ML20132G456

From kanterella
Jump to navigation Jump to search
Forwards Safety Evaluation Re Pcrv Prestressing Tendon Wire Corrosion Problems.Submittals Dtd 850520 & 0614 Acceptably Resolve Concerns.Lasl Evaluation Rept Encl
Date released: 05/25/2020 Download: ML20132G456


Evaluation of CRD Mechanism & Reserve Shutdown Sys Failures & Pcrv Tendon Degradation Issues Prior to Fort St Vrain Restart.
ML20132G502
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 03/12/1985
From: Bennett D, Fly G, Fugelso L
LOS ALAMOS NATIONAL LABORATORY
To: MILLER J R
Office of Nuclear Reactor Regulation
References
CON-FIN-A-7290
Download: ML20132G502 (30)
Safety Evaluation Re Pcrv Tendon Corrosion Investigation & Proposed Remedy.Tendon Surveillance Proposal Acceptable
ML20132G476
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 07/08/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV), Office of Nuclear Reactor Regulation
To:
References
Download: ML20132G476 (3)
Forwards Safety Evaluation Re Pcrv Prestressing Tendon Wire Corrosion Problems.Submittals Dtd 850520 & 0614 Acceptably Resolve Concerns.Lasl Evaluation Rept Encl
ML20132G450
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 07/08/1985
From: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: LEE O R
PUBLIC SERVICE CO. OF COLORADO
References
Download: ML20132G450 (3)