T s

December 19, 1996 Mr. Louis G. Henry Manager of Environmental & Safety Services /BMRC Decommissioning Project Manager Buffalo Materials Research Center State University of New York Rotary Road Buffalo, New York 14214

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION 4

Dear Mr. Henry:

In order to complete our review of your application for a possession-only license (POL) and a Certified Fuel Handler Program (CFHP) for the Pulstar

)

Reactor at the State University of New York at Buffalo, submitted by your j

letter of July 23, 1996 and August 6, 1996, we need additional information.

Please provide answers to the questions in the enclosure to this letter within 60 days of the date of this letter and revise the Technical Specifications in your POL application, and the CFHP to incorporate the proposed responses.

If 3

you have any questions, please contact me at 301-415-1102.

This requirement affects nine or fewer respondents and, therefore, is not subject to Office of Management and Budget review under P.L.96-511.

Sincerely, i

I ORIGINAL SIGNED BY l

Theodore S. Michaels, Senior Project Manager Non-Power Reactors and Decommissioning Project Directorate Division of. Reactor Program lianagement Office of Nuclear Reactor Regulation Docket No. 50-57

Enclosure:

As stated cc w/ enclosure See next page DISTRIBUTION:

Docket File 50 T. Michaels PUBLIC Region I PDND r/f EHylton TMartin 0GC (015-B18)

SWeiss

[' '

I Qk h

BUFFALO.RAI c

s S

s 12/ /f/96 12/$/96 12/ /96 1

i

)

23cs o ?,"-

i 9612230200 961219 PDR ADOCK 05000057 P

PDR

ff#*"%,

4 UNITED STATES E

E NUCLEAR REGULATORY COMMISSION f

WASHINGTON, D.C. 205tW0001 December 19, 1996 i

Mr. Louis G. Henry Manager of Environmental & Safety Services /BMRC Decommissioning Project Manager a

Buffalo Materials Research Center State University of New York Rotary Road j

Buffalo, New York 14214

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION

Dear Mr. Henry:

In order to complete our review of your application for a possession-only license (POL) and a Certified Fuel Handler Program (CFHP) for the Pulstar

)

Reactor at the State University of New York at Buffalo, submitted by your i

letter of July 23, 1996 and August 6,1996, we need additional information, j

Please provide answers to the questions in the enclosure to this letter within 60 days of the date of this letter and revise the Technical Specifications in i

your POL application, and the CFHP to incorporate the proposed responses.

If

)

you have any questions, please contact me at 301-415-1102.

This requirement affects nine or fewer respondents and, therefore, is not subject to Office of Management and Budget review under P.L.96-511.

Sincerely, V

5.

Theodore S. Michaels, Senior Project Manager Non-Power Reactors and Decommissioning Project Directorate 4

Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-57

Enclosure:

As stated cc w/ enclosure See next page

State University of New York Docket No. 50-57 at Buffalo cc:

Dr. Paul J. Merges, Director Bureau of Radiation, DHSR NYS Department of Environmental Conservation 50 Wolf Road Albany, New York 12233-7255 Mr. John P. Spath NYS Energy Research and Development Authority Corporate Plaza West 286 Washington Avenue Extension Albany, New York 12203-6399

.%a

f REQUEST FOR ADDITIONAL INFORMATION Pertaining to the State University of New York's request for a Possession-Only License and a Certified fuel Handler Program POSSESSION-ONLY LICENSE General Ouestions 1.

Discuss additional measures that will be taken to ensure that K,,, will not be increased above the K existing in the initial fuel " stored" on the grid plate as a part of INis amendment request, and revise the Technical Specifications (TS) accordingly.

2.

Discuss how knowledgeable persons will be available at all times to respond to potential events at the Buffalo Materials Research Center.

These persons should have knowledge of important systems such as pool water level and radiation detection instrumentation and alarms.

3.

Discuss how measures will be taken to continuously provide radiation monitoring of the gaseous effluents from the building. This discussion could also address proposed allowed system outage times to permit maintenance or other expected occurrences.

Specific Ouestions 4

1.

Proposed TS Section 2.1. " Criticality Limit" Since this amendment is for " Possession-only," would a better title for this section be " Authorized Activities?"

I 2.

Prooosed TS Section [Q,3. " Irradiated Fuel Storaae and Transfer" Please clarify the terms in this specification with regard to " assemblies" and " elements."

3.

Fiaure 1. Section 11.0. " Administration" Please provide an updated Organizational Structure. This figure is adequate if only the titles are given.

4.

Proocsed TS Sections 11.4.2.4)c) and 15.1.4 Since changes to possession-only licenses can now be made through the 50.59 procedures, section 16 is no longer needed and the references to this section in these sections should be deleted.

5.

Proposed TS Section 16.0 Since changes to possession-only licenses can now be made through the 50.59 procedures, section 16 is no longer needed and should be deleted.

i a

a s

r e

i l

6.

Proposed TS Section 15.3 l

l This section should be rewritten as follows: A written report shall be l

forwarded within 30 days to the Director, Office of Nuclear Reactor Regulation with a copy to the Regional Administrator Region I in the event of---

l l

CERTIFIED FUEL HANDLER RECERTIFICATION PROGRAM Section 4.0 1.

How many questions will be on the written exam in Section 4.17 2.

An oral exam, to be given annually, should also be included in this l

section, including the provision for failure to pass the oral exam.

i 1

i I

1