Provides Addl Info Re Draft SER Item 101, Inadvertent Boron Dilution. Failure Mode Analysis for Chemical & Vol Control Sys Performed.Results Indicate Corrective Actions Meet Acceptance Criteria of SRP Section 15.4.6
ML20128Q461
Person / Time
Site: Vogtle  
Issue date: 05/29/1985
From: Bailey J
GEORGIA POWER CO.
To: Adensam E
Office of Nuclear Reactor Regulation
References
0205M, 205M, GN-629, NUDOCS 8506040203
Download: ML20128Q461 (1)


Text

GeorgLn Power Company Rout 3 2 Box 299A Waynesboro. Georgi 130830

. Telephone 404 554 9961 404 724-8114 Southern Company Services,Inc.

Post Office Box 2625 ~

Birmingham, Alabama 35202 Telephone 205 870{011 Vogtle Proj,ect May 29, 1985

. File: X7BC35

Director of Nuclear Reactor Regulation Attention:

Ms. Elinor G. Adensam, Chief Log:

GN-629 Licensing Branch #4 Division of Licensing U. S. Nucle ~ar Regulatory Commission Washington, D.C.

20555 NRC DOCKET NUMBERS 50-424 AND 50-425 CONSTRUCTION PERMIT NUMBERS CPPR-108 AND CPPR-109 V0GTIE ELECTRIC GENERATING PLANT - UNITS 1 AND 2 REQUEST FOR ADDITIONAL INFORMATION: DSER OPEN ITEM 101

Dear Mr. Denton:

,Concerning DSER Item 101, Inadvertent Boron Dilution, we have performed a.

failure mode analysis for the chemical and volume control' system which de.monstrates that the calculated minimum time intervals available (time interval-between an alarm announcing an unplanned moderator dilution and the time of loss of shutdown margin) for the operator to take appropriate corrective actions will meet the acceptance criteria of SRP Section 15.4.6, i.e., at least 15 minutes. The' primary instrument used to detect this event is the' safety-grade source range. The FSAR will be revised

'accordingly via FSAR Amendment 17, which is scheduled for July 1985.

If your staff requires any additional information, please do.not hesitate to contact me.

Sincerely, 4

J. A. Bailey Project Licensing Manager 4