bJ fa 4

i

,f j'

4 gg3 c 1 s n;

~ ' ~ -

ft-39 Nt! TECH, Inc.

A"TN: Dr. John V. Massey NUHOMS Project Manager 145 Partinvale Lane San Jose, California 95119 Gentlemen:

In response to your letter of September 19, 1985 and our telephone discussion of it, it appears that the proposed actions to resolve NRC coements and revise your topical report are generally sound.

Our remaining concerns center on the success of your implementation of the NUTECH Action Plan briefly outlined in your letter.

The only comments we can offer in this area are as follows. With respect to the ACI code, good documentation and a solid justifica-tion, perhaps buttressed, as feasible, by actions to be followed under the proposed in-senice inspection progra'n are recommended.

With respect to the criticality and shielding analyses, it is clear that a significant effort is ner:ded, particularly to complete the analyses and resubmit a revised topical report by the dated proposed in your letter. Hovember 1,1985. Finally, with respect to the in-seWice inspection program proposed, it is suggested that each new concrete module and canister be examined after its first full year of seWice.

Sincerely, 04.a u C Ly deknF. 20 borts

,a Leland C. Rouse, Chief FD W h

Advanced Fuel and Spent DISTRIBUTION:

Fuel Licensing Branch FC Central Files Division of Fuel Cycle NMSS r/f and Vaterial Safety FCAF r/f fM-39 File FBrown PDR JRoberts FSturz 8510070559 851001 JSchneid PDR PROJ M-39 POR J

LCRous h c

R C....

. ~........... - ~

.... ~... ~......

.-. ~ ~ ~ ~.. ~

~... ~ ~ ~. ~.

~~~~----

cu:N = > JR9h.ts.;,0.c. L C p.y E e........

..-~.-~~~.

~~~.-~~~

~ ~ ~ ~ ~ ~ ~ ~ -

~ ~ ~ - ~ ~ " - ".

- -""~"-"

10/....I... 85 10 ) /8

............'. ~....

om>

~.~..~.~~~

~~~~~~~~

~~~~ -"""-

NAC FORM 3tS itO'80l NRCM O240 OFFICIAL RECORD COPY