ML20128Q698

From kanterella
Jump to navigation Jump to search
Responds to FOIA Request for from GG Sherwood to Hl Thompson on Review of Leak-Before-Break Approach on Gessar II Docket. Forwards Document
ML20128Q698
Person / Time
Site: 05000447
Issue date: 06/19/1985
From: Felton J
NRC OFFICE OF ADMINISTRATION (ADM)
To: Nagata P
ABB IMPELL CORP. (FORMERLY IMPELL CORP.)
References
FOIA-85-412 NUDOCS 8507270035
Download: ML20128Q698 (1)


Text

.

})h

%'n UNITED STATES

?

NUCLEAR REGULATORY COMMISSION h

WASHINGTON, D. C. 20555

%,..... f M 1 S 1985 Mr. Peter K. Nagata Impell Corporation 2345 Waukegan Road IN RESPONSE REFER Bannockburn, IL 60015 TO F01A-85-412

Dear Mr. Nagata:

This is in response to your letter dated June 6, 1985, in which you requested, pursuant to the Freedom of Information Act, a copy of the April 4, 1985, letter from Glenn G. Sherwood (General Electric) to H. L. Thompson, Jr.

(Nuclear Regulatory Comission), subject: " Review of Leak-Before-Break approach on GESSAR II Docket," PDR 8506140422.

A copy of the requested letter is enclosed.

~

Si

rely, J<

. Felton, Director

@visionofRulesandRecords Office of Administration

Enclosure:

As stated 8507270035 850619 NA ATA

-412 PDR

Ci.UAAL $ ELECTRIC NUCLEAR SYSTEMS TECHNOLOGY OPERATION GENERAL ELECTRIC COMPANY + 175 CURTNER AVENUE, M/C

  • SAN JOSE, CAUFORNIA 95195 (408)925-

~

April 4, 1985 MFNi 049-85 U. S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, D.C. 20555 Attention:

H. L. nompson Jr., Director Division of Licensing i

Gentlemen:

SUBJECT:

IN THE MATTER OF 238 NUCLEAR ISLAND GENERAL ELECTRIC i

STANDARD SAFETY ANALYSIS REPORT (CESSAR II)

DOCKET NO. STN 50-447 REVIEW OF LEAK-BEFORE-BREAK APPROACH ON GESSAR II DOCKET

Reference:

J. F. Quirk to Cecil 0. Thomas, " Submittal of Draft Amendment supporting Leak-Before-Break Approach",

January 31, 1984 MFN-011-84 i

Please be advised that GE is preparing to update and resubmit the reference January 31, 1984 draft supporting the Leak-Before-Break (LBB) approach to make it consistent with the requirements of the recently issued NUREG-1061. Volume 3.

De original submittal was limited to stainless steel piping. The first update will also be limited to stainless steel piping. A separate similar submittal will be made for qualifying carbon steel piping.

?

The schedule proposed below has been developed in conjunction with an I

applicant for a BWR operating license, who intends to apply the LBB approach if it is near-term cost-effective (i.e., if the schedule for technical and licensing efforts will support his near-tern plant i

construction schedule).

J 1.

GE resubmit for stainless steel piping 4/26/85 l

I 2.

GE submit for carbon steel piping 6/18/85 f

l 3.

NRC Safety Evaluation Report 9/1/85 1

d 2pp t

h

r

)

i C

l t

The stainless steel and carbon steel submittals will be comprised of two parts: (1) methodology suitable for all BWR and containment types; and (2) application of the methodology to the GESSAR II design.

The' methodology portions will be written suitable for reference by BWR owners or applicants who choose to apply the LBB approach.

If you have any questions, please contact me (408) 925-5040 or Rs: Villa (408) 925-5722 of my staff.

Sincerely,

,/Gkh bdb -,pAh Glenn G. Sherwood, Manager Nuclear Safety & Licensing Operation cc:

J. A. O'Brien l

D. C. Scaletti dB. D.-Lisw L. S. Gifford D. L. Murray C. O. Thomas i

i i

1

!