ML20132F335

From kanterella
Jump to navigation Jump to search
Forwards Modified Pages to TS Change Request 170 Re 15.3.10, Control Rod & Power Distribution Limits, & 15.4.1, Operational Safety Review
ML20132F335
Person / Time
Site: Point Beach  
Issue date: 12/19/1996
From: Krieser G
WISCONSIN ELECTRIC POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20132F340 List:
References
VPNPD-96-110, NUDOCS 9612240200
Download: ML20132F335 (2)


Text

~.

Wisconsin Electnc POWER COMPANY 231 W Michigan. PO Box 2046. Mdwoukee.WI 53201-2046 (414)221 2345 VPNPD-96-110 10 CFR 50.4 10 CFR 50.90 December 19,1996 Document Control Desk US NUCLEAR REGULATORY COMMISSION Mail Station PI-137 Washington, DC 20555-0001 Ladics/ Gentlemen:

DOCKETS 50-266 AND 50-301 SUPPLEMENT TO TECHNICAL SPECIFICATIONS CHANGE REOUEST 170. MODIFICATION OF TS 15.3.10.

" CONTROL ROD AND POWER DISTRIBUTION LIMITS" AND TS 15 4.1 " OPERATIONAL SAFETY REVIEW" POINT BEACH NUCLEAR PLANT. UNITS I AND 2 in letters dated February 8,1996, and August 15,1996, Wisconsin Electric submitted Technical Specifications Change Request 170. This TSCR proposes amendments to the Point Beach Technical Specifications Section 15.3.10, " Control Rod and Power Distribution Limits," to improve the clarity of this section. A surveillance is being moved to Section 15.4.1 and i

a surveillance is being added to Section 15.4.1. Additionally, the guidance contained in the Westinghouse Owner's Group Improved Standard Technical Specifications, NUREG 1431, Revision 0, was used to aid in improving the specifications that u cre not clear. Modified pages for this change request were provided as an attachment to a letter dated December 2,1996.

in subsequent review of this Technical Specifications change request, it has been determined that the following corrections are needed:

1.

Change the required action times for Specifications 15.3.10.D.I.b and 15.3.10.D.2.b from 6 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. The original proposal for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> is not necessary. The 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> action time is consistent with the guidance contained in the Westinghouse Owner's Group Improved Standard Technical Specifications, NUREG 1431, Revision 0 and Revision 1.

2.

Add the following action statement to TS 15.3.10.E.3, Quadrant Power Tilt, for the condition if quadrant power tilt is not met," Reevaluate safety analyscs and confirm results remain valid for duration of operation under this condition. This action shall be completed prior to increasing thermal power above the limit imposed by Specification 15.3.10.E.3.a(1)." This requirement should be inserted as TS 15.3.10.E.3.a(3) and the subsequent specifications should be renumbered accordingly. This requirement to reevaluate safety analyses is consistent with the guidance contained in the Westinghouse Owner's Group Improved Standard Technical Specifications, NUREG 1431, Revision 0 and Revision 1.

3.

Correct a typographical error introduced in the edited Technical Specifications for this change request.

1 TS 15.3.10.G.3, change the word " rector" to " reactor."

l

-DDI

/>

9612240200 961219 PDR ADOCK 05000266 j

p PDR 2

A.wkwfan afHiwrmshiEnemTterva&w

4 Document Control Desk December 19,1996 Page 2 s

i It has been determined that these corrections to the proposed amendments do not alter the conclusion that these changes do

=

not involve a significant hazards consideration, authorize a significant change in the types or total amounts of any effluent release, or result in any significant increase in individual or cumulative occupational exposure. We, therefore, continue to conclude that the proposed amendments meet the requirements of 10 CFR S t.22(c)(9) and that an emironmental impact statement or negative declaration and environmental impact appraisal need not be prepared.

The modified pages are pro ided as an attachment to this letter to assist in the issuance of these amendments to the PBNP Technical Specifications. If you require additional information, please contact us.

1 Sincerely, 4

Gary M. 'rieser Manager-Industry and Regulatory Senices CAC Attachment cc:

NRC Resident Inspector NRC Regional Administrator j

PSCW Subscribed and sworn before me on this 1% day ofhahrr.1996.

[-)wJ 1

i tr%b i

6ma bIotry iblic, State of Wisconsin 1 commission expires bo 3

)