ML20129G026

From kanterella
Jump to navigation Jump to search
Forwards Topical Rept Evaluation of WCAP-14416, W Spent Fuel Rack Criticality Analysis Methodology. Rept Acceptable for Ref in Licensing Application
ML20129G026
Person / Time
Issue date: 10/25/1996
From: Collins T
NRC (Affiliation Not Assigned)
To: Thomas Greene
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Shared Package
ML20129G031 List:
References
TAC-M93254, NUDOCS 9610290282
Download: ML20129G026 (2)


Text

.-___ ___ _.___ _ _ _ . -

l s t uq

[ps nea t UNITED STATES g j t

NUCLEAR REGlJd' TORY COMMISSION WASHINGTON, D.C. 20555-0001

{

8 k, % . . jo October 25, 1996 Mr. Tom Greene, Chairman Westinghouse Owners Group ,

Westinghouse Electric Corporation ('

P.O. Box 355 Pittsburgh, PA 15230-0355 {

Dear Mr. Greene:

i f

SUBJECT:

ACCEPTANCE FOR REFERENCING OF LICENSING TOPICAL REPORT WCAP-14416-P,  ;

! " WESTINGHOUSE SPENT FUEL RACK CRITICALITY ANALYSIS METHODOLOGY" ,

(TAC NO. M93254)

I l The staff has reviewed the topical report submitted by the_ Westinghouse Owners  !

l Group by letter dated July 28, 1995, and supplemented by letter dated October i 18, 1996. The report is acceptable for referencing in license applications to  !

the extent specified and under the limitations stated in the enclosed U.S.

Nuclear Regulatory Commission (NRC) evaluation. The evaluation defines the  ;

L basis for acceptance of the report.

The staff will not repeat its review of the matters described in the report l and found acceptable when the report appears as a reference in license  :

applications, except to assure that the material presented applies to the  !

specific plant involved. NRC acceptance applies only to the matters described  ;

l in.the report. In accordance with procedures established in NUKEG-0390, the NRC requests that the Westinghouse Owners Group publish accepted versions of i the report, proprietary and non-proprietary, within 3 months of receipt of i this letter. The accepted version shall incorporate this letter and the l enclosed evaluation between the title page and the abstract and an -A l (designating accepted) should follow the report identification symbol.  !

( If the NRC's criteria or regulations change so that its conclusion that the [

l report is acceptable is invalidated, the Westinghouse Owners Group and/or the  ;

l applicant referencing the topical report will be expected to revise and l resubmit its respective documentation, or submit justification for the  !

! continued appilcability of the topical report without revision of the .

respective documentation.  !

a Since ely, s i Wk  %

T mothy E. {ollins, Acting Chief Reactor Systems Branch J O'3 / I Division of Systems Safety and Analysis i i

Enclosure:

(o-/$I l

WCAP-14416-P Evaluation gg twohqua 290055 9610290282 961025 PDR .TOPRP EMWEST PDR d ,

DISTRIBUTION PUBLIC ,[

Central FilesV Ringram GHolahan EWeiss TCollins CGratton BWetzel CCraig LKopp LKopp R/F SRXB R/F

- _ - _ _ _ _ _ _ _ _