Responds to NRC Re Violations Noted in Insp Rept 50-298/96-19 on 960728-0907.Corrective Actions:Issuance of non-conforming Parts for Essential Applications & Procedure 7.3.16 Changed
ML20133A073
Person / Time
Site: Cooper 
Issue date: 11/06/1996
From: Peckham M
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20133A066 List:
References
NLS960206, NUDOCS 9612300059
Download: ML20133A073 (6)


Text

.

i COOPER NUCLEAR STATION P.O. BOX 98. BROWNVILLE. NEBRASKA 68321 Nebraska Public Power District

=raL*=='"

=a NLS960206 November 6, 1996 e

l Director, Office of Enforcement id)/ I l-I U. S. Nuclear Regulatory Commission j

Attention: Document Control Desk j

Washington, D.C.

20555 J

i Gentlemen l

Subject:

Reply to a Notice of Violation; NRC Inspection Report No. 50-298/96-19; Cooper Nuclear Station, NRC Docket 50-298, DPR-46

Reference:

Letter from Mr. J.

E. Dyer (USNRC) to Mr. G. R. Horn (NPPD), dated October 7, 1996, NRC Inspection Report 50-298/96-19 and Notice of Violation.

This letter, including Attachment 1, constitutes Nebraska Public Power District's (the District) reply to the referenced Notice of Violation in accordance with 10 CFR 2.201.

Inspection Report 50-298/96-19 documented the results of an NRC routine inspection conducted from July 28 through September 7, 1996, of aspects of Cooper Nuclear Station (CNS) operations, engineering, modifications and testing, maintenance, plant support, and Updated Safety Analysis Report.

The District admits the violations and has completed all corrective actions that are necessary to return Cooper Nuclear Station (CNS) to full compliance with regard to 10CFR50 Appendix B, Criterion V.

Should you have any questions concerning this matter, please contact my office.

Sincer y,

M.

F.

Peckham Plant Manager 9612300059 961224 PDR ADOCK 05000298 Attachment 3

PDR cc:

Regional Administrator USNRC - Region IV Senior Project Manager USNRC - NRR Project Directorate IV-1 Senior Resident Inspector USNRC - Cooper Nuclear Station cf 7-o Z o i NPG Distribution

4 Attochment 1 to NLS960206 Page 1 of 4 REPLY TO OCTOBER 7, 1996, NOTICE OF VIOLATION COOPER NUCLEAR STATION NRC DOCKET NO. 50-298, LICENSE DPR-46 During NRC inspection activities conducted from July 28 through September 7,

1996, two violations of NRC requirements were identified.

The particular violations and the District's reply are set forth below:

"10 CFR Part 50, Appendix B, Criterion V,

states, in part, that activi ties

)

affecting quality shall be prescribed by documented instructions or procedures, of a type appropriate to the circumstances, and shall be accomplished in l

accordance with these instructions or procedures.

Procedure 0.5,

" Problem Identification and Resolution," Revision 8, Step 4.4.3, states, in part, that an operability assessment is required for conditions which could affect the

)

operability or design of licensing basis structures, systems, and components.

Procedure 7.3.16, ' Low Voltage Relay Removal and Installation," Revision 8, Step 6.1, requires, in part, that interaction with other systems or equipnent be fully researched prior to installing jumpers, lif ting leads, or removing a relay.

' Contrary to the above, on September 6, 1996, Maintenance Work Order 96-1398 installed jumpers and replaced a reiny affecting the operability of the essential second level undervoltage protection circuit for Vital Bus F relay dc power. An operability assessm:nt was not perfonned for the use of an unqualified relay, and the interaction of the installed jumpers with other systems was not researched prior to installing the jumpers.

These conditions affected the operability of the essential second level undervoltage protection circuit of Vital Bus F relay

)

de power."

4 1

Admission or Denial to Violation i

The District admits the violation.

Reasons for Violation This violation consists of two parts. The first part is the installation of a non-qualified relay in a safety-related application pursuant to a maintenance 4

activity.

An operability assessment was not performed to support its functionality relative to affected safety functions. The circumstances of this e

part are described in Section 04.1.b of the referenced Inspection Report. The second part concerns the failure to assess system interactions on Operability when temporary jumpers were installed during this same maintenance activity. The circumstances of this part are described in Section M1.2.b of the Inspection Report.

Part 1-This part of the Violation occurred because Plant Engineering personnel did not adequately rev ew the full functionality of the non-conforming relay and its effects on auxiliary circuit operability prior to initiating the relay replacement activity.

Station Procedure 1.8,

" Warehouse Issue, Return and Shipping", Revision 18, allows the issuance of parts which have non-conforming conditions for installation in Essential applications, provided there is appropriate Engineering and Management concurrence.

Although not an explicit i

i

_..__,_._m.-

4

j.
  • to WLS960206 3,

i Page 2 of 4 i

procedural requirement, this type of issuance has historically been performed 1

when the end use application has been verified to be out-of-service.

That this l

verification was not properly performed is due in large part to the lack of

}

procedural prescriptiveness in what the proper review scope should be, and

}

required documentation as to its accomplishment.

Because the relay auxiliary functions were not recognized, the Shift Supervisor presumed that the existing j

Technical Specification (TS) Limiting Condition for Operation (LCO) 3.9.B.1.a for i

Emergency Transformer inoperability was properly encompassing, and he did not i

request a formal Operability Assessment (OA).

An OA was later performed which corroborated the Shift Supervisor's judgment that equipment Operability was not a

]

adversely affected by the relay non-conformance.

i f.

Part 2-The reason for this part of the Violation is that Management's expectations for proper assessment of this temporary jumper installation was not i

- adequately proceduralized. The wording in Limitation 6.1 of Procedure 7.3.16 j

could be understood to mandate a circuit review to ensure maintenance could be i

performed without causing an unplanned actuation or loss of function, rather than I

as a mechanism to resolve Operability questions.

As noted in the Inspection i

Report, the jumpers were installed for about three hours.

4 i

Corrective Stens Taken and the Results Achieved l

Part 1-The issuance of non-conforming parts for Essential applications is an infrequently performed activity.

However, interim Management action has been taken to better control this process by ensuring that a' review of the part's full i

contribution to system or component functionality is documented prior to issuance j

from'the Warehouse.

j 1

t Part 2-Procedure 7.3.16 has been changed to require a validation that the i

pending maintenance activity will not influence Operable equipment, otherwise the activity must be evaluated to justify its acceptability. This protocol has also been enhanced by requiring an independent second check of the conclusions j

reached.

Corrective Stens That Will Be Taken to Avoid Purther Violations I

i Procedure 1.8 will be revised to require explicit documentation of the part's

]

functionality review prior to issuance.

j Date When Full Comoliance Will Be Achieved l

Based on the effectiveness of the corrective actions taken to date, the District is in full compliance with the requirements of 10 CFR 50 Appendix B, Criterion i

V with respect to this violation.

4 i

"10 ' CFR Part 50, Appendix Be Criterion V,

states, in parta tha t activities affecting quality shall be prescribed by documented instructions or procedures, 4

of a type appropriate to the circumstances, and shall be accomplished in f

accordance with these ins tructions or procedures.

Procedup 2.0.1,

' Plant f

Operations Policy," Revision 27, Step 8.4.2 states that approved procedures 4

require step-by-step adherence by all personnel.

i e

4

__~ - - _, _

-~

~. -

~ - - -

. ~.

)

to NLS960206 Page 3 of 4

' Surveillance Procedure 6.HPCI.103,

'HPCI IST and Quarterly Test Mode Surveillance Operation " Revision 2, Step 9.2, directs removal of the lanyard o

potentioneter from the atop valve.

i

" Contrary to the above:

"On August 27, 1996, following performance of Surveillance Procedure 6.HPCI.103, the licensee declared the high pressure core [ sic] injection system operable without removing the lanyard potentiometer from the stop valve.

The lanyard potentiometer was installed for 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> without an evaluation of the affect on operability.

l

'On August 29, 1996, Procedure 7.2.53. 7, " Operation of Engine Analysis," Revision 0.2, was not appropriate to the circumstances in that no inetructions were i

established to control installation of test equipment. The safety evaluation for l

Procedure 7.2.S3.7 seaeed that teat equipaent should only be installed while the diesel generator is in an allowed outage time or not required to be operable.

Diesel Generator 2 was returned to an operable status with test equipment

{

installed."

Admission or Denial to Violation l

The District admits the violation.

Reasons for Violation The District has reviewed the circumstances described in Section M1.3 of Inspection Report 96-019 with regard to the first part of this Violation. The Shift Supervisor made a judgment that HPCI could be declared operable without removing the lanyard potentiometer due to the existing procedural controls that I

inappropriately allowed him to exit the HPCI Allowed Outage Time (AOT) without completing Step 9.2.

With regard to the second part of this violation, the 10CFR50.59 applicability review that was performed for Procedure 7.2.53.7, Revision 0,

states the following:

I This procedure gathers data to be used in the assessment of EDG [ Emergency Diesel Generator) condition for the purposes of predictive maintenance.

l While the data gathering is intrusive and has the potential for damage or negative performance impact, the EDG equipment is either performing per the surveillance, in an AOT [ Allowed Outage Time), or not required by plant condition during the performance of this procedure.

l While miscommunication was a factor in this event, Maintenance and Operations personnel qualitatively did not consider the physical attachment of the motion encoder assembly to be a part of the " data gathering activity" described above in that it was neither intrusive nor having the potential for EDG damage or negative performance impact. Nevertheless, it was inappropriate to have declared the EDG Operable without a prior Operability Assessment that discussed any changes to its current seismic qualification.

l l

- _ ~ -

. _~. _ - - -. _ - _ -. - -.-.. _. _ -. -..-.

g e

to NLS960206 Page 4 of 4 Corrective Stens Taken and the Results Achfeved An evaluation was performed for both of the above configurations which concluded that neither situation adversely affected component or system - operability.

Instruction has been provided to operations personnel to heighten their sensitivity to test equipment installed on Technical Specification controlled systems and components.

Procedure 7.2.53.7 has been changed to ensure the Control Room is aware of when the EDG testing equipment has been installed.

Corrective Stens That Will Be Taken to Avoid Further Violations The CNS surveillance testing procedures are being reviewed in order to ensure the installation and removal of test equipment is performed consistently with Operability requirements.

l Date When Full Comoliance Will Be Achieved Based on the Engineering dispositions of the specific Operability concerns raised by these two issues and the corrective actions taken to date, the District is in full compliance with the requirements of 10 CFR 50 Appendix B Criterion V with respect to this violation.

l 1

l l

i l

J

(

1 f

l r

I

,_.m

[

LIST OF NRC COMMITMENTS ATTACHMENT 3 Correspondence No:NLS960206 The following table identifies those actions committed to by the District in this document.

Any other actions discussed in the submittal represent intended or planned actions by the District.

They are described to the NRC for the NRC's information and are not regulatory commitments.

Please notify the Licensing Manager at Cooper Nuclear Station of any questions regarding this document or any associated regulatory commitments.

j COMMITMENT COMMITTED DATE OR OUTAGE Procedure 1.8 will be revised to require explicit None documentation of the part's functionality review prior to issuance.

The CNS surveillance testing procedures are being None reviewed in order to ensure the installation and removal of test equipment is performed consistently with operability requirements.

i PROCEDURE NUMBER 0.42 REVISION NUMBER 0 PAGE 12 OF 16