SUBJECT:
SAFETY EVALUATION OF THE POWER / FLOW EXCLUSION REGION CALCULATION l
METHOD USING THE LAPUR5 COMPUTER CODE AND IMPLEMENTATION OF THE SOLOMON STABILITY MONITOR FOR VERMONT YANKEE NUCLEAR POWER STATION (TAC NO. M94207)
Dear Mr. Reid:
By letter dated October 31, 1995, as supplemented on November 3, 1995, Vermont Yankee Nuclear Power Corporation submitted a validation report, YAEC-1926,
" Method for Power / Flow Exclusion Region Calculation Using the LAPUR5 Computer Code," which is Yankee Atomic Electric Company's application of Boiling Water l
Reactor Owners Group (BWROG) stability exclusion region methodology for j
implementation of long-term solution Option 1-D at Vermont Yankee Nuclear Power Station (VYNPS). As discussed in the enclosed safety evaluation (SE),
l l
the NRC staff finds that (1) the proposed method for power / flow exclusion region calculation using the LAPURS computer code, and (2) the VYNPS implementation of the SOLOMON stability monitor are acceptable. The NRC l
staff's SE is based, in part, on the attached technical evaluation report (TER) by Oak Ridge National Laboratory.
Prior to incorporating a power / flow exclusion region calculated by this methodology into the plant Core Operating Limits Report, this approved methodology should be referenced in the plant Technical Specifications.
i Sincerely, ORIGINAL SIGNED BY:
C. Craig Harbuck, Acting Senior Project Manager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket No. 50-271
Enclosure:
Safety Evaluation w/ attached TER
)
cc:
See next page j
DISTRIBUT10H:
~Doctet File-JZwolinski OGC RJones PUBLIC SBajwa ACRS PDI-1 Reading Slittle LDoerflein, RGN-I SV.trga CHarbuck THuang DOCUMENT NAME: G:\\ VERMONT \\VY94207.LTR 4
To receive a copy of this document, indicate in the box:
"C" - Copy without j
attachment / enclosure "E" - Copy with attachment / enclosure "N" - No copy 0FFICE PM:PDI 1 lE LA:PDI-1 y L l
0:PDI-1 j pg l BC:SRXB lN l
SLittle SBajwa J f f RJones" [ n f..
NAME CMarbuck:rst,p[
DATE 10/h /%
UI O 10/ /A/%
10/ f/%"
1$/p< /% 6 10/ /%
cial Record Copy 9611080207 961105 PDR ADOCK 05000271 l
P PDft
a ccruq k
UNITED STATES g
I y
j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20066-0001 4 %,4 Noveraber 5,1996 Mr. Donald A. Reid Vice President, Operations Vermont Yankee Nuclear Power Corporation l
Ferry Road l
Brattleboro, VT 05301 l
SUBJECT:
SAFETY EVALUATION OF THE POWER / FLOW EXCLUSION REGION CALCULATION l
METHOD USING THE LAPURS COMPUTER CODE AND IMPLEMENTATION OF THE SOLOMON STABILITY MONITOR FOR VERMONT YANKEE NUCLEAR POWER STATION (TAC N0. M94207)
Dear Mr. Reid:
By letter dated October 31, 1995, as supplemented on November 3, 1995, Vermont Yankee Nuclear Power Corporation submitted a validation report, YAEC-1926, j
" Method for Power / Flow Exclusion Region Calculation Using the LAPUR5 Computer Code," which is Yankee Atomic Electric Company's application of Boiling Water Reactor Owners Group (BWROG) stability exclusion region methodology for implementation of long-term solution Option 1-D at Vermont Yankee Nuclear Power Station (VYNPS). As discussed in the enclosed safety evaluation (SE),
the NRC staff finds that (1) the proposed method for power / flow exclusion region calculation using the LAPUR5 computer code, and (2) the VYNPS implementation of the SOLOMON stability monitor are acceptable. The NRC staff's SE is based, in part, on the attached technical evaluation report (TER) by Oak Ridge National Laboratory.
Prior to incorporating a power / flow exclusion region calculated by this methodology into the plant Core Operating Limits Report, this approved methodology should be referenced in the plant Technical Specifications.
Sincerely, I
?
U C-C. Craig Harbuck, Acting Senior Project Manager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket No. 50-271
Enclosure:
Safety Evaluation w/ attached TER cc: See next page f
l
i 1
l i-D. Reid Vermont Yankee Nuclear Power Station Vermont Yankee Nuclear Power Corporation cc:
Regional Administrator, Region I G. Dana Bisbee, Esq.
U. S. Nuclear Regulatory Commission Deputy Attorney General 475 Allendale Road 33 Capitol Street King of Prussia, PA 19406 Concord, NH 03301-6937 R. K. Gad, III Resident Inspector Ropes & Gray Vermont Yankee Nuclear Power Station One International Place U.S. Nuclear Regulatory Commission Boston, MA 02110-2624 P.O. Box 176 Vernon, VT 05354 Mr. Richard P. Sedano, Commissioner Vermont Department of Public Service Chief, Safety Unit 120 State Street, 3rd Floor Office of the Attorney General Montpelier, VT 05602 One Ashburton Place, 19th Floor Boston, MA 02108 Public Service Board i
State of Vermont Mr. David Rodham, Director 120 State Street ATTN: James Muckerheide Montpelier, VT 05602 Massachusetts Civil Defense Agency 400 Worcester Rd.
Chairman, Board of Selectmen P.O. Box 1496 Town of Vernon Framingham, MA 01701-0317 P.O. Box 116 Vernon, VT 05354-0116 Mr. Raymond N. McCandless Vermont Division of Occupational Mr. Jay Thayer, Vice President and Radiological Health Vermont Yankee Nuclear Power Administration Building Corporation Montpelier, VT 05602 Ferry Road Brattleboro, VT 05301 Mr. J. J. Duffy Licensing Engineer Vermont Yankee Nuclear Power Corporation 580 Main Street Bolton, MA 01740-1398 Mr. Robert J. Wanczyk, Plant Manager Vermont Yankee Nuclear Power Station P.O. Box 157, Governor Hunt Road Vernon, VT 05354 Mr. Ross B. Barkhurst, President i
l Vermont Yankee Nuclear Power Corporation j
Ferry Road Brattleboro, VT 05301
.