Press Release I-96-72 Re NRC Staff Issued Rept by Augmented Insp Team (Ait),Reviewed Four Events for Reactor Coolant Following Failure of RHR Pump at Plant
ML20129H022
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 10/30/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
References
PR-I-96-072, PR-I-96-72, NUDOCS 9610300330
Download: ML20129H022 (1)


Text

, _ . . . _ . _ . _ . _ . _ . . _ _ . _ _ _ _ _ . _ _ . . __._.._.._-_.m_...__. . . _ . . _ _ _ _ . . . . - -

4 e

i .'

b ), .

United States Nuclear Regulatory Commission Office of.Public Affairs, Region I 475 Allendale Road King of Prussia,- PA 19401 1 Phone: 610/337-5330 Fax: 610/337-5241

, Internet
dps@nrc. gov or nas@nrc. gov I

i I-96-72 October 30, 1996  ;

i

Contact:

Diane Screnci FOR IMMEDIATE RELEASE Neil A. Sheehan NOTE TO EDITORS:

The Nuclear Regulatory Commission staff has issued the report by the Augmented Inspection Team (AIT) that reviewed four events related to reactor coolant inventory control and the contingency plans for reliable reactor cooling following the i failure of one residual heat removal pump at Connecticut Yankee j Atomic Power Company's Haddam Neck nuclear plant. I The report is available from the Public Affairs Office, in the Public Document Room or on the internet at this address:

http://www.nrc. gov /OPA/ reports. 1 1

1 1

5 9610300330 961030 PDR PRESS R RQ-I-96-072 PDR 31000> eMt, oh 3