ML20132E440

From kanterella
Jump to navigation Jump to search
Forwards Rev 9 to Safety-Related Piping Sys Support & Hanger Discrepancies, Summary Rept
ML20132E440
Person / Time
Site: Davis Besse 
Issue date: 09/20/1985
From: Williams J
TOLEDO EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20132E444 List:
References
1-576, NUDOCS 8510010086
Download: ML20132E440 (1)


Text

-

7 TOLEDO Docket No. 50-346 EDISON License No. NPF-3 JOE WILUAMS. JR.

Senor Vce Present-%ter Serial No. 1-576 lllljll@

September 20, 1985 FRIORITY ROUTING i

Ur_S3 1;*ff Mr. James G. Keppler L

' g -

Regional Administrator QjudC United States Nuclear Regulatory Commission gs p_

Region III M_Nk

,HW

~

799 Roosevelt Road Glen Ellyn, IL 60137

- f1L

Dear Mr. Keppler:

Enclosed is Revision 9 of the Safety-Related Piping System Support and Hanger Discrepancies Summary Report for the Davis-Besse Nuclear Power Station Unit No. 1.

Toledo Edison is updating this report weekly and submitting it to your office to keep your Staff notified of any new discrepancies, regardless of significance, which are identified on safety-related piping system hangers or supports.

Very truly yours, N

~~.St JW:DRW:lah enclosure cc: DB-1 NRC Resident Inspector D. Danielson, NRC Region III I. N. Jackiw, NRC Region III i-8510010006 850920 PDR ADOCK 05000346 SEP 231985 P

PDR c\\

O THE TOLEDO EDISON COMPANY EDISON PLAZA 30C MADISON AVENUE TOLEDO, OHIO 43652 0 \\l

- - - - -