Text
Mr. Gary J. Taylor January 15, 1997 Vice President. h.kar Operations
' South Carolina Electric & Gas Company Virgil C. Sunmer Nuclear Station Post Office Bax 88 l
Jenkinsville, South Carolina 29065
SUBJECT:
IN5ERVICE TESTING PROGRAM, RELIEF FROM CODE ACCEPTANCE CRITERIA REQUIREMENTS OMA-1988, PART 6, SECTION 6.1, FOR CHARGING PUMP "A" VIRGIL C. SUMMER NUCLEAR STATION (TAC NO. M97314)
Dear Mr. Taylor:
By letter dated November 20, 1996, as supplemented on January 10, 1997, South Carolina Electric and Gas Company, the licensee for the Virgil C. Summer Nuclear Station, submitted a relief request proposing not to perform increased frequency testing on their "A" charging pump.
During substantial flow testing i
in accordance with the guidance in Generic Letter 89-04, Position 9, pump bearing vibration was observed to be in the alert range. The American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code requires j
the test frequency to be doubled when pump hydnulic or mechanical parameters enter the alert range as specified by the Code.
The licensee has proposed to perform a monthly vibration monitoring program of the pump until the 10th refueling outage when full-flow testing can be performed.
The U. S. Nuclear Regulatory Commission (NRC) has reviewed the proposed alternative referenced above against the requirements of Section XI of the ASME B&PV Code pursuant to paragraph 50.55a of Part 50 to Title 10 of the [ ode of Federal Reaulations. The results of the review are provided in the enclosed Safety Evaluation.
This completes TAC Number M97314.
Sincerely, (Original Signed By)
F. Mark Reinhart, Director (Acting)
Project Directorate 11-1
. Division of Reactor Projects - I/II Office of Nuclear Reactor' Regulation Docket No. 50-395
Enclosure:
Safety Evaluation-DISTRIBUTION:
Docket File ACRS PUBLIC GHill (4)
OGC EMerschoff, RII PD II-1 RF SVarga cc w/ encl:
See next page GTracy hh h i
II RWessman JColaccino f
AJohnson DOCUMENT NAME:
G:\\ SUM 97314.REL
- Previously Concurred To receive a copy of this document, indicate in the box:
"C" = Copy without attachment / enclosure "E" =
Copy with attachment / enclosure "N" = No copy OFFICE PM:PD2-1 E
LANs1 Ey C:EMEB' OGC*
PD:PD2-1 3
3 NAME AJohnson(
0 ton:
RWessman FMReinhart 4
01/N/97 01/N/97 01/13/97 01/14/97 01//s"/97 J
V DATE
\\0FFICIAL RECORD COPY 9701210049 970115 PDR ADOCK 05000395 P
Mr. Gary J. Taylor VIRGIL C. SWelER IEJCLEAR STATION South Carolina Electric & Gas Company I
cc:
4 Mr. R. J. White Nuclear Coordinator S.C. Public Service Authority c/o Virgil C. Summier Nuclear Station Post Office Box 88, Mail Code 802 3
Jenkinsville, Sou+h Carolina 29065
)
J. B. Knotts, Jr., Esquire Winston & Strawn Law Firm 1400 L Street, N.W.
Washington, D.C.
20005-3502 Resident Inspector /Sumer NPS 3
c/o U.S. Nuclear Regulatory Comission Route 1, Box 64
{
Jenkinsv111e, South Carolina 29065 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta St., NW., Ste. 2900
)
Atlanta, Georgia 30323 i
j Chairman, Fairfield County Council Drawer 60 Winnsboro, South Carolina 29180 Mr. Virgil R. Autry Director of Radioactive Waste Management Bureau of Solid & Hazardous Waste Management Department of Health & Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Mr. Robert M. Fowlkes, Manager Operations South Carolina Electric & Gas Company Virgil C.. Summer Nuclear Station, Mail Code 303 Post Office Box 88 l
Jenkinsville, South Carolina 29065 Ms. April R. Rice, Manager Nuclear Licensing & Operating Experience South Carolina Electric & Gas Company i
Virgil C. Summer Nuclear Station, Mail Code 830 Post Office Box 88 Jenkinsville, South Carolina 29065
!