Amend 175 to License DPR-20,allowing one-time Deferral of Insp of Reactor Coolant Pump Flywheels from Cycle 12 Refueling Outage Scheduled to Begin on 961102
ML20134H646
Person / Time
Site: Palisades 
Issue date: 11/07/1996
From: Robert Schaaf
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20134H647 List:
References
NUDOCS 9611140207
Download: ML20134H646 (3)


Text

a J-4 --

' f nh N

g 4

UNITED STATES s

g

)FI j

NUCLEAR REGULATORY COMMISSION o

'2 WASHINGTON, D.C. 2066H001 CONSUMERS POWER COMPANY DOCKET NO. 50-255 PALISADES PLANT AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 175 License No. DPR-20 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Consumers Power Company Jthe licensee) dated August 14, 1996, as supplemented October 28,1996, and January 18 1996 complies with the standards and requirements oftheAtomicEnergy,Actof1954,asamended(theAct),andthe Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; There is reasonable assurance (i)d without endangering the health C.

that the activities authorized by this amendment can be conducte 4

and safety of the public; and i i ) that such activities will be conducted in compliance with th(e Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; E.

The issuance of this amendment is in accordance with 10 CFR 4

Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to the license amendment 1

and Paragraph 2.C.(2)llows:of Facility Operating License No. DPR-20 is hereby amended to read as fo The Technical Specifications contained in Appendix A as revised through Amendment No.175, and the Environmental Profection Plan contained in Appendix B are hereby incorporated in the license.

CPCo shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of the date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION J

$wp Robert G. Schaaf, Pro 1ect Manager Project Directorate IlI-1 e

9611140207 961107 Division of Reactor Projects - III/IV DR ADOCK 0500 5

p Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

November 7, 1996

1 ATTACHMENT TO LICENSE AMENDMENT NO. 175 FACILITY OPERATING LICENSE NO. DPR-20 i

DOCKET NO. 50-255 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the attached pages. The revised pages are identified by amendment number and contain vertical lines indicating the areas of change.

REMOVE INSERT 6-8 6-8 4

-~

'LO ADMINISTRATIVE CONTROLS i

6.5.5 Reserved i

t I

4 i

f 6.5.6 Primary Coolant Pi=a Flywheel Surveillance Proaram l

Surveillance of the primary coolant pump flywheels shall consist of a 1005 volumetric inspection of the upper flywheels each refueling *.

i i

6.5.7 Inservice Insoection and Testina Procram This program provides controls for inservice inspection and testing of ASME Code Class 1, 2, and 3 components including applicable supports.

The program shall include the following:

a.

Testing frequencies specified in Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda (B&PV Code) as follows:

B&PV Code terminology Required interval for inservice testing for performing inservice activities testina activities Weekly s

7 days Monthly s 31 days Quarterly or every 3 months s 92 days Semiannually or every 6 months s 184 days Every 9 months s 276 days Yearly or annually 5 366 days Biennially or every 2 years s 731 days b.

The provisions of Surveillance Requirement 4.0.2 are applicable to the above required intervals for performing inservice testing activities; The provisions of Surveillance Requirement 4.0.3 are applicable c.

to inservice testing activities; and d.

Nothing in the B&PV Code shall be construed to supersede the requirements of any Technical Specification.

The volumetric examination of the upper primary c6nlant pump flywheels is not required during the refueling outage at the end of cycle 12.

6-8 Amendment No.174,175