ML20133P693

From kanterella
Jump to navigation Jump to search

U.S. Nuclear Regulatory Commission Verification Letter for the Pressurized Water Reactor Owners Group Topical Report PWROG-17034, Revision 0, Evaluation of the WCAP-10325-P-A Westinghouse LOCA Mass & Energy Release Methodology
ML20133P693
Person / Time
Site: 99902037
Issue date: 05/15/2020
From: Dennis Morey
Licensing Processes Branch
To: Nowinowski W
PWR Owners Group, Westinghouse
Fields L
References
EPID L-2018-TOP-0013, PWROG-17034, WCAP-10325-P-A
Download: ML20133P693 (2)


Text

May 15, 2020 Mr. W. Anthony Nowinowski, Program Manager PWR Owners Group, Program Management Office Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066

SUBJECT:

U.S. NUCLEAR REGULATORY COMMISSION VERIFICATION LETTER FOR THE PRESSURIZED WATER REACTOR OWNERS GROUP TOPICAL REPORT PWROG-17034, REVISION 0, EVALUATION OF THE WCAP-10325-P-A WESTINGHOUSE LOCA MASS & ENERGY RELEASE METHODOLOGY (EPID L-2018-TOP-0013)

Dear Mr. Nowinowski:

By letter dated March 20, 2020 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML20083K085), the Pressurized Water Reactor Owners Group (PWROG) submitted an approval (-A) version of Topical Report (TR) PWROG-17034, Revision 0, Evaluation of the WCAP-10325-P-A Westinghouse LOCA [Loss-of-Coolant Accident] Mass & Energy [M&E] Release Methodology to the U.S. Nuclear Regulatory Commission (NRC). The PWROG has submitted the TR in accordance with NRCs request to publish an approval version of this TR, as detailed in NRCs transmittal letter for the final safety evaluation (ADAMS Accession No. ML20024E883) dated January 31, 2020.

The NRC staff has completed its review of the approval version of the TR (ADAMS Accession No. ML20083K090). The NRC staff verified that Westinghouse has met the requirements and determined that the submitted -A version is acceptable for referencing in licensing applications for nuclear power plants to the extent specified, and under the limitations delineated in the accepted version of the TR. PWROG-17034, Revision 0, is now acceptable for use in future licensing actions.

Please contact Leslie Fields of my staff at (301) 415-1186 if you have any questions on this subject.

Sincerely,

/RA/

Dennis C. Morey, Branch Chief Licensing Processes Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 99902037

ML20133P693 *Via e-mail OFFICE NRR/DORL/LLPB/PM* NRR/DORL/LLPB/LA* NRR/DSS/SNPB/BC* NRR/DSS/SRXB/BC*

NAME LFields DHarrison RLukes SKrepel DATE 05/13/2020 05/15/2020 05/13/2020 05/14/2020 OFFICE NRR/DORL/LLP/BC*

NAME DMorey DATE 05/15/2020