ML20134G929

From kanterella
Jump to navigation Jump to search
Forwards Special Insp Team Rept 70-1113/96-12 on 961204-08 & Notice of Violation
Date released: 05/27/2020 Download: ML20134G929


Special Insp Team Rept 70-1113/96-12 on 961204-08.Violations Noted.Major Areas Inspected:Circumstances Surrounding Tube Failure,Precursors to Event & Response to Event
ML20134G985
Person / Time
Site: 07001113
Issue date: 01/28/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20134G985 (24)
Notice of Violation from Insp on 961204-08.Violation Noted: on 961130,engineered Control Associated W/Line 3 Calciner Tube Failure Did Not Detect Undesired Situation & Was Not Capable of Performing Criticality Safety Purpose Specified
ML20134G956
Person / Time
Site: 07001113
Issue date: 01/28/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20134G956 (3)
Forwards Special Insp Team Rept 70-1113/96-12 on 961204-08 & Notice of Violation
ML20134G927
Person / Time
Site: 07001113
Issue date: 01/28/1997
From: Mallett B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: KIPP C P
GENERAL ELECTRIC CO.
References
Download: ML20134G927 (3)