ML20133K557

From kanterella
Jump to navigation Jump to search
Forwards Addl Info Re Generic Ltr 83-28,Position 3.2.2, Review of Test Recommendations & Guidance. Util Commits to Revise Nuclear Div Procedure NDP-100-3 to Require Review of Applicable safety-related Procedures When Required
ML20133K557
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 10/17/1985
From: Withers B
PORTLAND GENERAL ELECTRIC CO.
To: Butcher E
Office of Nuclear Reactor Regulation
References
GL-83-28, NUDOCS 8510220151
Download: ML20133K557 (2)


Text

_ _ _ _ _ _ _ _ - - _ _ _ .

-L m Wuuums

~W Bad D Wous Vce Presdert October 17, 1985 Trojan Nuclear Plant Docket 50-344 License NPF-1 Director of Nuclear Regulation ATTN: Mr. Edward J. Butcher, Jr., Acting Chief Operating Reactor Branch No. 3 Division of Licensing U.S. Nuclear Regulatory Comission Washington DC 20555

Dear Sir:

PGE Response to Request for Additional Information Relating to Generic Letter 83-28 In response to a recent telephone conversation with Lisa Lazo, NRC's Project Manager for the Trojan Nuclear Plant, additional information concerning Generic Letter 83-28 is provided in Attachment A.

Sincerely.

-_r Bart D. Withers Vice President Nuclear Attachment Subscribed and sworn to before me this 17th day of October 1985.

Wr O

Notary Public of diegon My Comission Aged Expires: [MM _

0 7

8510220151 851017 goa anoen oso g 4 @3 1

I e

Trojan Nuclear Plant Mr. Edward J. Butcher, Jr.

Docket 50-344 October 17, 1985 Licenso NPF-1 Attachment A PGE R2SPONSE TO REQUEST FOR ADDITIONAL INFORMATION ON GENERIC LETTER 83-28. POSITION 3.2.2 NRC Concern PGE's previous responses to Position 3.2.2, " Review of Test Recommenda-tions and Guidance", did not provide adequate assurance that vendor service bulletins and recommendations associated with all safety-related equipment not covered by Westinghouse had been properly considered for inclusion in Trojan procedures.

PGE Response In PGE's response to Position 3.2.2, dated July 19, 1985 PGE committed to review all safety-related technical manuals for accuracy and con-sistency and update the manuals, as necessary, by July 1987. In order to satisfy NRC concerns, 1:GE sucther commits to revise Nuclear Division Procedure NDP 100-3, Updating Technical Manuals, to require a review of applicable saft.ty-related procedures when a significant revision to a technical manual is required.

DRP/kal 0462W.1085