ML20129H229

From kanterella
Jump to navigation Jump to search
Forwards Unit 2 Cycle 7 Operating Limits Rept, Per GL 88-16
ML20129H229
Person / Time
Site: Byron 
Issue date: 09/30/1996
From: Kofron K
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20129H233 List:
References
BYRON-96-0253, BYRON-96-253, GL-88-16, NUDOCS 9610080059
Download: ML20129H229 (2)


Text

._. __.

Commonwcalth Edimn Company Ilynm Generating Station e

j 4 ISO. North German Church Road

)

lipun.11. 61014979 i Td HISE 6-5 t il September 30,1996 LTR:

BYRON-96-0253 i

File:

1.02.1052.174 Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555-001 ATTN:

Document Control Desk

SUBJECT:

Byron Unit 2 Cycle 7 Operating Limits Report Byron Nuclear Power Station Unit 2 Facility Operating License NPF-66 NRC Docket Number: 50-455 Byron Unit 2 has recently completed its 6th cycle of operation and is currently preparing for Cycle 7 startup (estimated startup date is October 3,19%). The purpose of this letter is to adsise you of Commonwealth Edison's (Comed's) review of the Cycle 7 reload under provisions of 10CFR50.59 and to transmit the Operating Limits Report (OLR) for the upcoming cycle consistent with Generic Letter 88-16.

The Byron Unit 2 Cycle 7 core, which consists of NRC approved fuel designs, was designed to operate within approved fuel design criteria, Technical Specifications and related bases such that:

i 1) core operating characteristics will be equivalent to or less limiting than those previously reviewed and accepted; or 2) re-analyses or re-evaluations have been performed to demonstrate that the limiting postulated UFSAR events which could be affected by the reload are within allowable limits.

Consistent with past reloads, the reload licensing analyses performed for Cycle 7 utilized NRC-approved methodologies. The fresh fuel to be loaded in Cycle 7 consists of 84 VANTAGE 5 fuel assemblies. There are 20 Region 9A assemblics with 4.80 w/o enrichment and 64 Region 9B assemblies with 4.60 w/o enrichment. The cycle-specific power distribution limits for Cycle 7 are presented in the attached OLR.

Comed has performed a detailed review of the relevant reload licensing documents, the associated bases, and references. Based on that review, a safety evaluation was prepared, as required by 10CFR50.59, which concluded that the reload presents no unreviewed safety questions and requires no Technical Specification change. The Byron On-site Resiew of the reload 10CFR50.59 Safety Evaluation has been completed in accordance with station procedures.

Finally, further verification of the reload core design will be performed during startup testing. The startup tests will be consistent with Technical Specifications and testing recommended in ANS 19.6.1.

()'"'.1 f ~ ~ 9610000059 960930 PDR ADOCK 05000455 1 \\

p PDR h*

\\

(pd96bylW960253 docW93096)

A t'nicom Company

e Byron Ltt: 96-0253 September 30,1996 Page 2 If there are any questions regarding this submittal, please contact Marcia Lesniak, Licensing Administrator, at (630)663-6484.

Sincerely,

'B

k. L. Kof on Station Manager Byron Nuclear Power Station KLK/rp Attachment cc:

G. F. Dick, Byron Project Manager - NRR A. B. Beach, Regional Administrator - RIII S. D. Burgess, Senior Resident Inspector - Byron Office of Nuclear Facility Safety - IDNS i

t 4

(p:\\96byhrs'960253.docW93096)

'i

..