RBG-21125, Responds to NRC Requesting Addl Info Re Violations Noted in Insp Rept 50-458/85-10.Corrective Actions:Qa Performed Unscheduled Surveillance of Well Rod Issue Stations 1 & 3 on 850503

From kanterella
(Redirected from ML20129C417)
Jump to navigation Jump to search
Responds to NRC Requesting Addl Info Re Violations Noted in Insp Rept 50-458/85-10.Corrective Actions:Qa Performed Unscheduled Surveillance of Well Rod Issue Stations 1 & 3 on 850503
ML20129C417
Person / Time
Site: River Bend 
Issue date: 05/28/1985
From: Deddens J
GULF STATES UTILITIES CO.
To: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20129C387 List:
References
RBG-21125, NUDOCS 8507290428
Download: ML20129C417 (3)


Text

r e

ab GULF STATES UTILITIES COMPANY RrVER BEND STATION POST OFFICE BOX 220 ST FRANCISVILLE. louts 1ANA 70775 ARE A CODE 504 635-6094 346-8651 May 28, 1985 RBG-21125 File Nos. G9.5, G15.4.1 Mr. Robert D. Martin, Regional Administrator -

bb$D U. S. Nuclear Regulatory Commission Region IV i

g,,4 g j

611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 y

i p

Dear Mr. Martin:

River Bend Station - Unit 1 Refer to:

RIV Docket No. 50-458/ Report 85-10 This letter is in response to your letter dated May 7, 1985, which requested additional information concerning the Notice of Violation 85-10-02, " Compliance with Welding Control Procedure Requirements,"

contained in NRC I6E Inspection Report No. 50-458/85-10. The inspection was conducted at the River Bend Station construction site by Messrs.

W. M. McNelli and I. Barnes during the period February 4-8, 1985, of activities authorized by NRC Construction Permit CPPR-145 for River Bend Station Unit No. 1.

'Ihe following information addresses the actions being taken to assure that station attendant-prepared Construction Completion Checklists (CCC) accurately reflect performance of their duties. GSU Quality Assurance performed an unscheduled surveillance of Weld Rod Issue Stations 1 and 3 on May 3, 1985. During the surveillance it was observed that the Weld Rod Station Attendants maintain a daily log of the temperature checks made during the day of the rod storage ovens and portable electric rod heaters in addition to the preparation of CCC's.

The Construction Welding Supervisior or his designee reviews and signs the daily log and the com-pleted CCC. Also, FQC routinely checks the Weld Rod Issue Stations and prepares an Iaspection Report documenting the results of their inspection.

%[

p G

y/

(C'0@"

r-s Page 2 May 28, 1985 RBG 21125 The review performed by the Construction Welding Supervisor or his designee of the daily log prepared by the rod station attendant, in ad-

.dition to the completed CCC, provides assurance that management is aware that the rod ovens and portable electric heaters are maintained within the required temperature range and that proper environmental control are imposed on the Weld Filler Materials at the Weld Rod Issue Stations.

This concludes our response to your request for additional information concerning this' Notice of Violation.

Sincerely, J. C. Deddens Vice President River Bend Nuclear Group

-[Yq,,

r JCD/TCC/PJD/amg i

l I

4 i

(

UNITED STATES OF AMERICA NUCLEAR REGULATORY ColetISSION STATE OF LOUISIANA 5

PARISH OF WEST FELICIANA 5

In the Matter of I

Docket Nos. 50-458 50-459 CULF STATES UTILITIES COMPANY (River Bend Station, Unit 1)

AFFIDAVIT J.

C.

Deddens, being duly sworn, states that he is a Vice President of Gulf States Utilities Companyi that he is authorized on the part of said Company to sign and file with the Nuclear Regulatory Commission the documents attached heretos and that all such documents are true and correct to the best of his knowledge, information and belief.

J. t. Deddens Subscribed and sworn to before me, a Notary Public in and for the StateandParishabovenamed,thisOk ay of md_ U

,19R5.

7 04.Middlebroo(sA/ llc w

  1. otaryPublicinandfor~~

an W West Feliciana Parish, Louisiana My Commission is for Life.

<