ML20129F099

From kanterella
Jump to navigation Jump to search
EN-85-042:by 850530,notice of Violation & Proposed Imposition of Civil Penalties in Amount of $75,000 Will Be Issued.Action Based on Violations Re Health Physics & Security & Inadequate Mgt Control of Contractors
ML20129F099
Person / Time
Site: Peach Bottom, Limerick, 05000000
Issue date: 05/24/1985
From: Axelrad J, Robinson P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
References
EN-85-042, EN-85-42, NUDOCS 8506060681
Download: ML20129F099 (1)


Text

p$f i

May 24, 1985 EN 85-42

'0FFICE OF INSPECTION AND ENFORCEMENT'

-NOTIF CTION Licensee: _ Philadelphia' Electric Company Peach Bottom xUnit 2 and Limerick, Unit 1 Docket Nos. 50-277 and 50-352 Sub.iect:

PROPOSED IMPOSITION OF CIVIL PENALTIES - $75,000 This <is to inform the Comission that a Notice of Violation and Proposed

. Imposition of Civil: Penalties in the amount of Seventy-five Thousand Dollars 1($75,000) will be issued on'or about May 30, 1985 to Philadelphia Electric

Company.. This action is based on violations involving two nuclear sites,

' Peach Bottom and Limerick. The specific violations are related to health physics and security and arise from a common concern relating to inadequate, y

management control of licensed activities performed by contractors atLboth sites.

It should be noted that the~1icensee has not been specifically informed of the enforcement action. The Regional Administrator has been authorized by the Director, Office of Inspection and Enforcement, to sign-this action. The schedule of issuance and notification is:

Mailing-of Notice May 30, 1985 Telephone Notification of Licensee May 30, 1985 A news release has been prepared and will be issued about the time the

-licensee receives the Notice. The' State of Pennsylvania will be notified.

The licensee has thirty days from the date of the Notice in which to respond.

Following NRC evaluation of the response, the civil penalty may be~ remitted, mitigated, or imposed by Order.

Contact:

.P. Robinson, IE 29583 J. Axelrad, IE 24909 Distribution:

H Street -/,' do MNBB /!3 /

Phillips b 3(o EW Willste/ N Chairman FaTTadino EDO NRR IE NMSS I

Com. Roberts

_DED/ROGR OIA RES i

Comm. Asselstine-PA OI Comm. Bernthal=

ELD AE00 Comm. Zech RM i>

ACRS

! :~

SECY:

Air Rights /'I~0 Regional Offices MAIL

CA '

SP RI /!3r RIV /.V7 ADM: Doc. Mgt. Br.

RII W RV / / V 9 PDR L

PE

/

RIII /.6 f.

' PRELIMINARY INFORMATION - NOT FOR PUBLIC DISCLOSURE UNTIL MAY 30, 1985.

I h600681850524

' 7.

EN-85-042 pm '

(f O I