ML20133P082

From kanterella
Jump to navigation Jump to search
Correction to 850708 Amend to Order Modifying Certain Pages of Tech Specs.Corrected Table 3.6-2 Re Designation of Containment Penetrations R-573 & R-577 Encl
ML20133P082
Person / Time
Site: Crane Constellation icon.png
Issue date: 08/08/1985
From: Eisenhut D
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20133P078 List:
References
NUDOCS 8508140135
Download: ML20133P082 (4)


Text

_

UNITED STATES OF AMERICA NUCLEAR REGULATORY C0ttMISSION In the Matter of

)

)

GENERAL PUBLIC UTILITIES NUCLEAR

)

Docket No. 50-320 CORPORATION

)

)

(Three Mile Island Nuclear Station, )

Unit 2)

)

CORRECTION TO Af1ENDMENT OF ORDER On July 8,1985, the Director, Nuclear Reactor Regulation, issued an Amendment of Order to be effective August 12, 1985, modifying Section 1.7 and adding Table 3.6-2 to Appendix A Proposed Technical Specifications.

The changes pertained to containment penetration valve configurations.

Table 3.6-2 of Enclosure 3 of the July 8,1985 Amendment of Order contains two typographical errors in the identification of containment penetrations:

R-537 - Reactor Coolant Pump, and R-577 - Nuclear Services Closed Cooling Water to Reactor Coolant Pump 011 and Motor Coolers. The correct designation should be R-573 - Reactor Coolant Pump, and R-557 - Nuclear Services Closed Cooling Water to Reactor Coolant Pump Oil and Motor Coolers.

Accordingly, the Amendment of Order dated July 8,1985, is hereby corrected to incorporate the modifications set forth in Enclosure 1 hereto.

FOR THE NUCLEAR REGULATORY COMMISSION l

Da rre l I' la.

enhu,

puty Director L

Office of Nuclear Reactor Regulation Effective Date: August 12, 1985 Dated at Bethesda, Maryland Issuance Date: August 8, 1985 Nh h0 DO P

r-

.j TABLE 3.6-2 PENETRATIONS WITHOUT DOUBLE ISOLATION Penetration Function System R-573*

Reactor Coolant Pump MU R-574*

Seal Water Supply R-575*

R-576*

R-577*

Reactor Building Air RR R-579*

Unit Cooling Water R-584*

R-587*

R-580*

R-583*

Reactor Building Spray BS R-586*

Inlet Line R-589*

Decay Heat Coolant Supply DH R-590*

R-591*

High Pressure Injection MU R-592*

R-537*

Nitrogen and Fill to Core CF Flooding Tank R-539*

Leakage Cooling DC R-542*

Pressurizer Auxiliary Spray DH R-544*

Nitrogen and Fill to Core CF Flooding Tank R-557*

Nuclear Services Closed Cooling NS Water to Reactor Coolant Pump Oil and Motor Coolers R-559*

Intermediate Closed Cooling IC Water to Roller Nut Drive Cooling Coils R-563*

Intermediate Closed Cooling IC System R-566*

Service Air SA R-570*

High Pressure Injection MU R-572*

THREE HILE ISLAND - UNIT 2 3.6-4 August 12, 1985

_u d-e e..

A

_m.

h a

I J

e a

.t h

i l

i 1

l I

i 1

1 I

. - _ - _ _ _ _ _ _ ~

-.. _ _ _ - ~ _.

(

$ u.a. esvaasuant passtene erresas 1973-633 712 pn nauq$*.

f E

UNITED STATES 3

q NUCLEAR REGULATORY COMMISSION o,,

WASHINGTON, O C. 20555

%,.Y

,o August 8,1985 Docket No. 50-320 i

Docketing and Service Section Office of the Secretary of the Commission

SUBJECT:

Three Mile Island, Unit 2 Operating License No. DPR-73 Docket No. 50-320 Corrected Page for July 8,1985 Amendment of Order Two signed originals of the Federal Register Notice identified below are enclosed for your transmittal to the Office of the Federal Register for publication. Additional conformed copies (

)of the Notice are enclosed for your use.

O Notice of Receipt of Application for Construction Permit (s) and Operating License (s).

O Notice of Receipt of Partial Application for Construction Permit (s) and Facility License (s): Time for Submission of Views on Antitrust Matters.

O Notice of Availability of Applicant's Environmental Report.

O Notice of Proposed Issuance of Amendment to Facility Operating License.

O Notice of Receipt of Application for Facility License (s); Notice of Availability of Applicant's Environmental Report; and Notice of Consideration of Issuance of Facility License (s) and Notice l

of Opportunity for Hearing.

O Notice of Availability of NRC Draft l Final Environmental Statement.

O Notice of Limited Work Authorization.

O Notice of Availability of Safety Evaluation Report.

I I

O Notice of issuance of Construction Permit (s).

O Notice of Issuance of Facility Operating License (s) or Amendment (s).

^-indment nf neder nf.1oly_8JRG far

(

Q Other:_. Corrected Dann i

?

I

)

l h ! / R.tW h 4~

Bernard J. Snyder, Program Director Office of Nuclear Reactor Regulation

Enclosure:

As Stated i

i

~ - -

_ _ _ _ p eroau m __

.