@' ATTACHMENT CON WITHHOLD FROM PUBLIC DISCLOSURE Consuniers Thomas C.Bordine Manager. Licensing SMO M Palisades Nuclear Plant: 27780 Blue Star Memorial Highway. Covert, MI 49043 December 16,1996 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT
SUMMARY
OF DESCRIPTION OF THE INSTALLED VEHICLE CONTROL MEASURES, REVISION 2 On August 1,1994, the Nuclear Regulatory Commission (NRC) iscued an amendment to 10 CFR Part 73 which modified the design basis threat for radiological sabotage.
The amendment required reactor licensees to install vehicle control measures, including vehicle barrier systems, to protect against the malevolent use of a land vehicle.
On February 28,1995, Consumers Power Company submitted a summary description of the proposed vehicle control measures as required by 10 CFR 73.55(c)(7), and the results of the vehicle bomb comparison as required by 10 CFR 73.55(c)(8).
Attached is Revision 2 of the summary description of the installed vehicle control mearures, which identifies a change to the vehicle barrier design made to address spe.:ific site conditions.
Tt e information contained in the enclosed documents has been classified as sa.9 guards information. Therefore, Consumers Power Company requests that the atta hment to this letter be withheld from public disclosure in accordance with 10CFR73,21(c).
WHEN SEPARATED FROM ATTACHMENT HANDLE THIS DOCUMENT AS DECONTROLLED 9612230401 961216
\\
8 PDR ADOCK 05000255
)
/
l l F
PDR y g,ygygycoyggyy
)
(
ATTACHMENT CONTAINS SAFEGUARDS INFORMATION 2
~
WITHHOLD FROM PUBLIC DISCLOSURE
SUMMARY
OF COMMITMENTS This letter contains no new commitments and no revisions to existing commitments.
l (ET Thomas C. Bordine i
Manager, Licensing CC Administrator, Region Ill, USNRC Project Manager, NRR, USNRC NRC Resident inspector - Palisades Attachment WHEN SEPARATED FROM ATTACHMENT HANDLE THIS DOCUMENT AS DECONTROLLED