Decenber 20, 1996 Mr. John H. Mueller Site Vice President Zion Station Commonwealth Edison Company 101 Shiloh Boulevard Zion, IL 60099

SUBJECT:

PLANT PERFORMANCE REVIEW (PPR) - ZION

Dear Mr. Mueller:

On November 7,1996, NRC Region ill management and staff completed the Semiannual Plant Performance Review (PPR) of the Zion Nuclear Power Plant. The Region conducts these reviews for all operating nuclear power plants to develop an integrated understanding of safety performance. The results are used by regional management to facilitate planning and allocation of inspection resources. The PPR for the Zion Nuclear Power Plant involved the participation of all Region l11 technical divisions as well as responsible NRR staff,in evaluating inspection results and safety performance information for the period from March through October 1996. PPRs provide regional management with 1 a current summary of licensee performance and serve as inputs to the NRC Systematic Assessment of Licensee Performance (SALP) and senior management meeting (SMM) reviews.

This letter advises you of our planned inspection effort resulting from the Zion Nuclear Power Plant PPR review. The information is provided to enable appropriate consideration of the resource impact on your staff, and to permit scheduling conflicts and personnel availability issues to be resolved in advance of inspector arrival onsite. The enclosure details our inspection plan for approximately the next 6 rnonths. The rationale or basis for each inspection outside the " Core" inspection program is provided so that you are aware of the reason for emphasis in these program areas. Resident inspections, as well as periodic inspections by other assigned members of our inspection staff, may occur at any time in support of the Core inspection program.

I i

I 9612310017 961220 PDR ADOCK 05000295 0 PDR

__ _. . _ .~ _ __. _ _. .__ __ ._

.. l J. Mueller .

We are interested in feedback on this program, including the need for any changes in the i ,

inspection plan, and we invite your questions or comments, if changes are necessary, you I will be informed. If you have any questions or comments, please contact me at

. (630) 829-9628.

i

Sincerely,

/s/ Marc L. Dapas Marc L. Dapas, Chief

, Reactor Projects Branch 2 Docket Nos.: 50-295; 50-304 1

1 License Nos.: DPR-39; DPR-48  !

Enclosure:

Inspection Plan cc w/ encl: T. J. Maiman, Senior Vice President Nuclear Operations Division i D. A. Sager, Vice President, i Generation Support i

H. W. Keiser, Chief Nuclear i Operating Officer G. K. Schwartz, Station Manager W. Stone, Regulatory Assurance

Supervisor
l. Johnson, Acting Nuclear
j. Regulatory Services Manager Richard Hubbard i Nathan Schloss, Economist Office of the Attorney General j Mayor, City of Zion

. State Liaison Officer, Wisconsin State Liaison Officer Chairman, Illinois Commerce Commission

! Document Control Desk-Licensing Distribution:

Docket File w/enci Project Manager, NRR w/enci PUBLIC IE-01 w/ encl DRP w/enci  ;

OC/LFDCB w/enci Rill PRR w/enci l 3

SRI Byron, Braidwood, CAA1 w/enci (E-mail) j Zion w/enct W. L. Axelson, w/enct A. B. Beach, w/enci RAC1 (E-Mail)

! B. L. Burgess, w/ encl g ,r . . .. . ,, ., in i . .. . . .. ... . i . i n. . c . c.,, .4 6... .i t..nf... i -c . c.,, .i t .i t..nf... i u.

OFFICE RIII S RIII. b RIII h RIII/DRP 8

! NAME iing/Leac b Kroop/6i$b KoI h rdnerN Dapas 8 M DATE 12/6/96 12/V/96 12/M/96 12/26/96 3

0FFICIAL RECORD COPY

ZION .

INSPECTION PLAN INSPECTION TITLE / NUMBER OF PLANNED TYPE OF PROGRAM AREA INSPECTORS INSPECTION INSPECTION -

DATES COMMENTS IP 83750 Occupational Radiation 1 1/13-17/97 Core Inspection -

Exposure IP 81700 Physical Security Program 2/3-7/97 Core Inspection 1

IP 82701 Operational Status of 2 3/17-21/97 Core Inspection Emergency Preparedness Program IP 73753 Inservice Inspection 1 3/24-28/97 Core Inspection IP 83750 Occupational Radiation 1 4/7-11/97 Core Inspection Exposure IP 93802 Operational Safety Team To Be Late Regional Inspection Determined April 1997 Initiative Inspection-Personnel Performance IP 81700 Physical Security Program 1 5/12-16/97 Core Inspection IP 92904 Plant Support (Radiation 1 6/9-13/97 Regional Protection) Followup Initiative-Routine Followup of Issues Enclosure IP - Inspection Procedure '

TI - Temporary Instruction Core Inspection - Minimum NRC Inspection Program (mandatory all plants)

. _ . _-_, . - . - - _ - . - - _.