k MaineVankee e

RELI ABLE ELECTRICl'Y SINCE 1972 329 BATH ROAD + BRUNSWICK, MAINE 04011 = (207) 7984100 1

4 E

November 1,1996 MN-96-158 JRH-96-239 4

i UNITED STATES NUCLEAR REGULATORY COMMISSION Attention: Document Control Desk Washington, DC 20555

References:

(a)

License No. DPR-36 (Docket No. 50-309)

(b)

Letter From Maine Yankee to NRC, dated October 3,1996 (MN-96-150)

Subject:

Containment High Range Radiation Monitor Gentlemen:

Reference (b)is a nctification that the A Train Containment High Range Radiation Area Monitor, RM-6113A, was declared inoperable on September 26,1996, due to spiking. The monitor was removed from service; the control module was inspected and cleaned; and the unit was placed back in service for trending purposes only.

On October 25,1996, an operability determination was performed and the unit was declared operable. There has been no further spiking, monitor indication and response has been normal, j

and daily checks of the monitor have been satisfactory.

A spare monitor has been ordered.

Very truly yours, M

8 James R. Hebert, Manager Licensing & Engineering Support Department JRH/mwf Enclosure

~

c:

/Mr. Hubert Miller h

0 Mr. J. T. Yerokun Mr. Daniel H. Dornan Mr. Patrick J. Dostie p n.-.

Mr. IIMis Vanaps 9611000063 961101 PDR ADOCK 05000309 P