ML20134A093

From kanterella
Jump to navigation Jump to search
Submits Info Re Item of Noncompliance 1 from Insp Repts 50-293/81-18 50-293/81-22,per 850730 Telcon.Listed Activities Will Provide Adequate Technical Guidance & Tech Spec Refs
ML20134A093
Person / Time
Site: Pilgrim
Issue date: 08/07/1985
From: Harrington W
BOSTON EDISON CO.
To: Ebneter S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
85-142, NUDOCS 8508150185
Download: ML20134A093 (2)


Text

F~

l l

EOSTON EDISON COMPANY S00 SOvLsTON STREET SOsTON, MAssAcNusETTs 02199 WILLIAM D. NARRINGTON j

u............

August 7, 1985 BECo Ltr. #85-142 Mr. Stewart D. Ebneter, Director Division of Reactor Safety U.S. Nuclear Regulatory Commission Region I - 631 Park Avenue Ming of Prussia, PA 19406 License No. DPR-35 Docket No. 50-293

Subject:

Followup Information Relating to INC 81-22-01

Reference:

Combined NRC Inspections 81-18 and 81-22

Dear Mr. Martin:

Per Boston Edison Company's telephone conversation on 7/30/85 with Mr. Jack Durr of your office, we are providing you with the following information relating to Item of Non-Compliance 81-22-01:

In order to enhance the affected Station operating procedures to the point where those procedures will provide the user adequate technical guidance and Tech. Spec. section references, the below-listed activities will be funded, staffed, and completed as follows:

Scheduled Activity Description Completion Date Revise pro'cedures for D4, DS, D6, Yl, Y2, 12/31/85 and D19 to more clearly indicate equipment affected by the individual breakers.

Complete E-203 walkdowns and issue Discrepancy 7/31/86 packages to the Nuclear Engineering Dept.

for disposition.

Revise all affected procedures to include:

9/30/86

1) Applicable Technical Specifications
2) Walkdown-Observed Configuration Changes g t,g G-EM
3) Component Details p _ @ hi3 N

,, r.w.s l

gas 2222 8E%3 P

D I b

Q--

I

' BOSTON EDISON COMPANY Mr. Steward D. Ebneter U.S. Nuclear Regulatory Commission August 7,1985 Page Two We trust that this information will provide the details and conterit required.

However, if you have any further questions regarding these issues, please do not hesitate to contact me.

Very truly yours, 1

-.aX

, -. q,,

W. D. Harrington