Amend 237 to License DPR-59,revising TSs Re ATWS Recirculation Pump Trip Logic,Per 960530 Application
ML20134J140
Person / Time
Site: FitzPatrick 
Issue date: 11/07/1996
From: Bajwa S
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20134J142 List:
References
NUDOCS 9611150019
Download: ML20134J140 (7)


Text

__

pMk N

4 UNITED STATES f

j NUCLEAR REGULATORY COMMISSION A-WASHINGTON, D.C. 2006t@o01

%

  • s s * *,o 9

l POWER AUTHORITY OF THE STATE OF NEW YORK DOCKET N0. 50-333 l

l l

JAMES A. FITZPATRICK NUCLEAR POWER PLANT AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.237 l

License No. DPR-59

)

1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Power Authority of the State of New York (the licensee) dated March 30, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, l

the provisions of the Act, and the rules and regulations of the Comission-1 C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

l 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-59 is hereby amended to read as follows:

9611150019 961107 PDR ADOCK 05000333 P

PDR

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.237, are hereby incorporated in the license.

The licensee snall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance to be implemented within 30 days.

FOR THE NUCLEAR REGULATORY COMMISSION S. Singh Bajwa, Acting Director Project Directorate I-1 Division of Reactor Projects - I/II l

Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: November 7, 1996 4

l I

ATTACHMENT TO LICENSE AMENDMENT NO.237 i.

i FACILITY OPERATING LICENSE NO. DPR-59 DOCKET NO. 50-333 Revise Appendix A as follows:

Remove Paces Insert Paaes 76a 76a 76b 76c 1

77 77 i

s I

i

.i JAFNPP 1

IABLE 32-7 A1WS RECIRCULATION. PUMP _ TRIP _INSTRURIENTATION REQUIREIIENTE Minimum Number of Operable Instmment Chamels Per Trip

(

i

, rip Level Setting Appilcable Modes T

System (Notes 1 & 2)

Trip Function 2

Reactor Pressure - High s 1120 psig, or Run s 1155 psig (Note 3) 2 Reactor Water Level-Low Low z 126.5 in.

Run above TAF i

i e

l 1

l Amendment No.-EE9,237 r

76a

JAFf9P i

f TABLE 32-7 fcont'dl I

l ATWS RECIRCUI.ATION PUMP TRIP INSTRUMENTATION REN l

NOTES FOR TABLE 3.2-7 f

1.

There shall be two or tilpped trip systems for each Trip Function, except as provided for below:

a.

For each Trip F with one less thak the required minimurp number of operable instrument channels, place the inoperable instrument channel and/or its associated trip system in the tripped condition

  • writun 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. Otherwise, place the reactor in the start-up/ hot stan@y mode lwithin the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

l b.

For each Trip F with two or more channels less than the required minimum number of operable instrument channels:

1) Within one hou, verify sufficient instrument d.aiins remain operable or tripped
  • to maintain trip capability in the Trip Function, and j
2) Within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />,{ place the inoperable instrument divin(s) in one trip system and/or that trip system" in the tripped condition *, and
3) Within 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> ;, restore the inoperable instrument channel in the other trip system to an operable status.

i If any of these three condtions cannot be satisfied, place the reactor in the start-up/ hot stan@y mode within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

l t

i I

An inoperable rument channel or trip system need not be placed in the tripped condition where this would cause the Trip Function to occur. In thest cases, if the inoperabie instrument channel is not restored to operable status within the required time, place the l

reactor in the stajt-up/ hot standby mode withm the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

" This action applios to that trip system with the greatest number of inoperable instrument channels. If both systems have the same number of inopelable instrument d.ain6=, the ACTION can be applied to either trip system.

2.

When a channel is placed in an inoperable status solely for performance of required surveillances, entry into associated Limiting Conditions for Operistion and required actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Trip Function maintains ATWS RPT iratiation capeldlity.

Amendment No. 237 '

,i 76b

JAFNPP JABLE 3.2-7 (contd)

ATW5_BELQBGEAllpN PUt4ELIBE NOTES FOR TABLE 3.2-7 (cont.)

3.

The ATWS Reacw Pressure High Recirculation Pump Trip setpoint shall be s 1155 psig when either zero or one SRVs are out of service. The setpoint shaR be s 1120 psig whyn two or more SRVs are out of service.

I I

Amendment No.

237 76c

JAFNPP 4

THIS PAGE INTENTIONALLY BLANK Amendment No. 07, 00,110,13',1 0, 227, 237 77

-