4
, aft Kf Gg
[
UNITED STATES
,8 l ' s, y, ( j' g NUCLEAR REGULATORY COMMISSION (f
g j
WASHINGTON, D. C. 20555 g/.
/
\\,.s (/
July 1, 1985 MEMORANDUM FOR: Those on Attached List FROM:
Phillip F. McKee, Chief Operating Reactor Programs Branch Division of Inspection Programs Office of Inspection and Enforcement
SUBJECT:
REQUEST FOR COMMENT ON DRAFT IE INFORMATION NOTICE,
" SURVEYS OF WASTES BEFORE DISPOSAL FROM NUCLEAR REACTOR FACILITIES" The subject draft information notice is enclosed for your review.
The enclosed draft is a revision of an earlier draft that was discussed during a teleconference involving IE, NRR, and regior,al staff members on May 8, 1985.
The enclosed draft also has been discussed with the Director, IE, during a briefing on June 14, 1985.
We do not believe the current draft information notice is a backfit; however, CRGR will be given an opportunity to review the information notice before it is issued.
Comments received by July 15,1985 will be carefully considered.
If you have no comments, or minor comments, a telephone call will suffice.
l Phillip F. Md ee, Chief Operating Reactors Program Branch Division of Inspection Programs Office of Inspection and Enforcement
Enclosure:
Scotg 7664 " Post 4t" Routing-Request Pad Draft Information Notice ROUTING - REQUEST READ To hft Sl' 6)lL HANoLE 0 APPROVE M jg h /2/f 177p'f7 N>1 $ %k CONTACT:
John Buchanan, ORPB/IE
-~
O newaN (492-9657)
O xeeP on oiscano
$71g69B50701 C aEview WITH ME PDR n,,, %fLf( nohfEWkild MSC UGW 1
Addressees for Memorandum dated:
July 1, 1985 R. R. Bellamy, Chief Emergency Preparedness and Radiological Protection Branch Region I D. M. Collins, Chief Emergency Preparedness and Radiological Protection Branch Region II C. J. Paperiello,. Chief Emergency Preparedness and Radiological Protection Branch Region III R. E. Hall, Chief Emergency Preparedness and Radiological Protection Branch Region IV F. A. Wenslawski, Chief Emergency Preparedness and Radiological Protection Branch Region V F. Congel, Chief Radiological Assessment Branch Division of Systems Integration Office of Nuclear Reactor Regulation L. B. Higginbotham, Chief Low-Level Waste Licensing Branch Division of Waste Management Office of Nuclear Material Safety and Safeguards 9
h
July 1, 1985 d
MEMORANDUM FOR:
Those on Attached List FROM:
Phillip F. McKee, Chief Operating Reactor Programs Branch Division of Inspection Programs Office of Inspection and Enforcement
SUBJECT:
REQUEST FOR COMMENT ON DRAFT IE INFORMATION NOTICE,
" SURVEYS OF WASTES BEFORE DISPOSAL FROM NUCLEAR REACTOR FACILITIES" The subject draft information notice is enclosed for your review.
The enclosed draft is a revision of an earlier draft that was discussed during a teleconference involving IE, NRR, and regional staff members on May 8,1985.
The enclosed draft also has been discussed with the Director, IE, during a briefing on June 14, 1985.
We do not believe the current draft ir. formation notice is a backfit; however, CRGR will be given an opportunity to review the information notice before it is issued.
Comments received by July 15,1985 will be carefully considered.
If you have no comments, or minor comments, a telephone call will suffice.
Phillip F. McKee, Chief Operating Reactors Program Branch Division of Inspection Programs Office of Inspection and Enforcement
Enclosure:
Draft Infonnation Notice CONTACT: John Buchanan, ORPB/IE (492-9657)
DISTRIBUTION:
DCS-016 ORPB Reading DI Reading EFBranagan, Jr., NRR PFMcKee LJCunningham JBuchanan DAllison REAlexander, RES ELJordan JGPartlow RHVollper ID IE PB I.
B
- esp LJCunningham McKee 6,Gue G.
dow
~
/f4/85 6fC/85 6/7) /85 G/
/05
'Q/
'/65
M 2 01985 UNITED STATES
- NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, DC 20555 IE INFORMATION NOTICE NO. 85-XX:
SURVEYS OF WASTES BEFORE DISPOSAL FROM NUCLEAR REACTOR FACILITIES Addressees:
All production and utilization facilities, including nuclear power reactors and research and test reactors, holding an operating license (OL) or Construction permit (CP). '
Purpose:
The purpose of this information notice is to update the guidance of IE Circular 81-07 as it applies to surveys of solid waste materials before disposal from nuclear reactor facilities.
It is expected that recipients will review the in-formation for applicability to their facilities.
No specific action or licensee response is required.
Description of Circumstance:
Some questions have arisen concerning acceptable methods of surveying solid waste materials before releasing them as non-radioactive (i.e., as wastes that do not contain NRC-licensed material).
h
[
Discussion:
1 As emphasized in IE Information Notice 83-05, existing NRC regulations, with one exception, provide no minimum level of radioactivity in waste from a licensees facility that may be disposed of in a manner other than as normal radioactive waste in accordance with 10 CFR Section 20.301.
The one excep-tion is the provision in 10 CFR Section 20.306 that certain levels of tritium and carbon-14 in certain materials may be disposed of without regard to its radioactivity.
Also, as emphasized in IE Information Notice No. 83-05, licen-sees may request NRC approval of alternative methods of disposal in accordance with 10 CFR Section 20.302.
A practical consequence of these current regula-tions is that a licensee who does not have specific NRC approval to dispose of materials by alternative methods must dispose of material contaminated with de-tectable licensed material at a licensed waste burial site.
However, material that is contaminated with licensed material at detectable levels may be disposed by other methods if NRC approval has been obtained in accordance with 10 CFR section 20.302.
Requests for approval may be either for disposal of a particu-lar quantity of a particular material on a one-time basis or the request may be for continuing disposal of specific types of wastes on an annual basis using ap-proved procedures and systems.
Requests from reactor licensees for approval of alternative methods of disposal should be directed to the Office of Nuclear Reactor Regulation (NRR).
The Office of Inspection and Enforcement and the NRC Regional Offices have no authority to approve such requests.
One misunderstanding of NRC requirements is the belief that if a licensee estab-lishes specific release limits in the licensee's operating procedures, these con-tamination limits become legally acceptable.
As discussed above, material con-taminated with detectable licensed material may not be released from licensee control without specific NRC authorization.
Therefore, in the absence of NRC approval, procedures containing release limits (i.e., procedures allowing the release of material known to be contaminated) would be procedures for activities HAFI
/
that are contrary to NRC regulations.
Plant procedures may, however, incorporate detection limits for survey equipment used to search for and measure radioactive contamination in material being surveyed before release from licensee control.
Minimizing the volume of radioactive waste generated and shipped to commercial waste burial sites is a need recognized by the NRC.
Some nuclear power plants have initiated programs to segregate waste generated in radiologically controlled areas.
Such programs are encouraged by the Institute for Nuclear Power Operations (INPO) which has included guidance on segregatiogof materials in its good prac-2 tice document on low-level radioactive waste management.
The INP0 guidance on segregation of materials quite properly includes the " caution" that " care should be taken to ensure that no radioactive material is released." As mentioned previously this means in practice that no radioactive material that is detect-able can be released.
This requires careful surveys and monitoring using ap-propriate radioactivity detection and measurement equipment and techniques.
3 In 1981, I.E. Circular No. 81-07 was issued by the NRC.
That circular pro-vided guidance on the control of radioactively contaminated material and iden-tified how hard licensees should look for contamination.
These criteria addres-sed surface contamination levels, were based on the best information available at the time, and were related to the capability of portable survey instruments equipped with thin-window " pancake" G.M. probes.
Monitoring of aggregated, pack-aged material was not addressed.
At the time, in 1981, there was no major empha-sis on segregating waste from designated contamination areas.
As a consequence, large volumes of monitored wastes were not being released for unrestricted dis-posal.
However, today's practices at many nuclear power facilities result in large volumes of segregated, monitored wastes being released as " clean" waste Under these conditions, it is not appropriate to survey for surface contamination only; in addition, surveys of aggregated wastes should be performed with gamma-sensitive fixed or portable instruments (for example, instruments using sensitive scintillation detectors).
s O
[
Guidance:
s 1.
Materials that may be contaminated, and that are to be disposed of without specific NRC approval, should be carefully surveyed using methods (equip-ment and techniques) for detecting very low levels of radioactivity.
These survey methods should provide licensees with reasonable assurance that li-censed material is not being released fro'n their control.
2.
Surveys conducted with portable survey instruments utilizing " pancake" G.M.
probes are more appropriate for small items and small areas because of the loss of detection sensitivity created by moving the probe and the difficult-ies in completely scanning large areas.
This does not preclude their use for larger items and areas if supplemented by other survey equipment or techniques.
3.
Final measurements of aggregated wastes should be performed to ensure that there has not been an accumulation of licensed material resulting from a buildup of multiple non-detectable quantities (for example, final measure-ments using sensitive scintillation detectors in low-background areas).
No specific action is required by this information notice.
If you have any questions about this matter, please contact this office or the Radiological Assessment Branch, Office of Nuclear Reactor Regulation (NRR).
Edward L. Jordan, Director Division of Emergency Preparedness and Engineering Response Office of Inspection and Enforcement Technical Contacts:
John D. Buchanan, IE (301) 492-9657 Edward E. Branagan, Jr. NRR (301) 492-7614 Attachments:
1.
References 2.
List of Recently Issued IE Information Notices MAFT
+
y IN 85-XX Page 1 of 1 REFERENCES 1.
IE Information Notice No. 83-05, " Obtaining Approval for Disposing of Very Low-Level Radioactive Waste--10 CFR S24302," February 24, 1983.
~
2.
" Low-Level Radioactive Waste Management," Institute of Nuclear Power Operations (INPO) Good Practice document, INPO 82-001; OEN-09; September 1982.
3.
IE CircuTar 81-07, " Control of Radioactively Contaminated Material," May 14,
~
1981.
O e
h Y
[-
HAFT