l
i t
e
'!2'19 1 MEG.97403
SIEMENS Supplementary Requirement for i
Core Reflood (continued) i At the time the value was established internally, it was i
recommended that additional experimental data be obtained to justify a more realistic value
. Based on recently reduced (July 1996) experimental data, an t
absolute entrained liquid flow rate of was established to supplement the approved relative entrainment criterion For an ATRIUM
-98 fuel assembly, the revised entrained flow rate
)
is equivalent to about
. This entrained liquid flow rate was the lowest value used in the test series and was sufficient to cool the fuel rods.
i It is fully expected that a lower value of entrained liquid flow could be demonstrated to be sufficient based on future tests l
.A. $
SIEMENS Conservatism Introduced With the Use of the Supplementary Reflood Requirements i
. The following tables summarize results obtained from the sample problems presented in the EXEM BWR LOCA methodology topical reports and illustraw the level of conservatism introduced with both the original and revised supplementary reflood requirements
. The topical report does not discuss the use of a supplementary j
reflood requirement; however the sample problems presented included the supplementary requirement Changing the required supplementary requirement to the PCT for the sample problems but does not change the conclusions of the reports r
t l
SIEMENS Sample Problems From ANF-91 -048 Relative Criterion With Supplemental Reauirement BWR/3 Reflood Time (s)
PCT ( F)
APCT ( F)*
BWR/4 Reflood Time (s)
PCT ( F)
APCT ( F)*
BWR/6 Reflood Time (s)
PCT ( F)
APCT ( F)*
Relative to using only the approved reflood criterion mo,'C
I SIEMENS Sample Problems From ANF-91-048 Supplement 1 Relative Criterion With Supplemental Reauirement BWR/5 Reflood Time (s)
PCT ( F)
APCT ( F)*
BWR/5 Reflood Time (s)
PCT ( F)
APCT ( F)*
Relative to using only the approved reflood criterion 1/21#97 12 MEG 97003
SIEMENS Summary
. SPC plans to continue to determine core reflood time based on the relative entrainment reflood criterion originally used in the EXEM BWR LOCA methodology supplemented by a required absolute entrained liquid flow rate at the plane of interest
. The supplementary requirement is established based on experimental data to provide a conservative upper bound for the amount of entertained liquid flow required to provide adequate cooling 7
. The supplementary requirement on the entrained liquid flow introduces conservatism in the calculated PCT relative to the PCT calculated using the original reflood criterion alone j
i l
was. 3
SIEMENS i
Summary (continued?
This revised supplementary reflood requirement is being used in LOCA analyses to support the introduction of ATRIUM
-9 fuel at and ATRIUM
-10 fuel at For the use of the overly conservative l
supplementary requirement would result in t
For the use of the overly conservative supplementary requirement would result in flexibility 1
uea s
SIEMENS MCPR Safety Limit Evaluation
\\
Jerry G. Ingham
\\\\
Staff Engineer, BWR Safety Analysis s
l l
l I
in/97 (JGI-IN)01.97)
SIEMENS MCPR Safety Limit Evaluation
- Performed for each plant on a cycle specific basis
- Uses approved methodology - ANF-524(P)(A), Revision 2
- Input includes additive constants for each fuel design 1
i 2
ins 7 (JGI-P001.97)
SIEMENS MCPR Safety Limit Evaluation
- Susquehanna Unit 2, Cycle 9 model includes 312 assembliss of ATRIUM
-10* and 452 assemblies modeled as 9x9-2
- The revised additive constants for the ATRIUM-10 were used in the analysis
- The safety limit is with 0.0772% rods in boiling
[
I transition ( < 0.10%>
- ATRIUM is a trademark of Siemens 3
1/7/97 (JGI-IWil.97)
stEMENS i
r i.
FCTF Teseng for BWR Refl00d Criteri
\\
i
(
\\
Th0M86 H' KeheleY
\\
Statt En9 neerF g palysis Methods 1
\\
\\
\\'
\\
g l
1 117/9F THK 97.001
i SIEMENS FCTF Testing for BWR Reflood Criteria
. In 1990, Siemens Power Corporation performed BWR spray heat transfer tests in the Fuel Cooling Test Facility (FCTF) for the 9x9 internal canister fuel designs.
. As part of the spray heat transfer test program, entrainment tests were also performed.
. The test assembly was a full size 9x9 test bundle with indirect electrically heated rods and a 1.4 peak to average axial power profile.
[
]
2 sinst vm.srooi
4 9
6 e
C*~e I
b r;-
a J
}
C-E :
6
(- E,'
f I
m'
=
r, 3
Ie
=
q~.8 s.
, _J g:
g f
.a r
d
'l :
2 i
1 I
i) 8 s r~-
1:
v,::l : CW
?
I i
8 i
i.
l 2
l i
I,
(-r, ; (a ;
i i
s I
x l
.i
>1 i
i l
N* l-i---C)<,
E i
l l
i c
'IN -
N, i
?
l N,
7 l
- E l,,
I l f
t*
l (1
=
'f
\\ @ * '., e=.
== _.m
,,$~es r ^
7
==
=__=====e=====mia=-
=======_ma
't \\ ~
l j[
~
g l
/
/
- i r
I I
-m
~
i U
i i
=
x e
\\ l ;_
i i
a i d _,
it i
=.n
' 'V l--. _,
~-
l v-J E
W v
A i
E /
2 /
I I
l i
-/
I f
s 7
I
{-1s i
1 A
l 6<
i V:!!,.
N
/\\.
r l
<k V.
j i
4 i
I i
X l
m Z
1 5
l m
w 1
P l
6 o
u_
m i
i i
I e
\\
e l
SIEMENS FCTF Testing for BWR Reflood Criteria
. For the entrainment testing, water that was supplied by the reflood pump was sprayed into
].
. On the opposite side of the [
] steam was injected.
. Steam picked up a portion or all of the injected water and carried it through the bundle.
Power to the bundle was [
] throughout the test.
. The entrainment criteria was set on the amount of t
water available at the inlet to the bundle which caused the rod temperatures [
t l
l tmst im siooi
SIEMENS FCTF Testing for BWR Reflood Criteria l'
i I
117/97 1HK 97 001
SIEMENS FCTF Testing for BWR Reflood Criteria 1/7.97 THK.97.001
~~
SIEMENS FCTF Testing for BWR Reflood Criteria
SIEMENS FCTF Testing for BWR Reflood Criteria
SIEMENS FCTF Testing for BWR Reflood Criteria l
117197 THK.97 001
SIEMENS 1
FCTF Testing for BWR Reflood Criteria i
4 f
t 6
6
?
l I
'o u m i nm.sr.ooi i
i SIEMENS
)
1 i
NRC/SPC Meeting on BWR Methodology January 9,1997 i
SIEMENS Purpose of Meeting
. Review the application of ANFB correlation for the ATRIUM-10 design to show the application to be consistent with the NRC approval
. Describe the reflood criteria application in BWR LOCA 1
analyses i
1 i
... 1' i
SIEMENS Agenda
. Introduction--HD Curet
. ANFB Application for ATRIUM-10--TH Keheley
- Safety Limit Analysis--JG Ingham
. BWR Reflood Criteria Application--ME Garrett
. Summary / Conclusions--HD Curet
' 'wf e a
^
SIEMENS ANFB for the ATRIUM-10 design
. SPC did not change or alter the ANFB methodology for the ATRIUM-10 fuel
. SPC established the additive constants on the most restrictive data
. The predicted margins to limits are more conservative than would be predicted with a modified ANFB correlation supported by all CHF test data i
i l
w -;,
SIEMENS.
SPC is using a supplementary reflood criterion
. SPC was concerned about the relative reflood criterion in FLEX and applied a supplementary, conservative quantitative criterion Based on entrainment tests, SPC proposes the use of a less conservative supplementary criterion
. Annual notification procedures are anticipated to be appropriate for reporting the reflood criteria change
.