. I November 7, 1996 I

i Southern Nuclear Operating Company. Inc. i ATTN: Mr. D. N. Morey Vice President  ;

Farley Project i P. O. Box 1295 Birmingham. AL 35201-1295 i

SUBJECT:

. PLANT PERFORMANCE REVIEW (PPR) - FARLEY On October 1. 1996, the regional staff completed the semiannual Plant i Performance Review (PPR) of Farley. The staff conducts these reviews for all I operating nuclear power plants to develop an integrated understanding of ,

safety performance. The results are used by regional management to facilitate i planning and allocation of inspection resources. The PPR for Farley involved  !

the participation of all technical divisions in evaluating inspection results J and safety performance information for the period from March 1996 through August 1996. PPRs provide regional management with a current summary of l licensee aerformance and serve as inputs to the NRC Systematic Assessment of. l Licensee )erformance (SALP) and senior management meeting (SMM) reviews.

This letter advises you of our planned inspection effort resulting from the Farley PPR review. It is provided in an attempt to minimize the resource impact on your staff and to allow for scheduling conflicts to be resolved in advance of inspection dates. The enclosure presents our inspection plan for the next six months. Specific dates are included for near term inspections.

Long term inspection dates will be announced prior to'the inspections and any scheduling conflicts will be resolved with your staff. The rational or basis for each inspection outside the core inspection program is provided so that you are aware of the reasons for em)hasis in these program areas. Resident-inspections are not listed due to t1eir ongoing and continuous nature. nor are Region based inspections which accomplish Resident Core Modules to compensate for Resid.ent Inspector absences due to training.

During each NRC inspection planned during this period, specific attention will continue to be given to the verification of-selected Updated Final Safety.

Analysis Re) ort (UFSAR) commitments. Applicable portion (s) of the-UFSAR that relate to t1e inspection activities will be reviewed and verification made that the UFSAR commitments have been properly implemented into plant

-practices, procedures and/or parameters.

9611150305 961107 PDR G

ADOCK 05000348 PDR g

\ \

\

SEOl

1 SNC 2 We will inform you of any changes to the inspection plari. If you have any j questions, please contact P., H. Skinner at (404) 331-6299.

Sincerely.

(Original signed by Pierce H. Skinner)

Pierce H. Skinner. Chief Reactor Projects Branch 2 l Division of Reactor Projects l

l Docket Nos. 50-348, 50-364 License Nos. NPF-2, NPF-8

Enclosure:

Inspection Plan cc w/ encl:

M. J. Ajiuni. Licensing i Services Manager, B-031 l.

Southern Nuclear Operating Company, Inc.

-42 Inverness Center Parkway Birmingham.-AL 35242 R. D. Hill. Jr.

General Manager. Farley Plant Southern Nuclear Operating l

Company. Inc.

P. 0. Box 470

! Ashford, AL 36312

J. D. Woodard L

Executive Vice President l Southern Nuclear Operating j

! Company Inc.

l P. O. Box 1295 Birmingham, AL 35201 State Health Officer l- Alabama Department of Public Health i l- 434 Monroe Street Montgomery AL 36130-1701 l

M. Stanford Blanton Balch and Bingham Law Firm P. O. Box 306 1710 Sixth Avenue North

Birmingham. AL 35201' cc w/ encl cont'd: (See Page 3) i 1

4 SNC 3 cc w/ encl: Continued Chairman Houston County Commission P. O. Box 6406.-

Dothan, AL 36302 Distribution w/ encl:

J. Zimmerman NRR H. Christensen, RII G. A. Hallstrom, RII PUBLIC NRC Resident Inspector U.S. Nuclear Regulatory Commission  !

7388 N State Hwy 95 l Columbia. AL 36319 l l

I I

I SEND TO PUBt TC 00CtplENT ROOM) l} YES NO OFFICE RII:0RP RI jf:0RS:EB- RII:0RS:MB RII:0RS:S{B RII:0RS:PS8 SIGNATURE TLJ.(Ji3kT U

NME RWWright:dka P1 kinnpr CCasto HChristensen PFredrickson Barr DATE 10 / 3 0 / 96 j /% 10 / 3 / 96 - 10 / $ / % Jenh( / 96 10 f / 96 COPY? @ NO / ES ) NO f

/ ESh NO M NO kES) NO [fES) NO j i ' "

SEND TO PUBL10 DOCUMENT R0(Pt? YES NO OFFICE R!l:0RS;0LHP~ \!!:0RP

. SIGNATURE -

NME TPeeb 5 EWMers f DATE 10 t h / 96 10 / 6 10 / /% 10 / / 96 10 / / 96 10 / /%

COPY? (YES) ' NO l VES NO \ YES NO VES NO YES NO YES NO UEFICIA RtLUKU LUPY UULLF1LN1 MM; A;\F-LtlitK.FPR i

FARLEY INSPECTION PLAN INSPECTION TITLE / PROGRAM AREA NUMBER OF PLANNED TYPE OF INSPECTION - BASIS PROCEDURE / INSPECTORS INSPECTION TEMPORARY DATES INSTRUCTION ,

IP 81700 Physical Security Program for 1 10/07/96 Core Inspection Power Reactors

[ PLANT SUPPORT - SI]

IP 37550 Engineering 2 10/07/96 Core Inspection

[ ENGINEERING - ENG] 1 10/21/96 Core Inspection IP 83750 Occupational Exposure 1 10/21/96 Core Inspection  !

[ PLANT SUPPORT - PS] .

GL 89-10 U2RF11 - Followup on Reset MOV 1 10/21/96 Regional Initiative Torque Switches & MOV Functional Testing

[ MAINTENANCE - SI]

IP 73753 Inservice Inspection 1 11/04/96 Core Inspection - U2RF11 -

[ MAINTENANCE - MNT] Inspect Charging Pump Casings for Cracks & Boric Acid Corrosion: plus ISI ,

IP 71707 Plant Operations 1 11/04/96 Core Inspection - Assist RI

[ PLANT OPERATIONS - OLHP] Staff IP 64704 Fire Protection Program 1 11/11/96 Core Inspection '

[ PLANT SUPPORT - SI]

i

o

-i I

FARLEY INSPECTION PLAN r

GL 95-03. EPRI Steam Generator Integrated 1 12/09/96 Regional Initiative - Assess Guidelines, & Inspection Conditions. of SGs for Long TS [ MAINTENANCE - MNT] Term Use. .

U2RF11 SG Eddy Current ,

Testing

  • IP 82301 Evaluation of Exercises for 1 12/09/96 Core Inspection - Biennial EP  !'

Power Reactors Exercise: FEMA Evaluated.

IP 82302 Review of Exercise Objectives 1 12/09/96  :

& Scenarios for Power Reactors  !

[ PLANT SUPPORT - PS)

TI 2515/132 Vehicle Barrier System (VBS) 1 02/03/97 Regional Initiative - Verify Implementation

[ PLANT SUPPORT SI]

IP 93801- Safety System Functional 5 02/03/97 Area of Emphasis Inspection. Architect / Engineer 02/17/97 Two weeks (01/20 & 01/27/97) ,

Inspection 02/24/97 preparation. four weeks  !

[ ENGINEERING - S&W CONTRACT] 03/10/97 onsite inspection. j Preparation for Initial Exams 3 03/10/97 Core Inspection i

[ PLANT OPERATIONS - OLHP] 1 Initial Examination Inspection 3 03/24/97 Core Inspection

[ PLANT OPERATIONS - OLHP]

IP 62700 Maintenance Implementation 1 04/14/97 Regional Initiative - Maint.  ;

[ MAINTENANCE - MNT] & Testing of Main Steam Relief IP 62706 Maintenance Rule Inspection 5 07/21/97 Regional Initiative - Assess Procedure Program.

[ MAINTENANCE - MNT]