Text

- _.,

-, _ - - ~. - -

~

I

,.4 VERMONT YANKEE NUCLEAR POWER CORPORATION i

REPLY To I

ENGINEERING OFFICE l

680 MAIN STREET e-P.O. Box 157, Governor Hunt Road 80'* M^ 0'78

(

Vernon, Vermont 05354-0157 j

v (802) 257-7711 l

January 27,1996 l

BVY-97-13 i

l 1

l l

U.S. Nuclear Regulatory Commission l

Attention: Document Control Desk Washington, D.C. 20555 i

i l

References:

a) License No. DPR-28 (Docket No. 50-271)

Subject:

Vermont Yankee 1996 Summary Reports for Inservice Inspecbon and Repairs and Replacements.

i I

In accordance with Article IWA-6000 of Section XI of the ASME Boiler and Pressure Vessel Code, we hereby submit the Vermont Yankee Owner's Report for Inservice Inspections (Form NIS-1) and the Owner's Report for Repairs or Replacements (Form NIS-2). These reports describe the inservice Examinations and repairs and replacemento performed during the period frem May 3,1995 through November 2,1996 (including RFO 19). Vermont Yankee's third ten-year interval began September 1, 1993.

We trust that the informatior provided is adequate; however should you have any questions or require additional information, please do not hesitate to contact us.

Sincerely, Vermont Yankee Nuclear Power Corporation

[

E. V. Lindamood 030010 Directorof Engineering cc:

USNRC Regional Administrator USNRC Resident inspector-VYNPS USNRC Project Manager-VYNPS Inspection Agency-Arkwright I

t 970203o053 970127

}

PDR ADOCK 0500 1

G j