1 O PS G Company Pubi;c Service Entnc ana Gas 80 Park Pla/a, Newar k, NJ 07101/ 201430 8217 MAILING ADDRESS / P.O. Box 570, Nev. ark, NJ 07101 Robert L. Mitti General Manager Nuclear Assurance and Regulation October 1, 1985 Director of Nuclear Reactor Regulation U.S.

Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, MD 20814 Attention:

Mr. Walter Butler, Chief Licensing Branch 2 Division of Licensing Gentlemen:

HOPE CREEK GENERATING STATION DOCKET NO. 50-354 We have reviewed the draft Hope Creek Environmental Protec-tion Plan (EPP) submitted by your letter of July 26, 1985 PSE&G's comments are as follows, (Note:

underlined words have been added and [ bracketed] words deleted from the text):

4.2.2 Terrestrial Ecology Monitoring The applicant will implement the Salt Drift Monitoring Program to assess the impacts of cooling tower salt drift on the environment in the ECGS vicinity provided to NRC by letter dated March (18P 28, 1984 from Robert L.

Mittl, Public Service Electric and Gas Company, to A. Schwencer, U.S.

Nuclear Regulatory Commission.

The monitoring program shall commence one year prior to the onset of commercial operation of the HCGS and include [one year of] low-power testing and [two years of] operational data up.to three years from receipt of license or until such earlier time that the licensee can demonstrate that the objectives of the study have been fulfilled.

Annual moni-toring reports shall be submitted to the NRC for review.

5.1 Review [and Audit]

The licensee shall provide for review [and audit] of com-pliance with the EPP.

The [ audits] review shall be con-ducted independently of the individual or groups responsible C.00I S5100

  1. !O The Energy People es1= @48 o wo354 eor PDR v,4mv3 7a3 A

r-

.gr Director of Nuclear

' Reactor Regulation 2

10/1/85 for performing.the specific activity.

A description of the organizati~on structure utilized to achieve the independent review. [and audit] function and results of the [ audit]

review activities shall be maintained and made available for inspection.

Should you-have any questions concerning these comments, please contact us.

Very truly yours, ll sfhI C

D.

H. Wagner USNRC Licensing Project Manager FH1 1/2 C

-. ~

.,,,..m,

,