ML20134A718

From kanterella
Jump to navigation Jump to search
Provides Info Which Consists of PCT Data for Limiting Transient Analysis for Small & Large Break LOCA Evaluation Models to Meet Annual Reporting Requirements for 10CFR50.46 for 1996
ML20134A718
Person / Time
Site: Maine Yankee
Issue date: 01/16/1997
From: Hebert J
Maine Yankee
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
JRH-97-20, MN-97-14, NUDOCS 9701290066
Download: ML20134A718 (5)


Text

MaineYankee RELIABLE ELECTRICITY SINCE 1972 329 BATH ROAD + BRUNSWICK. MAINE 04011 * (207) 798-4100 January 16,1997 MN-97-14 JRH-97-20 UNITED STATES NUCLEAR REGULATORY COMMISSION Attention: Document Control Desk Washington, DC 20555

References:

(a)

License No. DPR-36 (Docket No. 50-309)

(b-o) Please see the attached

Subject:

1996 Annual Report in Accordance with 10CFR50.46(a)(3)(ii) for Maine Yankee Gentlemen:

Maine Yankee is providing the following information in accordance with 10CFR50.46, Reference (b). This information which consists of PCT data for the limiting transient analysis for the Small and Large Break LOCA evaluation models is being provided to meet the annual reporting requirements of 10CFR50.46 for the year 1996.

The present small break evaluation model for Maine Yankee includes the following method:

Combustion Engineering's Small Break LOCA Method as applied in Cycle 4 to Maine Yankee as a base, with the impact of changes since that time on Cycle 15 at power levels up to 2440 MWt estimated by hand calculation.

This method is described in Reference (c) and (d) and was designated by the NRC for use on Maine Yankee in Reference (e).

The present Large Break Evaluation Model for Maine Yankee includes the following computer codes and methods:

YAEC WREM-based generic PWR ECCS Evaluation Model, modified to include modifications for Injection delta P, multiple axial power shapes, and enhanced steam cooling, and enhanced fuel performance methodology using the FROSSTEY-2 computer code. The computer codes used in this method include:

RELAP4 MOD 3 i

4 001 CONTEMPT LT026 TOODEE2-EM

,3 p q g l,,.3 FROSSTEY-2 c 0 t/ v This method is described in References (f-i) and approved by the NRC for use on Maine Yankee in References (j - m).

9701290066 970116 PDR ADOCK 05000309 R

PDR

MaineYankee UNITED STATES NUCLEAR REGULATORY COMMISSION MN-97-14 Attention: Document Control Desk Page 2 The most recent 50.46 report generated for the Small Break LOCA evaluation model was the Annual Report provided to the NRC January 18,1996, in Reference (d). The limiting transient for the small break analysis provided in Reference (d) had a maximum peak clad temperature of 1758 F. The present peak clad temperature for the limiting transient is 1806 F, including all changes since the last report. The change in peak clad temperature since the last report is 48"F. Changes that have been evaluated since this report include:

Increase in Steam Generator Hydraulic Resistance due to Tube Plugging / Sleeving The additional hydraulic resistance due to tube plugging / sleeving increases the time for the primary system to depressurize and hence a longer core uncovery. This effect was included in the original Cycle 15 analysis. The resultant change in PCT for this effect was less than 10 F. The increase in steam generator hydraulic resistance due to tube plugging / sleeving -

also results in a slightly earlier core uncovery due to the increased pressure drop between the core exit and the break. This effect was not included in the original Cycle 15 analysis. The calculated change in PCT resulting from this effect is 2 F for the limiting Small Break LOCA transient.

Main Steam Safety Valve (MSSV) Setpoint Assumption The Reference (d) analysis assumed nominal valve setpoints for the Main Steam Safety Valves with no allowance for valve accumulation. This assumption is consistent with the Cycle 4 CE analysis assumption (c). The accepted practice is to set these valves at 1% of their setpoint. Testing of these valves indicates that drift is minimal. The estimated increase in Small Break LOCA PCT resulting from variation in the MSSV setpoints and valve accumulation is 46 F. It should be noted that a new Small Break LOCA evaluation model analysis has been provided to the NRC in Reference (n). In this analysis bounding MSSV setpoints were assumed with allowance for valve accumulation. The Small Break LOCA evaluation model and analysis is presently under review at the NRC.

The cumulative (absolute value) change in the limiting small break transient peak clad temperature based on the evaluated changes is 48 F. Table I summarizes the PCT changes for the limiting small break LOCA transient.

The most recent 50.46 report generated for the Large Break LOCA evaluation model was the 30 Day Report provided to the NRC September 20,1996, in Reference (o). This 30 Day Report provided results from the new analysis of record, using the Large Break LOCA evaluation model, References (f-i). No changes have been made to the Large Break LOCA analysis since the 30 Day Report was i

issued. Therefore, the previous peak clad temperature for the limiting transient of 2144 F is unchanged for this annual report and thus there is no change in PCT for the Large Break LOCA for this annual report. Table I summarizes that there are no PCT changes for the limiting Large Break LOCA transient using the evaluation model described in References (f-i), since the last 50.46 report, Reference (o).

MaineYankee

\\

UNITED STATES NUCLEAR REGULATORY COMMISSION MN-97-14 l

Attention: Document Control Desk 1

Page 3 1

i

\\

We trust this information is satisfactory; however, should you have any questions, please do not l

hesitate to contact us.

2 Very truly yours,

]

ames R. Hebert, Manager

)

Licensing & Engineering Support Department i

JRH 4

I Attachments j

c:

Mr. H. J. Miller Mr. J. T. Yerokum Mr. D. Dorman j

]

Mr. Patric J. Dostie i

Mr. Uldis Vanags 4

}

4 l

l MN-97-14 i

TABLE 1 Limiting LOCA Transient PCT Summary for Large and Small Break ECCS Evaluation Models l

Description Peak Clad Temperature is the Change j

or an Estimate Change in Peak Clad Requiring a 3

}

Temperature Schedule for Reanalysis?

4 3

Small Break LOCA Evaluation Model 1

Previous peak clad temperature for the limiting transient. (This is 1758*F NA the PCT for the limiting transient from last Analysis of Record from the last 50.46 Report.)

Present peak clad temperature for the limiting trans ent. (This is the 1806*F NA PCT for the limiting transient from the new analysis of record or latest PCT estimate.)

Change in Peak Clad Temperature from previous to present limiting 48*F NA transient Change due to increased hydraulic resistance in the t. team generators 2*F No from increased tube plugging Change due to MSSV setpoint assumption 46*F No*

Cumulative (Absolute Value) Change in Peak Clad Temperature 48'F NA Since Last 50.46 Report Cumulative (Absolute Value) Estimated Change in Peak Clad 46*F NA Temperature Since Last Analysis of Record Large Break LOCA Evaluation Model Previous peak clad temperature for the limiting transient. (This is 2144*F NA the PCT for the limiting transient from last Analysis of Record from the last 50.46 Report.)

Present peak clad temperature for the limiting transient.

2144*F NA (Unchanged, since there has been no new analysis since the last 50.46 report, Reference (b).)

Change in Peak Clad Temperature from previous to present limiting None, since there has been no new NA transient analysis since the last 50.46 report, Reference (o).

Change or Error since last analysis of record None NA Cumulative (Absolute Value) Change in Peak Clad Temperature None NA Since Last 50.46 Report Cumulative (Absolute Value) Estimated Change in Peak Clad None NA Temperature Since Last Analysis of Record

  • A new analysis has already been provided to the NRC in Reference (n).

l

MN-97-14

References:

(b) 10CFR50.46: Acceptable Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors j

(c)

Letter, Maine Yankee to USNRC, WMY 77-87, dated September 22,1977 (d)

MY Letter to USNRC dated January 18,1996 (MN-96-06)- Revision 2 of the Cycle 15 Core Performance Analysis Report and 10CFR50.46 Report (e)

USNRC Letter, William T. Russell to C. D. Frizzle, Confirmatory Order Suspending Authority for and Limiting Power Operation and Containment Pressure (Effective 4

Immediately) and Demand for Information (TAC No. M94194), dated January 3,1996 (f)

YAEC-1160, Application of Yankee WREM-BASED Generic PWR ECCS Evaluation Model to Maine Yankee, July 1978 (g)

Letter, G. D. Whittier (MYAPC) to A. C. Thadani (NRC), MN-86-141, dated November 10,1986 (h)

Letter, G. D. Whittier (MYAPC) to V. Nerses (NRC), MN-87-59, Maine Yankee LOCA Analysis, dated May 21,1987 (i)

YAEC-1912P-A, Methods for the Analysis of Oxide Fuel Rod Steady-State Thermal Effects (FROSSTEY-2), January 1995 (Proprietary)

(j)

Letter R. W. Reid (NRC) to R. H. Groce (MYAPC), Review of Application of Yankee WREM-Based Generic PWR ECCS Evaluation Model to Maine Yankee (3-Loop Sample Problem), dated January 17,1979 (k)

Letter P. R. Sears (NRC) to J. B. Randazza (MYAPC), NMY-87-1, ECCS Evaluation Model Modifications Related to Axial Power Shape Issue, Phase I, and Enclosed Safety Evaluation, dated January 6,1987 (1)

Letter NRC to Maine Yankee, NMY 88-84. Evaluation of Maine Yankee Steam Cooling Model for Large Break, Tac. No. 65463, dated June 28,1988 (m)

Letter NRC to Vermont Yankee, NVY 92-178, Vermont Yankee Nuclear Power Station, Safety Evaluation of FROSSTEY-2 Computer Code (Tac. No. M68216), dated September 24,1992 (n)

Letter, C. D. Frizzle (MYAPC) to W. T. Russell (USNRC), Submittal of Maine Yankee

}

SBLOCA Licensing Analysis in Compliance with 10 CFR 50.46 and in Satisfaction of TMI Action Items II.K.3.30, II.K.3.31, and II.K.3.5, MN-96-056, dated April 25,1996 (o)

MY letter to USNRC dated September 20,1996 (MN-96-139)- 10CFR 50.46 Report -

i Change in Calculated Peak Fuel Cladding Temperature (PCT) c 1