ML20133K755

From kanterella
Jump to navigation Jump to search
Ack Receipt of 850129 Ltr Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-445/84-34 & 50-446/84-13.Addl Info Required for Item B.1 Re Falsification of Records & Corrective Measures Taken
Date released: 05/26/2020 Download: ML20133K755


Responds to NRC 841231 Ltr Re Violations Noted in Insp Repts 50-445/84-34 & 50-446/84-13.Corrective Actions:Safety Class Component Supports Reworked & Accepted & Quality Instruction QI-QAP-11.1-28A Deleted
ML20133K763
Person / Time
Site: Comanche Peak 
Issue date: 01/29/1985
From: Clements B
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: HUNTER D R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML20133K763 (5)
Ack Receipt of 850129 Ltr Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-445/84-34 & 50-446/84-13.Addl Info Required for Item B.1 Re Falsification of Records & Corrective Measures Taken
ML20133K752
Person / Time
Site: Comanche Peak 
Issue date: 10/16/1985
From: Denise R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: COUNSIL W G
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
References
Download: ML20133K752 (2)