ML20133Q240

From kanterella
Jump to navigation Jump to search
Informs of Completion of Review of Draft Staff Technical Position on Testing & Insp Plans During Const of DOE Remedial Action at Inactive U Mill Tailing Sites.Section 3.2.3 Deserves Further Attention
ML20133Q240
Person / Time
Issue date: 08/01/1985
From: Rich Smith
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Higginbotham L
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
REF-WM-39 NUDOCS 8508150069
Download: ML20133Q240 (2)


Text

1

. SsA UNITED STATE 3 p rerg%

4 NUCLEAR REGULATORY COMMISSION 0%

a.,

M DOCKET CONTROL CENTER URANIUM RECOV FIELD OFFICE I

DENVER, COLORADO 80225 WM Record Fi!e WM Pro 85 A!E -5 A10:57 Decket No. _

AUG 011985 PDR /

LPOR _-__

_DJstri' utyp __

URF0:GCP c

REG 2 j$//

.D2it)_.g'tO3ugnDU--&}lIn

. _ _ _... 023 3S)

(Rdu.ntopl.

MEMORANDUM FOR:

Leo B. Higginbotham, Chief Low-Level Waste and Uranium Recovery Projects Branch Division of Waste Management FROM:

R. Dale Smith, Director Uranium Recovery Field Office, Region IV

SUBJECT:

URF0 REVIEW 0F DRAFT STAFF POSITION ON TESTING AND INSPECTION DURING CONSTRUCTION OF DOE'S REMEDIAL ACTION Af INACTIVE URANIUM MILL TAILINGS SITES The Uranium Recovery Field Office (URFO) has completed its review of the

" Draft Staff Technical Position on Testing and Inspection Plans During Construction of DOE's Remedial Action at Inactive Uranium Mill Tailings Si tes. " Although the staff had no substantive problems with the position paper, one particular requirement was felt to be deserving of further attention, as noted in the following paragraph:

1.

Section 3.2.3, p. 6 The frequencies specified for routine field density testing of compacted materials appear high.

Both " Design of Small Dams" (Section 11.3d), and " Earth and Earth-Rock Dams" (Section E-4),

recommend a frequency of one test per 2,000 cubic yards of embankment fill placed for routine testing. While a higher frequency may be necessary for radon barrier or liner materials, the frequency recommended in the above references should be adequate for other compacted materials.

g50001 0%Ov

s

. Vg, 2-AUG 01 pggg We appreciate the opportunity to comment on this position.

If you have any questions, please contact George Pangburn at FTS 776-2813.

b

++

R. Dale Sm til, Dhector Uranium Recovery Field Office Region IV i

,.m,_

.re-w-

- - - - --