_ _ _ _ _ _

e SEP 2 41985 Docket No.99990001 General License Mobile Pipeline ATTN: Mr. Bob Schaffer Station Operator Hood Road Paoli, Pennsylvania 19301 Gentlemen:

Subject:

Inspection Report No. 99990001/85-10 This refers to the special safety inspection conducted by Mrs. Marlene J. Taylor of this office on June 14, 1985, of activities authorized by the NRC General License contained in 10 CFR 31.5 and to the discussions of our findings held by Mrs. Taylor with yourself at the conclusion of the inspection.

The inspection was an examination of activities conducted under your license as they relate to radiation safety and to compliance with the Commission's rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, measurements made by the inspector, and observations by the inspector.

Based on the results of this inspection, it appears that one of your activities was not conducted in full compliance with NRC requirements, as set forth in the Notice of Violation, enclosed herewith as Appendix A.

This violation has been categorized by severity level in accordance with the revised NRC Enforcement Policy (10 CFR 2, Appendix C) published in the Federal Register Notice (49 FR 8583) dated March 8, 1984. You are required to respond to this letter and in preparing your response, you should follow the instructions in Appendix A.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and your reply will be placed in the Public Document Room.

The responses directed by this letter and the accompanying Notice are not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

$g100f% !

P 99990001

\\

I OFFICIAL RECORD COPY DL MOBILE - 0001.0.0 09/17/85 RETURN ORIGINAL TO Q

REGION I

SEP 2 41985 e

Mobile Pipeline 2

Your cooperation with us in this matter is appreciated.

Sincerely, Original Signed By John D. Kinneman John D. Kinneman, Chief Nuclear Materials Safety Section A, Division of Radiation Safety and Safeguards

Enclosure:

Appendix A, Notice of Violation cc w/ encl:

Public Document Room (POR)

Nuclear Safety Information Center (NSIC)

Commonwealth of Pennsylvania bec w/ encl:

Region I Docket Room (w/ concurrences)

Senior Operations Of ficer (w/o encl)

]l(ylT W

RI:0RSS

II
0RSS Taylor /djh Kinneman 9fb85 9////85 0FFICIAL RECORD COPY DL MOBILE - 0002.0.0 09/17/85 i