ML20133C906

From kanterella
Jump to navigation Jump to search
Deficiency Rept SD-83 Re Improper Installation of Upper Reactor Internal in-core Thermocouple Compression Fittings, Mfg by Hoke,Inc & Supplied by Westinghouse.Initially Reported on 850522.Next Rept Expected by 850910
ML20133C906
Person / Time
Site: Millstone 
Issue date: 06/21/1985
From: Opeka J
NORTHEAST NUCLEAR ENERGY CO., NORTHEAST UTILITIES
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
F0787A, F787A, SD-83, NUDOCS 8507220036
Download: ML20133C906 (2)


Text

-=

NORTDMAST UTILITIES o.n.,.i on.c... s.io n sir i. e.,nn. conn.ciicui

'7v7.DN 5Nco~-~~

P.O. BOX 270

.ovoaaera*wacw ~

HARTFORD. CONNECTICUT 06141-0270 k

L J (( Z $Y;"g*

(203) 665-5000 June 21,1985 Docket No. 50-423 F0737A Dr. Thomas E. Murley Regional Administrator U. S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406

Dear Dr. Murley:

Millstone Nuclear Power Station, Unit No. 3 Reporting of Potential Significant Deficiencies in Accordance with 10CFR50.55(e):

Incore Thermocouple Compression Fittings (SD-83)

In a May 22, 1985 telephone conversation between your Mr. D.1.ipinski and our Mr. A. 3. Silvia, Northeast Nuclear Energy Company (NNECO) reported a potential significant deficiency in the construction of Millstone Unit No. 3 as required by 10 CFR 50.55(e). The potential significant deficiency involves the improper installation of upper reactor internal incore thermocouple compression fittings.

The subject fittings were Hoke, Inc. "Gyrolock" type compression fittings and were supplied by Westinghouse and iristalled in accordance with Westinghouse procedures.

During primary system cold hydrostatic testing, one compression fitting became dislodged. A 100 percent inspection of the remaining subject compression fittings was conducted after completion of the primary cold hydrostatic test.

Approximately 25 percent of these fittings displayed ferrule axial movement.

Our NSSS supplier, Westinghouse Electric Corporation and our engineering staff are in the process of evaluating the conditions concerning the subject compression fittings. Until additional information is obtained, the corrective action and final report cannot be providej,'. We will provide an update on this matter by September 10,1985.

Very truly yours, NORTHEAST NUCLEAR ENERGY COMPANY

.f<0WN

3. F. Opekd G

Senior Vice President SBF2;ggggggggga s

)

I () 4q

A M

w

-WA.

4 me+-

4 4

4x44-b.--

4 A-1 4-p-

4*

M-4 4-44&

.e..j.,

2-a cc: - Mr. 3. M. Taylor, Director.

j

. Division of Inspection and Enforcement

. U.S. Nuclear Regulatory Commission Washington, D.C. 20555 k

I F

4 c

4 f

f 4

1 k

4 k

4

'I T

T 4

J I

.I I

i

'a i

. )

f r

~

y

,,, _ __