Forwards Final Rept on Investigation of Failed Field Anchor Heads HV016 & HV038 from Jm Farley Nuclear Power Plant Unit 2 Containment & Anchor Head Investigation Final Rept. Rept Corrections Also Encl
Date released: 05/22/2020 Download: ML20129F600


Anchor Head Investigation, Final Rept
ML20129F633
Person / Time
Site: Farley 
Issue date: 07/10/1985
From: Budinger D, Henger G, Noe P
INLAND STEEL CO., PRECISION SURVEILLANCE CORP. (FORMERLY INRYCO, INC.)
To:
References
Download: ML20129F633 (71)
Final Rept on Investigation of Failed Field Anchor Heads HV016 & HV038 from Jm Farley Nuclear Power Plant Unit 2 Containment.
ML20129F611
Person / Time
Site: Farley 
Issue date: 04/09/1985
From: Groeneveld T
Battelle Memorial Institute, COLUMBUS LABORATORIES
To:
References
Download: ML20129F611 (42)
Forwards Final Rept on Investigation of Failed Field Anchor Heads HV016 & HV038 from Jm Farley Nuclear Power Plant Unit 2 Containment & Anchor Head Investigation Final Rept. Rept Corrections Also Encl
ML20129F596
Person / Time
Site: Farley 
Issue date: 07/10/1985
From: Mcdonald R
ALABAMA POWER CO.
To: VARGA S A
Office of Nuclear Reactor Regulation