ML20129E699

From kanterella
Jump to navigation Jump to search
Forwards Supporting Info Re Radiological Programs & Trends to Facilitate Review of License Renewal Submittal
ML20129E699
Person / Time
Site: 07001113
Issue date: 09/26/1996
From: Reda R
GENERAL ELECTRIC CO.
To: Flack E
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 9610030251
Download: ML20129E699 (4)


Text

.g, 70-///3

-o

. GENuclearEnergy l

GerealElectric Cornpany 1

PO Box 180, Wilmington, ivc 28402 910 515 50i]O I

September 26,1996 i

Mr. E. D. Flack Licensing Branch, NMSS U. S. Nuclear Regulatory Commission l

Mail Stop T 8-D-14 l

Washington, D. C. 20555-0001

Subject:

Supporting Radiological Information for License Renewal l

References:

(1)

SNM-1097, Docket 70-1113 (2)

License Renewal & Letter, R. J. Reda to E. Q. Ten Eyck,4/5/96 l

(3)

Letter with Enclosures, R. J. Reda to E. D. Flack, 5/6/96 (4)

Phone Conversation, E. D. Flack and A. M. Mabry,6/20/96 i

Dear Mr. Flack:

Pursuant to the phone conversation referenced above, GE's Nuclear Energy Production facility in Wilmington, N. C. hereby transmits the enclosed supporting information regarding radiological programs and trends to facilitate your review of our license renewal submittal. This information is mtended to provide the details that you indicated would be needed to complete the review.

I is a written response to three specific requests for information, and enclosure 2 is l

two additional charts you requested summarizing radiological trends.

i Six copies of this submittal are being provided for your review. An additional copy is being sent I

to Region II.

l Please contact me on (910) 675-5889 or Allen Mabry on (910) 675-5601, if you would like to discuss this matter further.

Sincerely,

/

c

. J. Reda, Manager Fuels and Facility Licensing enclosures cc:

RJR-96-106 L

9610030251 960926 l

I't PDR ADOCK 07001113 C

PDR e l'

.~

= -.

4 P geIcfI September 26,1996 RESPONSES TO REOUESTS FOR INFORMATION REGARDING RADIOLOGICAL PROGRAMS Below are the requests followed by our responses.

l

1. Request: Provide action levels and actions based on individual airborne exposure assignments.

Response: W'ork activity restrictions are imposed when an individual's exposure exceeds 1600 DAC'hr in a year. Additionally, when an individual's exposure assignment exceeds 500 DAC*hr in a quarter the individual is temporarily restricted from controlled area work, an investigation is initiated and a whole body count is -

i scheduled.

2. Request: Provide for 1994 and 1995 the highest committed effective dose equivalent (CEDE) and the total number ofindividuals with a CEDE greater than 2 rem.

Response: The highest CEDES for 1994 and 1995 were 2.08 and 2.41 rem i

respectively. The total number ofindividuals with a CEDE greater than 2 rem for 1994 and 1995 were 1 and 9 respectively.

l

3. Reque=t: Provide for 1994 and 1995 the total number oflung counts performed and the highest lung burden assignments.

Recnnnee: Approximately 760 individuals were counted in 1994 and in 1995. More i

than 850 counts were performed in each of those years. During 1994 and 1995 restrictions ofindividuals occurred due to lung count results that exceeded administrative limits, but subsequent counts revealed none of the individuals had true l

lung burdens. No lung burdens were assigned during either year.

k i

l I

I

. - _ -. ~.... -

SKIN DOSE -- HIGHEST WORKER e

[ 1991-1995 ]

REM / YEAR so

lilll0 V

l l l

]

40 4o g

l l l

t lll1l l ljl lll l \\

\\

\\

l

\\

20 f

2o I

\\ \\;\\

l l 1

\\

l l

l l

ll i

t ll l

\\

o.76 o.91 o.67 o.89 1.11 lll lll 0

o

'91

'92

'93

'9'4

'95 NRC UMIT YEAR f

This chart represents the highest external skin dose assigned to any individual. The individuals with the highest l

external skin dose assignments typically work in the ceramic operations.

l l

i Page1of2 September 26,1996

[

r

  • te

-m_..-

......._.._.__...m.

._____.._._....._.__.m.m-_

..._.._m._...._m

.m.________.

ANNUAL AVG AIR CONCENTRATION BY AREA I

1993 1994 1996 E... 4

% DAC 50

-::9;'c' i

e 3o l

l 20

^

I N

.~

l

~:

..s' m

t CERAMIC POWDER PREP POWDER PROD AREA l

This chart represents the approximate annual average airborne concentrations as a percentage of the derived air

{

concentration (DAC) for the three main work areas of the facility. DACs are based on the values in 10 CFR 20 i

appendix B, Table 1, Col. 3 (effective 1/1/94). In certain areas the DAC is adjusted based on the actual physical j

characteristics of the airborne uranium in accordance with 10 CFR 20.1204(c)(2). In the Ceramic areas the predominant DAC is 4E-11 pCi/cc (Class Y adjusted for particle size), in the Powder Preparation areas it is 2E-11 pCi/cc (Class Y) and in the Powder Production areas it is 3E-10 pCi/cc (Class W).

[

Page 2 of 2 September 26,1996

- - -