ML20134C737

From kanterella
Jump to navigation Jump to search
Forwards Staff Evaluation Rept for Review of Plant IPE for Internal Events & Internal Floods & Listed TERs
Date released: 05/27/2020 Download: ML20134C737


Forwards Staff Evaluation Rept for Review of Plant IPE for Internal Events & Internal Floods & Listed TERs
ML20134L448
Person / Time
Site: Wolf Creek 
Issue date: 11/18/1996
From: Stone J
NRC (Affiliation Not Assigned)
To: CARNS N S
WOLF CREEK NUCLEAR OPERATING CORP.
References
Download: ML20134L448 (12)
Technical Evaluation Rept on IPE Submittal Human Reliability Analysis,Final Rept.
ML20134C742
Person / Time
Site: Wolf Creek 
Issue date: 09/05/1996
From: Wreathall J
JOHN WREATHALL & CO., INC.
To:
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
References
CON-NRC-04-91-069, CON-NRC-4-91-69
Download: ML20134C742 (39)
Technical Evaluation Rept of Wolf Creek Individual Plant Examination Back End Submittal,Final Rept,Nov 1995.
ML20134C738
Person / Time
Site: Wolf Creek 
Issue date: 11/30/1995
From: Vijaykumar R
ENERGY RESEARCH, INC.
To:
NRC
References
CON-NRC-04-91-068, CON-NRC-4-91-68
Download: ML20134C738 (36)
Technical Evaluation Rept on Individual Plant Examination Front End Analysis for Wolf Creek Generating Station Task 44
ML20134C735
Person / Time
Site: Wolf Creek 
Issue date: 11/28/1995
From: Thomas W
SCIENCE & ENGINEERING ASSOCIATES, INC.
To:
NRC
References
CON-NRC-04-91-066, CON-NRC-4-91-66
Download: ML20134C735 (51)