SA R A DS p a g o) l 0:GMB Mr. Blake R. Williams Manager. Transportation Management Site and Transportation Services Nuclear Assurance Corporation 655 Enginering Drive. Suite 200 t!PON REMOVAL OF ATTACHMENT Tills DDCUMENT IS:
Norcross, GA 30092 duon+roMad
Dear Mr. Williams:
g j gg, This is in regard to your request dated November 4. 1996, for approval of a route to be used for trans) ort of spent fuel from McMaster University.
Hamilton, Ontario. to the Jepartment of Energy's Savannah River Site near Aiken South Carolina, The route, as set forth in Enclosure 1. meets the regulatory requirements of 10 CFR 73.37. constitutes approval for this route.
Unless renewed, this route approval will expire two years from the date of this letter.
Note that transportation of licensed radioactive material must be conducted in compliance with the applicable U.S. Department of Transporta-tion regulations.
NRC staff have completed the arrangements with law enforcement agencies required by 10 CFR 73.37(b)(6).
Note that armed escorts are required for the urbanized areas of Buffalo, New York: Erie and Pittsburg, Pennsylvania:
Charleston West Virginia: Charlotte, North Carolina; and Columbia, South Carolina.
Information on law enforcement arrangements is provided in, and is to be incorporated into your shipment plans and provided to your carrier along with instructions regarding its use.
If your carrier deviates from the a) proved route, please 3rovide details of the deviation to the contact listed Jelow as soon as possi]le.
The notification requirements of 10 CFR 73.37(f) and 73.72 ap31y for each shipment. When making notification to this office under 10 C R 73.72, please confirm that armed escort will be provided as required, and that the appro-priate governors or designees will or have been notified.
Should you require additional information or have questions concerning this matter, please contact John R. Cook of my staff at (301) 415-8521.
Sincerely, 9612160408 961211 Susan F. Shankman. Chief
[
PDR ADOCK 07003020
-ransportation Safety & Ins)ection Branch 1
C PDR 3 pent Fuel Project Office.
4 MSS Docket No. 70-03020
Enclosures:
l As stated
\\
OFC SFP0 SFP0 $
SFP0,_
SPAOR /
NAME MGMBennington JRC M EEas h S$nban DATE 12//0/96 12/@/96 12/le/96 12////65 0FFICIAL RECORD COPY C = COVER E = COVER & ENCLOSURE N = NO COPY 1
00 g4 cumen ansmitted Herewith s
n
.A An Contains Safeguards Informatiorf l-
s.
MCMASTER/SRP (#186)
{
DISTRIBUTION:
w/ enclosures:
w/o enclosures:
Docket File 07003020 NMSS R/F SFP0 R/F Case File 07003020F20R RFonner MRodgers i
Region I. 11 MMessier TAC-L22362 PDR (Enclosure 1)
CPaperiello t
1 i
j l
I l
i l
I l
l..
I f*pu n e e,
i e
o 0
i
)
E 5
/
- %, * + + /
4 i
SPENT FUEL PROJECT OFFICE i
NUCLEAR MATERIAL SAFETY AND SAFEGUARDS DECEMBER 1996 I
IRRADIATED REACTOR FUEL ROUTE
SUMMARY
MCMASTER UNIVERSITY. HAMILTON ONTARIO. CANADA l
TO DOE SAVANNAH RIVER PLANT SC ROUTE (186)
H l
i R
190)
{\\,
b l
\\
i y
19 t,
s.
J
.VA i
l 1
9]
4 Page 1 of 2
~. ~...
~
s ROUTE MILEAGE
SUMMARY
MCMASTER UNIVERSITY. HAMILTON ONTARIO. CANADA TO DOE SAVANNAH RIVER PLANT, SC STATE WAYPOINT/ INSTRUCTION ROAD DIR TOWARDS MILES TO CUMULATIVE NEXT MILES WAYPOINT NY DEPART CANADA VIA I-190 S/E BUFFALO 8
0 PEACE BRIDGE NY TAXE I 90 TO PA LINE I-90 W
PENSYLVANIA 70 8
llNE NY STATE MILEAGE SUBT0TAL 78 PA STAY ON 1 90 1 90 W
ERIE 27 78 PA TAKE I-79 TO WEST I-79 5
WEST 177 105 VIRGINIA VIRGINIA LINE PA STATE MILEAGE SUBTOTAL 204 WV CONTINUE ON 1-79 l-79 5
CHARLESTON 162 282 WV TURN ON l-77 1-77 S
OAKVALE 95 444 WV TAKE EXIT 9 TO US-460 US 460 E
PRINCETON 8
539 EAST WV GO TOWARDS PEARISBURG US 219 E
VIRGINIA 4
547 LINE WV STATE MILEAGE SUBTOTAL 269 VA STAY ON US-219 US-219 E
RADFORD 11 551 VA TAKE VA-100 VA-100 N/S DUBLIN 22.5 562 VA STAY ON VA-100 VA-100 SE WYTHEVILLE 11 584 5 VA TAKE I-81 TO I 77 1-81 SW WYTHEVILLE 8
595.5 INTERSECTION VA TURN ON 1-77 1 77 SE NORTH 32 603.5 VA STATE MILEAGE SUBTOTAL 84.5 NC CONTINUE ON 1 77 I 77 5
SOUTH 104 635.5 CAROLINA LINE NC STATE MILEAGE SLET0TAL 104 SC STAY ON 1-77 1-77 5
COLUMBIA 73 739 5 SC TURN ON 1-20 1 20 W
AIKEN 54 812 5 SC TAKE SC-19 SC-19 5
FACILITY 20 866 5 SC STATE MILEAGE Sl2 TOTAL 147 ROUTE TOTAL 886.5 Page 2 of 2