e t

i j

l GPU Nuclear. Inc.

\\

Route 441 South NUCLEAR Post Office Box 480 Middletown, PA 17057-0480 Tel717 944 7621 December 05, 1996 6710-96-2399 U. S. Nuclear Regulatory Commission l

Attn: Document Control Desk Washington, D. C. 20555 Gentlemen:

4 4

Subject:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Response to Inspection Report 50-289/95-16 Reply

References:

(1)

NRC Letter dated March 11,1996, " Notice of Violation (NRC Inspection Report No. 50-289/95-16)."

(2)

GPU Nuclear Letter 6710-96-2024, dated April 10,1996,

" Response to Notice of Violation."

(3)

NRC Letter dated October 29,1996 (received i

November 6,1996), " Inspection Report 50-289/95-16 Reply."

Attachment I to this letter provides GPU Nuclear's response to your Reference 3 request to provide "..a specific reference to the section of ASME Section XI that allows the use of engineering judgment in lieu of code specified acceptance criteria, and an explanation of how your current ASME Section XI implementation program precludes situations similar to the RCS drain line."

Sincerely, J. Knubel p'

4-Vice President and Director, TMI y

cc:

TMI Senior Resident Inspector TMI-l Senior Project Manager g

Region Administrator

\\

9612170168 961205 PDR ' ADOCK 05000289 G

PDR

l f

ATTACHMENTI This attachment provides GPU Nuclear's response to your Reference 3 request to provide "...a specific reference to the section of ASME Section XI that allows the use of engineering i

judgment in lieu of code specified acceptance criteria, and an explanation of how your current ASME Section XI implementation program precludes situations similar to the RCS drain line."

At the time of the subject violation, the ASME Section XI code of record applicable to TMI was ASME Section XI 1977 Code through the 1978 Summer Addenda. This code version provided no acceptance standards for component supports. GPU Nuclear used engineering judgment in the evaluation of the RCS drain line supports. Please recognize that at that time no code acceptance criteria or specific code requirements then existed and therefore engineering judgment was not used

"...in lieu of code specified acceptance criteria." GPU Nuclear agrees that no editions of ASME Section XI specify that engineeringjudgment can be used "in lieu of code specified acceptance criteria." GPU Nuclear reaffirms that engineering judgment was not used "...in lieu of codes specified acceptance criteria."

The code of record for the current TMI ASME Section XIimplementation program is ASME Section XI 1986. The 1986 Edition of ASME Section XI, subsection IWF-3410, provides acceptance standards for inspecting component supports. Therefore, GPU Nuclear will continue to comply with the current code of record which requires unacceptable-conditions to be replaced, repaired, or demonstrated to meet functional requirements through testing or evaluation (IWF-3410).

To clarify GPU Nuclear's position as stated above, the response to Reference 2, Violation B, first paragraph, last sentence, is modified to read: "GPU Nuclear maintains that the use of engineering judgment to evaluate existing conditions rmder the TMI ASME Section XI implementation program is acceptable only when no code specified acceptance criteria or specific code requirements exist."

l 1

References (1)

NRC Letter dated, March 11,1996, " Notice of Violation (NRC Inspection Report No.

.l 50-289/95-16)."

(2)

GPU Nuclear Letter 6710-96-2024, dated April 10,1996," Response to Notice of Violation."

(3)

NRC Letter dated October 29,1996, (received November 6,1996), " Inspection Report 50-289/95-16 Reply."

l 1

l i

METROPOLITAN EDISON COMPANY JERSEY CENTRAL POWER AND LIGHT COMPANY PENNSYLVANIA ELECTRICAL COMPANY GPU NUCLEAR CORPORATION Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Reply to NRC Letter dated October 29,1996, (received November 6,1996),

{

" Inspection Report 50-289/95-16 Reply" l

i This letter is submitted in reply to NRC Letter dated October 29,1996, (received November 6, 1906), " Inspection Report 50-289/95-16 Reply", which requested additional infonnation in reference to NRC Letter dated March 11,1996, " Notice of Violation (NRC Inspection Report.

No. 50-289/95-16)." All statements contained in this reply have been reviewed, and all such statements made and matters set forth therein are true and correct to the best ofmy knowledge.

J. Knubel Vice President and Director, TMI-l Signed and sworn before me this 3

day of [

>- ]>>>

1996 9

_, MyMOU E pudtic 1

suzanne C V -[.,cn!n Cour.tY yy

[y[c TCf h ' '

l hemtof. Pennyv'a@ cst.on ut N09MS