ML20133A468

From kanterella
Jump to navigation Jump to search
Discusses Plant Performance Review of Dresden Nuclear Station & Advises of Planned Insp Effort Resulting from Review
ML20133A468
Person / Time
Site: Dresden  
Issue date: 12/24/1996
From: Hiland P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Jamila Perry
COMMONWEALTH EDISON CO.
References
NUDOCS 9612310118
Download: ML20133A468 (3)


Text

l r

o l

Dm+or 24, 1996 Mr. J. S. Perry Site Vice President l

Dresden Station Commonwealth Edison Company 6500 North Dresden Road Morris, IL 60450

SUBJECT:

PLANT PERFORMANCE REVIEW (PPR) - DRESDEN NUCLEAR STATION

Dear Mr. Perry:

On September 24, 1996, NRC Region III management and staff completed the Plant Performance Review (PPR) of the Dresden Nuclear Station. The Region conducts these reviews for all operating nuclear power plants to develop an integrated understanding of safety performance. The results are used by regional management to facilitate planning and allocation of inspection resources.

The l

PPR for the Dresden Nuclear Station involved the participation of all Region l

III technical divisions as well as responsible NRR staff, in evaluating l,

inspection results and safety performance information for the period from March 1996 through September 1996.

The PPRs provide regional management with a current summary of licensee performance and serve as inputs to the NRC l

Systematic Assessment of Licensee Performance (SALP) and senior management meeting (SMM) reviews.

I This letter advises you of our planned inspection effort resulting from the Dresden Nuclear Station PPR review. The information is provided to enable appropriate consideration of the resource impact on your staff, and to permit I

scheduling conflicts and personnel availability issues to be resolved in l

advance of inspector arrival onsite. The enclosure details our inspection plan for approximately the next 6 months. The rationale or basis for each l

inspection outside the " Core" inspection program is provided so that you are aware of the reason for emphasis in these program areas.

Resident inspections, as well as periodic inspections by other assigned members of our site focus group, may occur at any time in support of the Core inspection program.

In addition to the PPR, the results of the recent Independent Safety Inspection Team will be evaluated to determine if modifications to the enclosed plan are needed. Changes will be discussed with your staff on a case by case bases.

Finally, as described in the Confirmatory Action Letter, dated I

November 21, 1996, monthly meetings will be held to review the results of your corrective action initiatives.

9612310118 961224 PDR ADOCK 05000010 0

PDR

Mr. Perry

  • 1 We are interested in feedback on this program, including the nead for any changes in the inspection plan, and we invite your questions or comments.

If changes are necessary, you will be informed.

If you have any questions or comments, please contact Mr. Pat Hiland at (630) 829-9603.

Sincerely,

/s/ Jay Hopkins for Patrick L: Hiland, Chief Reactor Projects Branch 1 Docket Nos.50-010, 50-237, 50-249 License Nos. DPR-2, DPR-19, DPR-25

Enclosure:

Inspection Plan cc w/ encl:

T. J. Maiman, Senior Vice President l

Nuclear Operations Division l

D. A. Sager, Vice President, Generation Support H. W. Keiser, Chief Nuclear l

Operating Officer l

T. Nauman, Station Manager Unit 1 M. Heffley, Station Manager Units 2 and 3 F. Spangenberg, Regulatory Assurance Manager

1. Johnson, Acting Nuclear Regulatory Services Manager Richard Hubbard Nathan Schloss, Economist Office of the Attorney General l

State Liaison Officer Chairman, Illinois Commerce Commission l

Document Control Desk-Licensing Distribution:

Docket File w/ encl Project Manager, NRR w/ encl PUBLIC IE-01 w/ encl DRP w/ encl l

OC/LFDCB w/ enc 1 RIII PRR w/ enc 1 l

SRI LaSalle, Dresden, CAA1 w/ encl (E-Mail)

)

Quad Cities w/ encl A. B. Beach, w/ encl j

RACI (E-Mail)

B. L. Burgess, w/ encl I

W. L. Axelson, w/ encl g g...

...,,., smi.. - i. i m.i. 4. s..

. c - c.,,.iin..

.ti.cnf...i -r - c,,.iin.si.cmi. i n-0FFICE RIII b

RIIJ b

RIII,c,

.n b RIII/DRP

/5

..n NAME KozaI/N Xh/ Lea $b Gade7/k Hiland/)dE v

DATE 12/J4/96 12/zo/96 12/@/96 12/pl/96 0FFICIAL RECORD COPY 310003

Dresden Nuclear Station

~

INSPECTION PLAN INSPECTION TITLE /

NUMBER OF PLANNED TYPE OF INSPECTION-PROGRAM AREA INSPECTORS INSPECTION COMMENTS DATES Security /

Core Inspection and IP 81700 Plant Support 1

1/13-17/97 Followup on Previously Identified Weaknesses Inservice Testing U-2 Refuel Core Inspection IP 73753 Inspection / Engineering 1

Outage SRO/RO Licensed Operator 3

3/24-28/97 Initial Examinations Initial Initial Examination Radiation Protection /

Core Inspection and IP 83750 Plant Support 1

3/31-4/4/97 Followup on Previously Identified Weaknesses IP 62706 Maintenance Rule 4

5/5-9/97 Verify Implementation of Inspection Maintenance Rule IP 93801 System Operational 3

July 1997 Regional Initiative Performance Inspection Enclosure IP - Inspection Procedure CI - Core Inspection - Minimum NRC Program (mandatory all plants)