p n Rf

BROOKHAVEN NATIONAL LABORATORY l

ASSOCIATED UNIVERSITIES, INC.

P.O. Box 5000 Upton, New York 11973-5000 TEL (516)282-4420 FAX (516)282 4486 Department of Advanced Technology E-M?ll June 30,1995 Mr. James A. Davis U.S. Nuclear Regulatory Commission NRR/EMCB Mail Stop 7-D4, Room 7-C23 Washington, D.C. 20555 i

Dear Sir:

Enclosed please find a copy of the final BNL Technical Report entitled

" Metallurgical Evaluation of a Feedwater Nozzle to Safe-End Weld from River Bend Station Unit 1." This transmittal satisfies Task Order No. 2, FIN E2089, Subtask No.

I Sa.

I If there are any questions, please contact me at the above numbers.

Very tfuly yours, l

C za k

Environmental & Waste Technology Center CJC/gw Enclosure I

cc:

M. Bonner

{

B. Grenier 300028 O

'D L

i 9609300178 950630 PDR ADOCK 05000458 P

PDR

){

4 1

TELEX: 6852516 BNL doe CABLE: BROoKLAB UPTONNY