_

i

.1dY

'Af Duquesne Ucjit 2g-g1gs, (412.' 92M 960 Nuclear Construction Div'sion ocopy (412) T87-2629 Rob 6nson Plaza, Building 2. Suite 210 Pittsburgh, PA 15205 7-26-85 United States Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Mr. Harold R. Denton Of fice of Nuclear Reactor Regulation

SUBJECT:

Beaver Valley Power Station - Unit No. 2 Docket No. 50-412 P reservice Ins pe ct ion (PSI) and Inservice Ins pect ion (ISI)

Program Submittals

REFERENCES:

1) DLC Letter 2NRC-4-096, dated June 29, 1984
2) NRC Letter to DLC, dated June 8,1985
3) DLC Letter 2NRC-5-014, dated January 31, 1985
4) NRC Letter to DLC, dated May 20, 1985
5) DLC Letter 2NRC-5-032, dated February 21, 1985
6) DLC Letter 2NRC-5-055, dated March 27, 1985
7) NRC Letter to DLC, dated June 6,1985 Centlemen:

On December 12, 1984, Duquesne Light Company (DLC) met in Bethesda, MD, with the Materials and Testing Engineering Branch to discuss the PSI Pro-gram, which was submitted June 29, 1984 (Reference 1).

The NRC recently issued a meeting summary and comments on the progras (Reference 2).

On January 31, 1985, DLC submitted an alternative plan for the preservice exami-nation of ASME Class 2 piping welds (Reference 3).

On May 20, 1985, the NRC approved the methodology of the plan for ASME Class 2 welds (Reference 4).

On January 17, 1985, DLC met in Bethesda, MD, with the Mechanical Engineering Branch to discuss the criteria for pressure isolation valve leak testing (References 5 and 6).

The staff has recently issued the final draf t of the Safety Evalua-tion Report (Reference 7).

Open Issue 6 is on the submittal of the PSL and ISI Progemos.

Open Issues 2 and 3 are the preservice and inservice testing of pumps and valves.

FSAR ques t ions 210.40, 210.41, and 250.1 reques ted information on those programs earlier.

The purpose of this letter is to provide a submittat date for the completed PSI program document and for the preliminary ISL progran document, as weLL.

The completed PSL progems document is scheduled for December 31, 1985.

The preliminary ISI progran document is scheduled for June 30, 1986.

The scheduled dates are select ed to support the BVPS-2. fuel load date of April 30,1987.

\\

8509020200 850724, g$)i PDR ADOCK 05000412 G

PDR 1 0 i

L

L United Stcteo Nuclear R gulctory Conuniscion Mr. Harold R. Denton PSL and ISL Program Submittals Page 2 The PSL program document will incorporate resolutions to the staff comments, the alt e rnat ive plan fo r the examinatiot of ASM? Class 2 piping welds and the DLC proposed pump and valve leck testing progiam with specific requests for relief from Section XI of the ASME Code.

We trust that these submittal dates are ac cef.t ab le.

If you have any '

questions or conuments, please let us know by July 31,198').

DUQUESNE LIGiff COMPANY By J

arey,'

V tasident JJS/wjs cc:

Mr. B. K. Singh, Project Manager Mr. G. Walton, NRC Resident inspector 4

COMMONWEALTH OF PENNSYLVANIA )

l

)

SS:

COUNTY OF BEAVER

)

On this [/.) Idayof f/y-

((

before me, a Notary Public in and for said Cdmon alth and County,' pe rsonally appeared J.

J. Carey, who being duly sworn, deposed and said that (1) he is Vice Pres ide nt of Duquesne Light, (2) he is duly authorized t'o execate and ' file the foregoing Submittal on behalf of said Company, and (3) the statements set forth in the Submittal are true and correct to the best,of his knowledge.

Ah/

$52U

/

Notary Pubits pu e, tAl6eet. setART W

.j.ippiescent sees.esane County

's? Ceteiggeen Iwisil SEPI.14.1985 m sto. Peneogenus As* % N s

h

r._____--______

United States Nuclect Reguletory Commission Mr. Harold R. Denton PSI and ISI Program Submittals Page 3 JJS/wjs NR/NRC/ PSI /ISI bec:

J. J. Carey E. J. Woolever R. S. Christner C. E. Ewing T. D. Jones J. A. Hults R. E. Dougher E. F. Kurtz, Jr.

J. H. Latshaw R. E. Martin T. P. Noonan J. A. Rocco F. D. Schuster W. H. Sikorski R. J. Swiderski N. R. Tonet G. L. Beatty E. T. Eilmann R. W. Fedin S. D. Hall K. M. Holcomb

(

J. Lee, Esq.

F. C. Lin S. L. Fernick, Jr.

M. A. Zaki I

T. J. Zogiaann l

A. A. Dasenbrock l

J. R. Houghton D. E. Burke (CEI)

R. G. Schuerger (CEI)

5. M. MLLler (2) (DEC)

T. Gerusky -(PADER)

J. Silberg (SPPT)

C. Richardson (S&W)(5)

D. Chamberlain (S&W)

T. J. Lex (W)

B. Lorens (II)

~

DLC/ EPM NCD File