ML20133C744

From kanterella
Jump to navigation Jump to search
Advises That Supplemental Info Will Be Submitted to NRC Re GL 96-05, Periodic Verification of Design-Basis Capability of Safety-Related Motor-Operated Valves, by 970317
ML20133C744
Person / Time
Site: Callaway 
Issue date: 12/12/1996
From: Schnell D
UNION ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
GL-96-05, GL-96-5, ULNRC-3507, NUDOCS 9701080075
Download: ML20133C744 (4)


Text

.-

~ - -, - -.

i 1901 Chouteau Amnue I

Post Othee Box 'I49

.s' St. Louis. Muscuri S3166

\\

314-554 2650 l

t December 12, 1996 Union o

's ~ "c" Etscrnic

?" c':" *'"'

E l

U.

S. Nuclear Regulatory Commission ATTN:

Document Control Desk Mail Station P1-137 Washington, D. C.

20555-0001 Gentlemen:

ULNRC-3507 CALLAWAY PLANT DOCKET NUMBER 50-483 PERIODIC VERIFICATION OF DESIGN-BASIS CAPABILITY OF SAFETY-RELATED MOTOR-OPERATED VALVES l

References:

1) NRC Generic Letter 96-05 dated September 18, 1996
2) ULNRC-3487 dated November 6, 1996
3) NRC Letter from K. M. Thomas to D.

F.

Schnell dated November 29, 1996 Generic Letter 96-05 requested licensees to establish a program, or ensure the effectiveness of the current program, to verify on a periodic basis that i

safety-related motor-operated valves (MOVs) are capable of performing their safety functions within the current licensing bases of the facility.

GL 96-05 also required submittal of a written summary description of the MOV periodic verification program.

Our response (Reference 2) indicated that all actions requested by GL 96-05 were closed.

This conclusion was based on staff approval of the Callaway Plant GL 89-10 program, which includes a commitment to maintain a periodic verification program, and our involvement in industry activities.

However, because of subsequent activities within the industry and NRC to address long-term MOV performance, the staff, in Reference 3, requested additional information f

concerning any actions we will be taking in response to l

GL 96-05.

9701000075 961212 I

PDR ADOCK 05000483 PDR l

p 000021

4 h

STATE OF MISSOURI

)

)

SS CITY.OF ST. LOUIS

)

i Donald F.

Schnell, of lawful age, being first duly sworn upon oath says that he is Senior Vice President-Nuclear and an officer u Union Electric Company; that he has read the foregoing ( m anent and knows the content thereof; that he has executed th2 same for and on behalf of said company with full power and authority to do so; and that the facts therein stated are true and correct to the best of his knowledge, information and belief.

By

' Donald F.

Schnell Senior Vice President Nuclear l

BS sworn to bef me this [A'#/M day 1

i l

V O VQ BARBARA J. PFAFE NOTARY PUBUC-STATE Of MISSOURI MY QQMMISSION EXPIRES APRIL 22, 1997 1

ST LOUIS COUNTY l

i i

l l

l l

l

l' i

As agreed in a December 2, 1996 telecon with the NRC, Union Electric will supplement the November 6, 1996 letter with more specific information regarding changes or the need for changes in our MOV periodic verification program brought about by industry and NRC activities over the last few years including but not limited to:

1.

completion of the MOV performance prediction program by the Electric Power Research Institute and NRC issuance of a safety evaluation on the j

EPRI program; 2.

preparation of a code case by the American Society of Mechanical Engineers on an MOV periodic verification program that could be used as an alternative to stroke-time testing; and 3.

tests sponsored by the NRC on the aging of valve material samples.

We will submit this supplemental information by the GL 96-05 180-day response date of March 17, 1997.

If the foregoing actions are not completely responsive to your request, or if you have any further questions concerning this letter, please contact us.

Very truly yours, r

Donald F.

Schnell WEK/

.~

,e' cc:

M. H. Fletcher Professional Nuclear Consulting, Inc.

l 19041 Raines Drive Derwood, MD 20855-2432 L. Joe Callan Regional Administrator

'U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive Suite 400 Arlington, TX 76011-8064 Senior Resident Inspector l

Callaway Resident Office U.S. Nuclear Regulatory Commission l

8201 NRC Road 1

Steedman, MO 65077 Kristine M. Thomas (2)

Office of Nuclear Reactor Regulation l

U.S. Nuclear Regulatory Commission i

1 White Flint, North, Mail Stop 13E16 11555 Rockville Pike l

Rockville, MD 20852-2738 l

l Manager, Electric Department Missouri Public Service Commission l

P.O. Box 360 l

Jefferson City, MO 65102 l

l l

r

{

l

_-