_ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ - _ _
8"
g UNITED STATES NUCLEAR REGULATORY COMMISSION o
h WASHING TON, D. C. 20555 o
July 24, 1985 Docket No. 99900741/85-01 Power Conversion Products, Inc.
ATTN: Mr. C. F. Seyer Executive Vice President 42 East Street Post Office Box 380 Crystal Lake, Illinois 60014 Gentlemen:
This refers to the inspection conducted by Mr. K. R. Naidu of this office on May 22-23, 1985, of your facilities located at Crystal Lake, Illinois, and to the discussions of our findings with you and your QA Manager at the conclusion of the inspection.
The purpose of this inspection was to review the implementation of your Quality Assurance Program and corrective action taken relative to 10 CFR Part 21 reports.
Areas examined during the inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room, Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, gy A Oh Gary G. Zech, Chief Vendor Program Branch
)
Division of Quality Assurance, Vendor and Technical Training Center Programs i
Office of Inspection and Enforcement ppend x
- Inspection Report 99900741/85-01 f
I 8507290423 850724 9
4 PROCeBSDIS h00 9 ENVP R
tr.samal document not avails!Ao to MEC Oertified bFb1AAA L b
(
Power Conversion Products, Inc.
July 24, 1985 Distribution DMB-IE:09 VPB Reading DQAVT Reading RVollmer JTCollins JStone GHolahan, NRR Region III EMerschoff KNaidu VYB:DQAVT PB:DQAVT B VPB:DQAVT P
AVT KNaidu:gmk erschoff GZech B rimes
-}///85
'F/3/85 4/ (q/85
- g85
.