ML20128Q390
| ML20128Q390 | |
| Person / Time | |
|---|---|
| Issue date: | 08/30/1996 |
| From: | Taylor J NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO) |
| To: | |
| References | |
| SECY-96-189, SECY-96-189-R, NUDOCS 9609090046 | |
| Download: ML20128Q390 (40) | |
Text
{{#Wiki_filter:_ - _ - _ _ _ _ _ _ 00000000000000000000000o s RELEASED TOTHE PDR
- s lC Yb h& J e f
3 datd initia sneeeeeeeeeeeeeeeeels l z ese. (*****,/ August 30, 1996 SECY-96-189 POLICY ISSUE [gg-The Commissioners (Notation Vote) faQM: James M. Taylor Executive Director for Operations
SUBJECT:
ISSUANCE OF 10 CFR 50.54(f) LETTERS ON THE AVAILABILITY AND ADEQUACY OF DESIGN BASES INFORMATION PURPOSE: To request the Commission's approval of the staff's proposal,to send 10 CFR 50.54(f) letters to utility chief executive officers (CE0s). These letters will require information that will provide the U.S. Nuclear Regulatory Commission (NRC) added confidence and assurance that plants are operated and maintained within the design basis of the plant and any deviations are reconciled in a timely manner.
SUMMARY
Recent NRC inspection findings have indicated that design bases information has not been appropriately maintained and implemented at certain plants and that this may have a potential impact on public health and safety. The staff is proposing to require information from licensees regarding the availability CONTACTS: NOTE: TO BE MADE PUBLICLY AVAILABLE WHEN THE FINAL SRM IS MADE AVAILABLE Frank M. Akstulewicz, NRR (301) 415-1136 Eileen M. McKenna, NRR (301) 415-2189
- The NRC issued 10 CFR 50.54(f) letters dated May 17, 1996, and August 9, 1996, to Northeast Utilities (NU) related to degraded and nonconforming conditions and failures to comply with the plant design bases at the Haddam Neck Plant.
The licensee responses to these 50.54(f) letters may serve to arswer, in whole or in part, the specific information identified in the p:oposed 50.54(f) letter attached. The staff will issue a unique letter to NU ta address the specific requirements of the attached, proposed 50.54(f) letter, the previously issued 50.54(f) letters, and the schedule for j responses. The proposed 50.54(f) letter does not apply to the Millstone units gl because NU is currently under a confirmatory order to perform an independent corrective action verification program that would satisfy the information I elements of the proposed letter. p. 0 {j & Lp)PTro "ow 5 MO %o90900 % YP 'k O h""^""
(. i 5 I The Commissioners < and adequacy of design bases information to identify how engineering design and configuration control processes are examined; design bases requirements are translated into operating, maintenance, and testing procedures; i performance of systems, structures, and components is verified to be within j the design bases; and problem identification and implementation of corrective actions are handled. l l BACKGROUND I In the mid-to late 1980's, NRC safety system functional inspections (SSFIs) and safety system outage modifi7 tion inspections (SS0 mis) at power reactor licensees raised concerns about design bases information not being properly maintained and plant modifications being made without the licensee having an understanding of the plant design bases. The NRC's findings heightened the nuclear industry's awareness of the need to improve the adequacy and availability of design documentation and many licensees voluntarily initiated extensive efforts to improve their design bases information. To assist the industry in performing these activities, the Nuclear Management and Resources Council (NUMARC), now the Nuclear Energy Institute (NEI), developed the guidance document NUMARC 90-12. " Design Basis Program Guidelines." The document outlined a standard framework for developing a program that collates design basis information and supporting design information, but does not identify or re-create the licensing basis of the plant. In a letter dated November 9, 1990, the staff concluded that the guidelines would provide worthwhile insights to those utilities undertaking design bases programs and appeared to provide sufficient flexibility for licensees to structure their programs to respond most efficiently to any unique needs and circumstances of a particular license. In emphasizing the importance of validation of the facility against current design information, the staff stated that the goal of any program should be to establish confidence that the existing facility conforms to the current design bases documents and that any identified deviations are reconciled. The staff also i emphasized that design documents that support technical specification values and that are necessary to support operations or to respond to events should be regenerated if missing. The staff requested that NUMARC consider making the design bases effort a NUMARC initiative. In SECY-91-364, " Design Basis Rsconstitution" dated November 12, 1991, the staff reported NUMARC's conclusion that an initiative was not necessary because most of their members were already conducting or evaluating the need to conduct such programs. Although NUMARC decided not to pursue a formal initiative, it agreed to forward the guidelines to its members for use on a voluntary basis. To provide more information to the industry on this topic and to provide an independent view of the design control issue, the staff conducted a survey of six utilities and one nuclear steam supply system vendor to determine the status of design control problems and the strengths and weaknesses of the sample utility programs. The results were published in February 1991 in
- -. -.. ~. -.. ~ _.. -.. -. -. -. _ -.- !-(' The Commissioners NUREG-1397, "An Assessment of Design Control Practices and Design Reconstitution Programs in the Nuclear Industry." The survey observations were: The need for a design documentation reconstitution program was directly proportional to the age of the plant. The general-intent of the program should be to provide a central location for design bases information, with emphasis on the design intent (the "why" of the design). The design bases documents should be a top-level directory which defines the current plant configuration. Reestablishment of design bases without reconstitution of the supporting design documents, as necessary, may not provide a sufficient level of information for future modifications or current plant operation, or to quickly respond to operating events. l Minor changes to the design should be tracked to support the conclusion that the changes in the aggregate do not affect the validity of existing calculations and the ability of a system to l perform its design functions. l Some common weaknesses of licensee programs identified during the survey included the following: Design reconstitution programs had not identified in advance the documents that are necessary to demonstrate that a structure, system, or component will function properly. The process for regenerating missing design documentation was not always proceduralized so that it could be handled in a systematic t manner. Validation of the content of specific output documentation was not l always thoroughl3 carried out. In late 1991, the Commission requested the staff to consider whether rulemaking, regulatory guidance, or a policy statement was needed to outline the NRC's expectations concerning accurate design bases documentation. In SECY-92-193, " Design Bases Reconstitution" dated May 26, 1992, the staff I concluded that additional regulations were not needed because existing regulatory requirements for design control were sufficient. However, the staff proposed issuance of a policy statement and of a generic letter for public comment requesting licensees to describe their programs. Additionally, SECY-92-193 documented the staff's intention to ccntinue performing design-l related inspections. Also, the staff expected that the enforcement policy guidance (to refrain from issuing civil penalties for violations up to Severity Level II if the issues were identified and corrected as a result of
i l* l l 1 l The Comissioners i i i systematic voluntary initiatives) would encourage licensees to identify past design, engineering, and installation issues. The Commission responded in a staff requirements memorandum (SRM) on SECY-92-193 which approved the staff's i l approach. ) In August 1992, the Comission issued the policy statement " Availability and Adequacy of Design Bases Information at Nuclear Power Plants" (57 FR 35455). This policy statement stressed the importance of maintaining current and j accessible design documentation to ensure that (1) plant physical and functional characteristics are maintained and consistent with design bases, j (2) systems, structures, and components can perform their intended functions, and (3) the plant is operated in a manner consistent with the design bases. In the policy statement, the Comission stated that all power reactor j' licensees should assos the accessibility and adequacy of their design bases. documentation and be able to show that there is sufficient documentation to t j conclude that the current facility configuration is consistent with the design i bases. The policy statement outlined further actions the staff would perform j to keep apprised of industry's activities. s Following review by the Committee to Review Generic Requirements (CRGR) and l the Commission, a draft generic letter was issued for public comment on March 24, 1993. The proposed generic letter requested licensees, on a 3 j voluntary basis, to submit information and schedules for any design bases i-programs completed, planned, or being conducted, or a rationale for not j implementing such a program. All but one of the comenters concluded that the generic letter was unnecessary and unwarranted. NUMARC responded that it believed the NRC's request for descriptions, schedules, and dates would have a 2 l negative impact on ongoing design efforts and that NRC's focus on schedules a would undermine the licensees' ability to manage the activities. i In SECY-93-292, " Generic Letter on the Availability and Adequacy of Design l Bases Information" dated October 21, 1993, the staff recommended the generic l letter not be issued. The staff stated that publication of the policy statement and the proposed generic letter conveyed to the industry the j Comission's concern, and that publication of the generic letter would not further licensees' awareness of the importance of the activities. The staff i j proposed to continue performing design-related inspections and to gather information and insights as to how well licensee's design-related programs i were being implemented. The Comission issued an SRM that agreed with the i staff's proposal. p 1 In response to the findings relating to the regulatory burden of team l inspections identified in the 1991 Regulatory Impact Survey, during -the past several years, the staff has reduced its effort on specific, resource-intensive, design-related team inspections, and followed the issue of accurate 1 and accessible design documentation at plants principally as an element of inspection and followup of operations-related activities. The issuance of the NUMARC guidelines and ongoing industry efforts to improve and maintain design 4 j bases information also contributed to this decision. i i i 1 .v~
= ) I k* j The Commissioners l I j DISCUSSION: 1 i Beginning in late 1995 during a number of inspections at different sites, the NRC found that design bases were not, in some cases, being appropriately maintained or adhered to by some licensees. Contrary to earlier indications and expectations, the staff now believes there are situations in which licensees have not critically examined their design control and configuration 'l i measures. For example, inspection teams identified a number of engineering calculations and analyses for key safety systems that were incorrect and did not confirm that safety system functional requirements would be met (resulting in inoperable safety systems on some occasions). Numerous instances were identified in which design basis information was not adequately translated into procedures, practices and drawings; the original design basis was inadequate and the original installation was incorrect; modifications were not installed in accordance with the design; and modifications were based on i incorrect design assumptions. Additionally, cases were identified in which quality assurance requirements and corrective action requirements had not been properly implemented to appropriately maintain design basis information. Details of the findings are out1. ired further in Attachment 2 to the proposed j letter. l By letter dated August 2, 1996, NEI informed the staff that an initiative had been approved by the Nuclear Strategic Issues Advisory Committee (consisting of chief nuclear officers) to provide addtional assurance and confidence to l NRC.that existing programs are adequate to ensure the following: (1) plants are operated in conformance with their licensing basis, (2) the licensing j basis is adequately maintained, (3) differences between the operating i practices and the licensing basis could not result in a significant public j health and safety concern, and (4) degraded or nonconforming conditions are captured on tracking systems and resolved in a timely. manner. In its letter, l NEI stated that each licensee would conduct an assessment of the program in place to reaffirm that plants are operated in conformance with their licensing basis. In a letter dated August 14, 1996, the NRC stated its concern that the proposed initiative may not be of sufficient scope and depth and that an in-depth vertical slice review of actual design basis documentation and a j comparison of "as-built" and "as-operated" safety systems would be more appropriata. The NRC confirmed its position that it is the responsibility of individual licensees to know their licensing basis, to have appropriate documentation that defines their design bases, and to have procedures in place for performing the necessary assessment of plant or procedure changes required j by NRC r~egulations. Design and configuration deficiencies being identified at some plants indicate the failure of licensees (1) to comply with the terms and conditions of 1 licenses and NRC regulatios and (2) to assure that Updated Final Safety i Analysis Reports properly describe the facilities. These findings raise questions as to whether licensee programs to maintain configuration control 1 are sufficient to demonstrate that plant physical and functical i characteristics are consistent with the design bases and whether operating ] plants are being maintained in accordance with their design basis. The staff ) i e
-The Commissioners believes that reliance on the industry's voluntary efforts to improve design bases information, consistent with NUMARC 90-12, the staff's comments on the industry guidelines, and the Commission policy statement, may have not been sufficient to maintain configuration control at some number of plants. These problems are of concern because of their pote.ntial impact on public health and safety should safety systems not respond to challenges from off-normal and accident conditions. Therefore, the staff proposes to send 10 CFR 50.54(f) letters (Attachment) to utility CE0s that require licensees to (1) submit a description of any programs already completed, planned, or being conducted to ensure correctness and accessibility of the design bases information or (2) submit a rationale for not implementing such a program and a description of the extent of design information already obtained from suppliers and vendors, and (3) submit a schedule for the completion date of any planned design reconstitution program. The program description should provide information regarding how engineering design and configuration control processes are examined; design bases requirements are translated into operating, maintenance, and testing procedures; performance of structures, systems, and components is verified to be within the design bases; and problems are identified and implementation of corrective actions are handled. The staff will use the information to prioritize and to better focus design-related inspections such as SSFis and SS0 mis to verify compliance with the terms and conditions of licenses and NRC regulations, and to assure that Updated Final Safety Analysis Reports properly describe the facilities. Such inspections sample the process and products of design bases information programs and, therefore, provide insights as to the effectiveness of licensee programs without reviewing the programs themselves. COORDINATION: In view of the need for timely information regarding this matter, comments or concurrence from the Advisory Committee on Reactor Safeguards (ACRS) were not sought. The CRGR was briefed on this action at an emergency meeting held on August 22, 1996, and its comments have been incorporated. The Office of the General Counsel has reviewed this paper and the enclosed sample letter and has no legal objection. RECOMMENDATION: That the Commission approve issuance of the letters under the signature of either the Chairman, the EDO, or the Director, Nuclear Reactor Regulation, s 1w Cme's'N. Tay1 xecutive Director for Operations
Attachment:
Proposed 50.54(f) Letter to Licensees
\\ j l Commissioners' comments or consent should be provided directly to the Office 1 of the Secretary by COB Monday, September 16, 1996. Commission Staff Office comments, if any, should be submitted to the Commissioners NLT September 9, 1996, with an information copy to the Office of the Secretary. If the paper is of such a nature that it requires additional 1 l review and comment, the Commissioners and the Secretariat should be apprised of l when corrments may be expected. j i DISTRIBUTION: Commissioners OGC OCAA -0IG OPA OCA ACRS REGIONS EDO SECY l ) 4 1
r PROPOSED 50.54(f) LETTER TO LICENSEES 1 / Attachment
mo orou 4 UNITED STATES {. g ,j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20666 4001 i \\...../ / [date] [ftse of Utility CE0] [ Title] [ Utility Name] [ Utility Address]
SUBJECT:
REQUEST FOR INFORMATION PURSUANT TO 10 CFR 50.54(f) REGARDING ADEQUACY AND AVAILABILITY OF DESIGN BASES INFORMATION
Dear.Mr.-[Name]:
The purpose of this letter is to require information that will provide the U.S. Nuclear Regulatory Commission (NRC) added confidence and assurance that .j' your plant (s) are operated and maintained within the design basis and any deviations are reconciled in a timely manner. l Backaround In the mid-to late 1980s, NRC safety system functio $al inspections (SSFIs) and safety system outage modification inspections (SS0 mis) identified concerns that design bases information was not being properly maintained and plant modifications were being made without the licenste having an understanding of the plant design bases. The NRC's findings heightened the nuclear industry's awareness of the need to improve the adequacy and availability of design documentation, and many licensees voluntarily initiated extensive efforts to improve the design bases information for their plants. To assist the industry in performing design basis' improvement programs, the Nuclear Management and Resources Council (NUMARC) developed a guidance document, NUMARC 90-12. " Design Basis Program Guidelines." These guidelines were intended to provide a stanpard framework for licensee programs to improve plant design bases information. The NRC staff reviewed the guidelines and provided comments to NUMARC in November 1990. In emphasizing the importance of validating the facility against-current design information, the staff stated that the goal of any program should be to establish confidence that the existing facility is in accordance with the current design documents and that 'NUMARC was consolidated into the Nuclear Energy Institute (NEI) on March 23, 1994. 'As discussed in NUMARC 90-12, these programs or efforts would emphasize collation of design basis information and the supporting design information, not the identification or re-creation of the licensing basis for a plant or the regeneration of missing analyses and calculations.
Mr. [Name] any deviations will be reconciled. The staff concluded that the NUMARC guidelines would provide worthwhile insights to utilities undertaking design g reconstitution programs and that the guidelines appeared to provide suff - it flexibility for licensees to structure their programs to respond most efficiently to any unique needs and circumstances of a particular licensee. _ The staff requested NUMARC to consider making design reconstitution a formal NUMARC initiative and commented that design documents that support technical specification values and that are necessary to support operations or respg'l to events should be renenerated if missing. NUMARC subsequently concluded that a formal initiati re was not necessary because most of its members were already conducting or valuating the need to conduct design reconstitution programs, and agreed to forward the guidelines, with the NRC's comments, to its members for use on a voluntary basis. To provide more information to the industry on this topic and to provide an independent view of the design control issue, the staff conducted a survey of six utilities and one nuclear steam supply system vendor to determine the status of design control problems and the strengths and weaknesses of the sample utility programs. The results were published in February 1991 in NUREG-1397, "An Assessment of Design Control Practices and Design Reconstitution Programs in the Nuclear Industry." The survey observations were as follows: The need for a design documentation reconstitution program was directly proportional to the age of the plant. The general intent of the program should be to provide a central location for design bases information, with emphasis on the design intent (the "why" of the design). The design bases documents should be a top-level directory that defines the current plant configuration. Reestablishment of design bases without reconstitution of the supporting design documents, as necessary, may not provide a sufficient level of information for future modifications or current plant operation, or to quickly respond to operating events. Minor changes to the design should be tracked to support the conclusion that the changes in aggregate do not affect the validity of existing calculations and the ability of a system to perform its design functions. Some common weaknesses of licensee programs identified during the survey included the following: Design reconstitution programs had not identified in advance the documents that are necessary to demonstrate that a structure, system, or component will function properly. l
a } Mr. [Name) : i The process for regenerating missing design documentation was not i j always proceduralized so that it could be handled in a systematic { manner. Validation of the content of specific output documentation was not l always thoroughly carried out. In late 1991, the NRC staff evaluated whether rulemaking, guidance, or a l policy statement was needed to address the issue of licensees retaining accurate design bases information. It concluded that the existing regulatory requirements for design control were adequate; however, it determined that the i publication of a policy statement addressing design bases information and publication of a generic letter requesting licensees to describe their design i reconstitution programs would be beneficial. Additionally, the staff stated its intention to continue to evaluate design control adequacy during its l performance-based inspections such as SSFIs and SSOMIs. The staff also expectedthattheenforcemgntpolicyguidancetoprovidegreateropportuni+4es for enforcement discretion would encourage voluntary identification of pas design, engineering, and installation issues by licensees. With the Commission's approval, the staff proceeded with this approach. In August 1992, the NRC issued the policy statement " Availability an'd Adequacy of Design Bases Information at Nuclear Power Plants" (57 FR 35455) (Attachment 1). This policy statement stressed the importance of maintaining current and l accessible design documentation to ensure that (1) plant physical and functional characteristics are maintained and consistent with design bases, j (2) systems, structures, and components can perform their intended functions, i and (3) the plant is operated in a manner consistent with the design bases. In the policy statement, the Commission recommended that all power reactor licensees assess the accessibility and adequacy of their design bases information and that they be able to show that there is sufficient i documentation to conclude that the current facility configuration is i consistent with the design bases. The policy statement outlined the l additional actions the NRC would take to keep apprised of the industry's design reconstitution activities previously discussed above. 3 l Following review by the Committee to Review Generic Requirements (CRGR) and j the Commission, a draft generic letter was issued for public comment on March 24, 1993. The proposed generic letter requested licensees, on a voluntary basis, to submit informaticn and schedules for any design bases programs completed, planned, or being conducted, or a rationale for not implementing i i such a program. All but one of the commenters concluded that the generic letter was unnecessary and unwarranted. NUMARC responded that it believed the j NRC's request for descriptions, schedules, and dates would have a negative i impact on ongoing design efforts and that NRC's focus on schedules would undermine the licensees' ability to manage the activities. l! i NRC would refrain from imposing civil penalties for violations up to Severity 3 l Level II if the violations were identified and corrected as a result of j systematic voluntary initiatives. 4.
I l Mr. (Name] ! In SECY-93-292, " Generic Letter on the Availability and Adequacy of Design Bases Information," dated October 21, 1993, the staff recommended that the generic letter not be issued. The staff stated that publication of the policy statement and the proposed generic letter conveyed to the industry the 4 Commission's concern and that publication of the generic letter would not i further licensees' awareness of the importance of the activities. The staff proposed to continue performing design-related inspections and to gather 1 information and insights as to how well the licensees' design-related programs were being implemented. The Commission issued a staff requirements memorandum that agreed with the staff's proposal. t In response to the findings relating to the regulatory burden of team inspections identified in the 1991 Regulatory Impact Survey, during the past j several years, the staff has reduced its effort on specific, resource-l intensive, design-related team inspections, and followed the issue of accurate l and accessible design documentation at plants principally as an element of inspection and followup of operations-related activities. The issuance of the l NUMARC guidelines and ongoing industry efforts to improve and maintain design bases information also contributed to this decision. s Current Problem i l Over the past several months, NRC's findings during inspections and revis - l have identified broad programmatic weaknesses that have resulted in design and configuration deficiencies at a number of plants which could impact the operability of required equipment, raise unreviewed safety questions, or 3 indicate discrepancies between the plant's updated final safety analysis report (UFSAR) and the as-built or as-modified plant or plant operating l procedures. These inspections and reviews have also highlighted numerous instances in which timely and complete implementation of corrective action for l known degraded and nonconforming conditions and for past violations of NRC i requirements has not been evident. Overall, the NRC staff has found that some licensees have failed (1) to appropriately maintain or adhere to plant l licensing and design bases information, (2)~ to comply with the terms and j conditions of licenses and NRC regulations, and (3) to assure that UFSARs properly reflect the facilities. Attachment 2 provides examples of some of the deficiencies recently identified by the staff. As a consequence of this new information, the NRC believes that the industry's voluntary efforts to improve and maintain design bases information for their plants, consistent i with NUMARC 90-12, the staff's comments on the industry guidelines, and the Commission policy statement, have not been effective in all cases. i i The magnitude and scope of the problems that the NRC staff has identified raise concerns about the presence of similar design, configuration, and operability problems and the effectiveness of quality assurance programs throughout the industry. Of particular concern is whether licensee pr3 grams i to maintain configuration control are sufficient to demonstrate that plant physical and functional characteristics are consistent with the design bases 1 and whether operating plants are being maintained in accordance with their j design basis. The extent of the licensee's failures to maintain control and to identify and correct the failures in a timely manner is of concern because l t 4
Mr. (Name) of the potential impact on public health and safety should safety systems not respond to challenges from off-normal and accident conditions. It is emphasized that the NRC position has been, and continues to be, that it is the responsibility of individual licensees to know their licensing basis, to have appropriate documentation that defines their design bases, and to have procedures for performing the necessary assessments of plant or procedure changes required by NRC regulations. Attachments 3 and 4 are a recent exchange of correspondence between J. Colvin, NEI, and Chairman S. Jackson, NRC, regarding these subjects. Action The NRC has concluded that it requires information that can be used to verify compliance with the terms and conditions of your license (s) and NRC regulations, and assure that the plant UFSAR(s) properly describe the facilities, and which may be used to decide whether to modify, suspend, or revoke the operating licente(s) for your facility or facilities, or whether other inspection activities or enforcement action should be taken. Therefore, you are required, pursuant to Section 182(a) of the Atomic Energy Act of 1954, as amended, and 10 CFR 50.54(f), to submit a response to this letter within 120 days of its reieipt. Your response must be written and signed under oath or affirmation. Please submit your response to the Director, Office of Nuclear Reactor Regulation, with a copy to the appropriate regional administrator and to the NRC Document Control Desk. The following information is required for each licensed unit: (1) A description of any design review or reconstitution programs, including identification of the systems, structures, and components, and plant-level design attributes (e.g., seismic, high-energy line break, moderate-energy line break), that have already been completed, are planned, or are being conducted to ensure the correctness and accessibility of the design bases information for your plant and to ensure that it is maintained current. If the program is planned or being conducted but has not been completed, provide an implementation schedule for systems, structures, and components, and plant-level design attribute reviews and the expected completion date. (2) A rationale for not implementing such a program, if no design review or reconstitution program has been implemented or planned. The responses provided pursuant to paragraphs (1) and (2) above should address how current or planned plant processes or programs address the following areas of particular interest, as expressed in NUMARC 90-12, the staff's comments on the industry guidelines, and the Commission policy statement:
Mr. [Name) (a) Description of engineering design and configuration control l processes, including those that implement 10 CFR 50.59, 10 CFR 50.71(e), and Appendix B to 10 CFR Part 50. ) (b) Selection and prioritization of systems, structures, and components for review (item (1) only). (c) Rationale for concluding that design bases requirements are translated into operating, maintenance, and testing procedures. (d) Rationale for concluding that system, structure, and component' configuration and performance are consistent with the' design bases. (e) Processes for problem identification and implementation of corrective actions, including actions to determine the extent of problems, action to prevent recurrence, and reporting to NRC. (f) The overall effectiveness of your current processes and programs in concluding that the configuration of your plant (s) is consistent with the design bases. This request is covered by the Office of Management and Budget (0MB) clearance i number 3150-0011, which expires July 31, 1997. The reporting burden for this collection of information is estimated to average 400 hours per response,- including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to the Information and Records Management Branch (T-6F33), U.S. Nuclear Regulatory Commission, Washington, D.C. 20555-0001, and to the Desk Officer, Office of Information and Regulatory Affairs, NE08-10202 (3150-0011), Office of Management and Budget, Washington, D.C. 20503. The NRC may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB control number. In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter and your response will be placed in the NRC Public Document Room (PDR), the Gelman Building, 2120 L Street, N.W., Washington, DC, and in the local public document room (s) for your facility or facilities. l
9 Mr. [Name] j l l i If you have any questions about this matter, please contact the staff members i listed below, or the appropriate Office of Nuclear Reactor Regulation (NRR) l project manager. Sincerely, l [ Signature Block] Attachments: ) 1. Policy Statement on Availability and Adequacy of Design Bases Information at Nuclear Power Plants i 2. Background Information on Recently Identified Problems 3. Letter from J. Colvin (NEI) to Chairman S. Jackson (NRC) dated 8/2/96 4. Letter from Chairman S. Jackson (NRC) to J. Colvin (NEI) dated 8/14/96 Contacts: Frank M. Akstulewicz, NRR (301) 415-1136 Internet: fma9nrc. gov Eileen M. McKenna, NRR (310) 415-2189 Internet: emm9nrc. gov Docket No(s). 50-xxx and 50-xxx cc: See next page [ applicable plant service list]
35453 r d-i "sta Rules and Regulations Vol. 57. No.154 htonday. August to.1W2 Th.s section of the FEDERAL REGISTER Program Culdelines." NUMARC 90-12. functional characteristics are contains regulatory documents having While developing these guidelines, maintained and are consistent with the general apphcability and legal effect, most NUMARC discussed them at several design bases as required by NRC of which are keyed to and codified it) public meetings held with the NRC.The regulation. (2) systems, structures, and the Code of Federal Regulations, which is staff has concluded the NUMARC components can perform their intended I hed under 50 titles pursuant to 44 guidelines provide a useful standard functions, and (3) the plant is operated framework for implementing design in a manner consistent with the design The Code of Federal Regulations is sofd reconstitution programs.The staff also bases.The Commission believes the by the Supenntendent of Documents. Pnces of new books are listed in the agrees no single approach would enable regulatory framework already exists to first FEDERAL. REGISTER issue of each utilities to best accomplish the address the need for accessible design week. reconstitution task.The NUMARC bases and control of design information. guidance appeared to provide sufficient The availability of current design and flexibility for individual utilities to licensing bases will also expedite the NUCLEAR REGULATORY pructure their programs to respond most license renewal process. COMMISSION eIficiently to their unique needs and The Commission believes, as a result circumstances. of NRC inspections and licensees'self-10 CFR Part 50 The staff sent comments on the assessments, that all power reactor guidelines to NUMARC on November 9. licensees should assess the accessibility Avattability and Adequacy of Design 1990. Commission paper SECY-90-385 and adequacy of their design bases Bases Information at Nuclear Power informed the Commissioners in advance documentation.The results of this self. Plantst Policy Statement about the staff response to NUMARC. assessment should form the basis for a AGENCv: Nuclear Regulatory The staff requested NUMARC licensee's decision whether a design Commission. consider making the design bases effort reconstitution program is necessary and ACTION: Policy statement. a NUMARC initiative. NUMARC the attributes to be included in the concluded they would not pursue a program. The Commission recognizes
SUMMARY
- The Nuclear Regulatory formal initiative. but would forward the the need for a design reconstitution Commission is issuing this policy guidelines to their members to use on a program to be tailored to meet the statement on availability and adequacy voluntary basis. Their reason for not unique needs of a particular utility.The of design mformation at nuclear power pursuing an initiative was that most of structure and content of the design plants. This policy statement describes their members were already conducting document reconstitution program will be the Commission;s expectations and or evaluating the need to conduct design influenced by various factors. such as future actions with regard to the bases reconstitution programs-the utility's organizational structure. the availability of design information and The Commission's evaluation of the availability or unavailability of design emphasizes the Commission s view that status of reconstitution programs clearly documentation. and the intended users facilities should not be modified without indicates the licensees' substantial of the documentation.The Commission a clear understanding of the applicable investment in these programs should expects that after completing a engineering design bases.
yield positive safety benefits for a reconstitution program, or as a basis for EFFECTIVE D ATE: August 10.1992. majority of sites.The NRC commends concluding that such a program is those licensees that are acting to ensure unnecessary. the licensee will have FOR FURTHER INFORM ATION CONTACT: Eugene V. imbro, Office of Nuclear technically adequate and accessible current design documents and adequate Reactor Regulation. U.S. Nuclear design bases documentation is technical bases to demonstrate that the Regulatory Commission. Washington. maintained-plant physical and functional Flowever, the Commission is characteristics are consistent with the DC 20555. telephone (301) 504-2907. concerned some situations exist where design basis, the systems, structures. SUPPL.EMENT ARY INFORM ATION: NRC licensees have not critically examined and components can perform their Inspection findings have demonstrated their design control and configuration intended functions and the plant is bein? that some licensees have not adequately management processes to identify operated in a manner consistent with maintained their design bases requisite measures to ensure the plant is the design basis. information as required by NRC regulations. Both the problems identified operating within the de:agn bases. NUMARC has developed guidance for envelope. Therefore, the Commission is the conduct of design bases during the NRC inspections and those articulating its expectations with regard reconstitution programs. The guidance identified by licensees have prompted to design informetton and elaborating on outlines a framework to organite and niost power reactor licensees to initiate, its planned activities to confirm the collate nuclear power plant design bases over the past several years, design miegrity of the as configured plant with information. This information provides bases reconstitution programs. To resput to the plant design bases. the rationale for the design bases implement a reconstitution program. consistent with the definition of design licensees seek to identify missing design Policy Statement bases contained in to CFR 50.2. documentation and to selectively Position NUMARC 90-12. " Design Basis Program regenerate missing documentation as The Commission has concluded that Cuidelines." was issued in October 1990 required. In 1989. Nuclear Utilities Management maintaining current and accessible for voluntary use by NUMARC member and Resources Council. Inc.. (NUMARC) design documentation is important to organizations as a reference point from began developing their " Design Basis ensure that (1) the plant physical and which licensees would review their s410999 nnol(00XUb AUG 92-12On 29)
35456 Feda?al Register / Vol. 57. No.154 / Monday. August 10. 1992 / Rules and Regulations exis'ing or planned efforts to collate ensure their validity for the life of the DEPARTMENT OF THE TREASURY [ supporting design information.The facility, including any renewal period. Commission believes NUMARC's In order to ensure the Commission is Office of Thrift Supervision i approach provides a useful framework appraised of industry's activities the 12 CFH Part 584 g and worthwhile insights to those utilities NRC will take the following actions. undertaking design basis programs. (1)The staff willissue a genericletter 192-1951 The Commission believes a licensee requesting alllicensees to describe the blN 1550-AA38 should be able to show that it has programs that are in place to ensure sufficient documentation. including design information is correct, accessible. Registration Examination and calculations or pre operational. startup and maintained current. Those lleensees Reports; Statements, Applications, or surveillance test data to conclude the that are not implementing a design Reports and Notices To Be Filed current facility configuration is reconstitution program will be requested consistent with its design bases.The to provide their rationale for not doing AGENCY: Office of Thrift Supervision. Commission further believes the design so. lf a reconstitution program is under Treasury. bases must be understood and way, the schedule for implementation ACTION: Final rule. documented to support operability and completion will be requested. determinations and 10 CFR 50.59
SUMMARY
- The Office of Thrift
, (2)The staff will prioritize NRC Supervision (OTS) is hereby amending evaluations that may need to be made quickly in responding to plant events. inspections of licensee's management of its regulations pertaining to holding The design bases related information design and configuration using SSFl* company reporting requirements. In should be retrievable within a type techniques based upon responses updating existing forms to reflect reasonable period of time, however, it is to the generic letter and other plant changes necessitated by the Financial not necessary for all design basis specific information known to the NRC. Institutions Reform. Recovery, and documentation to be organized in one Additional staff guidance will be Enforcement Act of 1989, the OTS has place.The information used solely to developed. where needed. for the design combined several forms to streamline support the development of a bases aspects of these inspections. the reporting process and este the regulatory burden on savings and loan modification package would not need t (3) The NRC systematic assessment of holding companies. In particular, the be able to be retrieved as expeditiously licensee performance (sal.P) process reporting requirenents set forth in as information needed to support an will be modified to explicitly address Forms H-(b)3. H-{bl4. H-(b)5 and H-operability determination. assessment of licensee programs t (b)10 Registration Statements are now in the event the design bases control design bases information that contained in one body of instructions for , formation is found technically reflect NRC inspection activity in this all Registrants. the H-(b]10. In addition, in inadequate or not accessible. ficenscas area and assure consistent evaluations. the H-(b)11 Annual Report and the H-should consider whether remedial action (b)12 Current Report have been merged is warranted. A methodology should be (41 The staff will continue t into one set of instructions requiring an developed and implemented to ensure encourage self identification of desig annual filing with quarterly updates licensee resources are focused on design bases issues through application of the informing the OTS of any changes.The information regeneration in a timeframe provisions of the Commission's . Il-(f) Dividend Notification has been commensurate with the safety enforcement policy.The staff will, rescinded since the requirements sigmficance of the missing or erroneous however, pursue enforcement actions for contained in the Capital Distributions information. engineering deficiencies whose root regulation are sufficient for the OTS's cause lies in the inadequacy or monitoring and supervision purposes. The Commission also emphasizes it is unavailability of design bases EFFECTtyt DATE: September 0.1992. very important that modifications to a int rmation and which are identified facility be made after a thorough review FOR FURT! DER INFORMATION CONTACT: has been conducted and an during NRC inspections. Michael P. Scott Program Manager, understanding of the applicable (202) 906-5748. Supervision policy, underlying design bases has been Paperwork Reduct. ion Act Statement Office of Thrift Supervision.1700 C gained in order to ensure appropriate This final policy statement does not Street. NW.. Washington DC 20552. design margins are preserved. contain a new or amended information SUPPLEMENTARY INFORMATION: collection requirement subject to the
1. Background
Future Actions Paperwork Reduction Act of1980(44 U.S.C. 3501 et seq.). Existing The OTS is today issuing a final rule The Comm.ission will continue to requirements were approved by the amending its holding company reporting inspect routinely the adequacy of design Office of Management and Budget requirements.This amendment affects control program effectiveness.The approval number 3150-0011. the registration, annual, and current Commission concludes that ensuring the reporting requirements. design bases and configuration of a Dated at Rockvihe. Marylend, this 4th day facility are well understood and of August.1992. controlled in plant documents will also As previously structured, holding ensure that those parts of the current For the Nuclear Regulatory Commission. companies were required to choose from licensing bases of most safety four separate registration statements. significance are understood and Sa muel l. Chilk. These separate statements were controlled. Other aspects of the current Secretary of the Commission. originally deemed necessary to mm a M %M d WM licensing bases, such as emergency lFR Doc. 92-t8895 Filed 84-92; 8.45 an) companies (f Wi.e. companies that becam preparedness and security plans, should oma cm nm savings and loan holding companies as also be appropriately examined to S-110999 0002(00X0LA1)G 02-12 00J2) < -v m e,. < < r. e m. en me u
^l BACKGROUND INFORMATION ON RECENTLY IDENTIFIED PROBLEMS Over the past several months, design and engineering information has been 4 obtained that indicates that design bases at certain plants have not been j appropriately maintained or adhered to. Specific examples follow: Millstone Units 1. 2. and 3 i An NRC inspection team recently found examples in which the Updated Final 4 Safety Analysis Report (UFSfR) and design bases information did not agree with the as-built plant, operational procedures, and maintenance practices which were resolved by correcting the documentation. The team found other more significant inconsistencies that required analyses, procedure changes, and design changes to resolve. For example, the Millstone Unit 3 operating l procedures required isolation for the turbine-driven auxiliary feedwater pump during certain plant conditions, in conflict with technical specification requirements for operability. The team found that certain protective relays ] at Millstone Unit 3 were not set in accordance with the design bases information. This required re-analyses and resetting of certain relays. Based on the team's findings, the licensee initiated design changes to correct j nonconforming conditions between the UFSAR and the as-built plant, including changes to the design of the Millstone Unit 2 reactor protection system to meet the design bases with respect to physical separation of redundant channels and changes to the design of the Millstone Unit 2 (post-loss-of-coolant accident (LOCA)) hydrogen monitors to meet the design bases for single failure vulnerabilities. Haddam Neck The team found examples in which the UFSAR and design bases information did not agree with the as-built plant, operational procedures, and maintenance practices which were resolved by correcting the documentation. The team identified a number of deficiencies in engineering calculations and analyses that were relied upon to ensure the adequacy of the design of key safety systems. The team found examples of inconsistencies between the as-built } plant, vendor-supplied information, and the assumptions used in engineering calculations and analyses. Deficiencies were identified in the calculations and analyses supporting the station batteries, emergency diesel generators, containment cooling system, and other key safety systems. In some cases, the i inspection findings were resolved by revising the calculations and analyses. t In other cases, procedure and design changes were required to resolve the issues. For example, the team identified that the design bases calculations supporting the size of the station batteries were inconsistent with the design I bases stated in the FSAR. Field measurements and design modifications were l required to resolve this issue. Additional examples are documented in the special team inspection report for Haddam Neck, 50-213/96-201. Other issues were identified by the NRC and the licensee following the issuance of this inspection report that lead the licensee to enter a refueling outage earlier than originally scheduled. These issues include discrepancies between the as-built plant and the design bases for the service water system pressure, containment sump screens, feedwater isolation valves, and containment penetrations. i
l 4 Maine Yankee On January 10, 1996, the NRC issued a Confirmatory Order Suspending Authority for and 1.imiting Power Operation and Containment Pressure and a Demand for Information to the Maine Yankee Atomic Power Company. The order was based, in part, on the NRC's determination that Maine Yankee did not apply a computer code, proposed to demonstrate compliance with the emergency core cooling system (ECCS) requirements of 10 CFR 50.46, in a manner conforming to the requirements of 10 CFR Part 50, Appendix K, nor in conformance to the conditions specified in the staff's safety evaluation dated January 30, 1989. Specifically, the licensee did not demonstrate that the RELAP5YA code will reliably calculate the peak cladding temperature for all break sizes in the small-break LOCA spectrum for Maine Yankee, nor has the licensee submitted the justification for the code options selected and other justifications and sensitivity studies to satisfy conditions in the staff's safety evaluation. In addition, the licensee assumed an initial containment pressure of 2.0 psig for calculating paak design-basis accident pressure, even though the plant's technical specifications allow a maximum operating pressure in containment of 3.0 psig. Assuming an initial containment pressure of 3.0 psig results in a - calculated peak accident pressure in excess of the containment design pressure described in the UFSAR. Refuelina Practices Survey In response to recent problems encountered at Millstone Unit I regarding conformance of the facility with the UFSAR, during the spring of 1996, the NRC conducted a survey of licensee refueling practices. During the course of this survey, the NRC_ determined that nine sites (15 units) needed to modify their licensing basis or plant practices to ensure that their reload practices were in compliance with their licensing basis. Deficiencies in the management of design bases assumptions were also noted in-the survey. Many plants were found to have aspects of their design and licensing bases that were only loosely proceduralized or not proceduralized at all. Typical of this kind of discrepancy was the identification of a lack of procedures for controlling the assumptions regarding hold-up time before beginning fuel transfer. The NRC found a number of instances in which other design bases assumptions were not captured in procedures. In addition, licensees at 12 other sites (23 units) upgraded procedures to directly implement the design bases assumptions. In other cases, the licensee performed engineering analyses, documented pursuant to 10 CFR 50.59, as necessary, to ensure that the planned activities would not exceed design bases assumptions. QEI t' \\V(llAR (h[R6Y INiilIJ I! Joe F. Colvin August 2,1996 The Honorable Shirley A. Jackson Chairman U.S. Nuclear Regulatory Commission Washington, DC 20555 0001
Dear Chairman Jackson:
On July 23,1996, the Nuclear Strategic Issues Advisory Committee (NSIAC) held a special meeting to discuss industry actions for ensuring the licensing basis of nuclear plants is being maintained consistent with the regulations. The chief nuclear officers of the nuclear utilities approvc:d an initiativa to provide additional assurance and con 6dence that existing programs are adequate to ensure that: Licensees are operating their plants in conformance with their licensing basis: Licensees are adequately maintaining their licensing basis: There are no differences between operating practices and the licensing basis that could result in a significant public health and safety concern; and Degraded or non conforming conditions are captured on tracking systems and resolved in a timely manner. Under the initiative, each licensee will conduct an assessment of the programs in place to reaffirm that plants are operated in conformance with their licensing basis. The program assessment is accomplished by sampling (1) FSAR information, (2) programs in place for processing changes to procedures and the plant that may impact the FSAR, and (3) changes that may not be governed by licensee programs. Many licensees have already commenced or recently completed similar program assessments. Differences identified through the sampling process will be evaluated to assess the overall effectiveness and adequacy of programs. Programmatic enhancements will be made if needed. The overall significance of any ditTerences will be characterized to determine if additional sampling is warranted. Differences that represent degraded or nonconforming conditions will be captured on a tracking system and resolved in a timely manner. Each licensee will notify the NRC of any differences that are subject to reporting requirements per the regulations.
I The Honorable Shirley A. Jackson August 2,1996 Page 2 1 i. The results of the individual plant assessments will be provided to NEl for comptlation in an industry summary report. The summary report wul be provided j l to the NBC for information. The industry has developed a draft guideline to assist utilities in performing the l programmatic assessment. The guideline will be finalized subsequent to resolution of the issues discussed below. Enclosure 1 provides a copy of NEI 96 05 (Draft) l Revision D. " Guidelines for Assessing Programs for Maintaining the Licensing ,4 Basis," for your information. There are a number of related issues that require a mutual agreement between the industry and the NRC before the industrv can proceed with the initiative in a consistent manner These include: j . The legal standing of the l'pdated Final Safety Analysis Report and the NRC's Safety Evaluation Reports: The scope of what constitutes the current licensing basis: and The adequacy of SSAC 125 for performing 10 CFR 50.59 safety evaluations. 1 1 The industry is committed to completing the initiative within six months of the resolution of these issues. Initial progress in resolving these issues was accomplished during the NRC public meeting also held on July 23.1996. We i appreciate very much the participation of your senior staffin this meeting and the epportunity to discuss these issues. Expedited closure on these fundamentalissues is needed to minimize confusion within the NRC regions and the plants and focus j our resources on addressing the programmatic issues. We look forward to a continuing dialogue with the Commission and NRC staff to achieve timely resolution of this matter. Sincerely, a 4 (4 AL (J F.Coh-in s Snclosure Comnussioner Kenneth C. Rogers. NRC c: Commissioner Greta J. Dicus. NRC \\t. Taylor. NRC .\\1r. Jame3
I a NEI 96-05 (DRAFT) Revision D 1 1 1 NUCLEAR ENERGY INSTITUTE 1 1 GUIDELINES FOR ASSESSING PROGRAMS FOR' 4 MAINTAINING THE LICENSING BASIS i 1 i JULY 25,1996
1.0 INTRODUCTION
Licensees have implemented various programs / processes over the period of their licenses for ensuring that the licensing basis is known, is maintained current and is accurately described in the FSAR and associated referenced documents. The NRC, through a review described in SECY 94 066, determined that licensees were adequately maintaining the licensing basis of their facilities. As a result of events that have occurred over the last several months, the NRC has increased attention on licensee compliance with the plant's licensing basis. Differences can occur due to problems in those processes / programs intended to effect changes in the license basis, missing programmatic controls to translate changed ope rational activities into the licensing basis, or a lack of awareness oflicensing basis features. Licensees employ various programmatic mechanisms for identifying, evaluating anCor processing changes in plant activities that could affect the licensing basis or the are intended to make changes to the licensing basis. These include: Final Safety Analysis Report (FSAR) updates per 10 CFR 50.71(e) Safety Evaluations per 10 CFR 50.59 Changes to Quality Assurance. Security and Emergency Plans per 10 CFR 50.54 License amendments per 10 CFR 50.90 ASME Code relief requests per 10 CFR 50.55a Procedure changes (not subject to 50.59) Design changes (not subject to 50.59) Regulatory commitment changes Degraded or non-conforming conditions Configuration management changes (e.g., operator workarounds, extended operation of equipment in manual mode rather than automatic operation modes, and Technical Specification positions / interpretations) 1
1 1 { ' 2.0 PURPOSE AND SCOPE i 2.1 Purpose This do:ument provides guidance for performing a self assessment of the adequacy of programmatic controls for maintaining the licensing basis in order to identify j missing or incorrectly applied programmatic elements that can lead to licensing i j basis differences. 4 2.2 Scope i The assessment approach consists of a data gathering phase and an evaluation phase. The data gatbring phase employs a three tiered sampling technique. The first tier involves in-process sampling for the programmatic elements intended to effect a change in the licensing basis. Since programmatic elements may be missing 1 or incorrectly applied, the next two sampling tiers involve a search for differences by sampling for potential operational changes that could be made without L procedure changes, and sampling backwards by comparing selected FSAR statements with operational practices. The purpose of the data gathering phase is to identify a set of potential differences between the operational practices and the licensing basis. The evaluation phase determines if potential differences are valid. Valid 4 differences are categorized in order to draw conclusions about the adequacy of particular programmatic controls for maintaining the licensing basis. The l significance of the findings are used to develop recommendations for programinatic l enhancements. 1 j It is recognized that many licensees have performed safety system functional inspections (SSFIs) and other reviews that have assessed the adequacy of their i programs to maintain the licensing basis of their plants and to ensure the accuracy ofinformation in the FSAR. These completed activities can be credited, as appropriate, in meeting portions of the assessment described below. The assessment methodology described below represents only one way of performing the assessment of the adequacy and effectiveness of programs for maintaining the licensing basis. Although the methodology contains a reasonable amount of detail, it is not intended to be prescriptive. Other approaches that I provide an equivalent scope of review can also meet the intent of this asscssment. i 3 i ) .) es T
i 0 50.54 (one each from QA. EP and Security) 0 Outstandmg corrective action for a matarial condition greater than one year old j 0 Operating procedure change not evaluated under 50.59 ) 0 FSAR change request j 0 50.90/50.55a change and associated SER (where NRC approval has been received) 0 Regulatory commitment addition or change O Design change not evaluated under 50.59 NOTE: The changes selected should have been completed in suf6cient tune to have been reflected (if required) in the most recent licensing basis update of the FSAR. QA program. etc. Review the change to determine if the change should have appeared in the licensing basis and. if so. if the licensing basis accurately reflects the change. For changes that are not accurately reDected in the licensing basis, determine the programmatic step (or missing programmatic step) that would have ensured its accurate incorporation into the licensing basis. \\ Document the results of the programmatic sampling. 3.1.3 Sampling for potential changes that may occur separate from programmatic or procedure changes Compile the following: 0 Workaround list 0 Operations standing orders 0 Technical Speci5 cations positions / interpretations (if any) > Sample of documents that may show potentially routine "NA'ing" of procedure steps (e.g., last completed startup procedure. recently completed system operating instructions. shift supervisor loc entries for deviations > 4
'I J 4
3.0 ASSESSMENT
METHODOLOGY i 3.1 Data-Ga ' ing Phase The data gathering phase of the assessment employs three sampling techmques. 3 Each sampling technique is discussed separately. 3.1.1 FSAR Sampling
- l Extract the relevant FSAR sections for the system (s) being evaluated
' Highlight those FSAR statements that meet the following criteria: e 0 Descriptive phrases regarding frequencies for tests, calibrations, etc. 4 0 ConSguration descriptions 4 0 Descriptions of system operation in different modes (e.g.. normal, abnormal. accident / emergency)
- - Operating limits l
0 Descriptive functional performance statements NOTE: The intent is to identify a range of FSAR statements associated with operational practices that could be changed and, in the presence of programmatic weaknesses. are not adequately reflected in the FSAR. Compare the highlighted FSAR s.atements with current operational practices using individuals cognizant of the operation of the system and associated engineering problems. Document the following: 0 Is the FSAR statement accurat e with respect to operational practices (procedures, operating philosophy, standing orders, workarounds, etc.)? ) If not, identify the differences. i 0 Is the FSAR statement clearly understood or in need of clarification? 3.1.2 Prograrnmatic Sampling Select three unrelated examples of each of the following types of changes:*
- - 50.59 ( at least one procedure change evaluation) 3
~ 4 O List of equipment being operated in manual ? Old* temporary alterations 2 0 Old* non-conformances E > Old* tag outs I l "Old" refers to current items that should be reDected (if required) in the last ) I FSAR update per 10 CFR 50.71(e) 1 Select a sample from each of the above categories based on the number of items compiled. j Review the item selected to determine if the item represents a change to the ] licensing basis and, if so, if the licensing basis accurately reDects the change. For changes that are not accurately reGected in the licensing basis, determine the programmatic step (or missing programmatic step) that would i ' have ensured its accurate incorporation into the licensing basis. Document the results of the sampling. i a 3.2 Evaluation Phase At this point in the assessment, the changes to operating practices that should have beeit reDected in the licensing basis have been identined. Those not i accurately reDected in the licensing basis are differences that must be resolved j and categorized. I The evaluation phase cannot be precisely structured. Howes the folL broad steps should be undertaken. Categorize differences in accordance with the following criteria: O Procram/ process which should have ensured licensing basis accuracy 0 Signiscance Safety signi5 cant Regulatory significant (i.e. noncomphance or missed commitment) i Low sient5cance (e.g.. the oriemal information was not required to be included in the FSAR. or the information could not have been 1 5
r 4 relied upon by the NRC in reaching a safety conclusion) [ NOTE: Section V of NDIARC 9012, " Design Basis Program Guidelines," provides guidance for assessing the safety significance of differences and for determining if operability and/or reporting issues exist.) ~0 50.59 wac correctly / incorrectly applied .a O Licensing basis information has always been inaccurate (i.e., there was no change in operating practice) Identify areas of programmatic weakness or missing programmatic controls. 3 If uncertain, pursue additional assessment investigation for the programmatic area in question. Characterize overall significance of the Sndings. Based on this characterization, determine the need to broaden the assessment scope to obtain the necessary confidence that the programs are adequate and are being effectively implemented. If applicable. generate necessary quality deSciency documents and identify any reportable situations. ) Prepare recommendations to address programmatic weaknesses. Document the results and brief appropriate management. i 4.0 STIREPORT J 4.1 Purpose of Report i e NEI will compile the overall industry results to assess the composite adequacy and effectiveness of programs designed to maintain the licensing basis of tba plants. The overall industry results will be reported to the NRC by NEI. 4.2 Report Format The report format follows the steps contained in Section 3.0 of this report. i Part 1 - FSAR Samplinst Identify the FSAR systems reviewed under Section 3.1.1. Indicate the number of FSAR differences identined. 6
1 1 Part 2 - Programmatic Samoline Indicate the total number ofitems reviewed. Indicate the number ofitems where the change was not accurately reDected in the licensing basis, Part 3 - Samoling for notential changes that mav occur separate from programmatic or orocedure chanres Indicate the total number ofitems reviewed. Indicate the number ofitems where the change was not accurately reDected ) in the licensing basis, if required. i Part 4 - Evaluation Phase Indicate the number of differences that were characterized as being safety signiEcant. Indicate the number of differences that were characterized as being regulatory signi6 cant. Indicate the number of differences where 50.59 was incorrectly applied. Indicate the number of differences where the licensing basis information has always been inaccurate. Provide a brief summary of the programmatic deSciencies identined, if any. Indicate whether the assessment scope is being broadened based on the identtSed differences. Describe any departures from the methodology of this guideline. 5.0 DEFINITIONS 5.1 Regulatory Commitment NEI" Guideline for Managing NRC Commitments," endorsed by NRC in SECY.95 300, defines a regulatory commitment as follows: "Resrulatory Commitment means an explicit statement to take a specinc action agreed to or volunteered by a licensee that has been submitted ir writing on the docket to the Commission." 5.2 Licensing Basis 10 CFR Part 54 dennes the current "licensmg bam as follows: 7
1 " Current licensing basis (CI.B) is the set of NRC requirements applicable to a specific plant and a licensee's written commitments for ensuring compliance with and operation within applicable NTC requirements and the plant specific design basis (including all modifications and additions ] to such commitments over the life of the license) that are docketed and in effect. The CLB includes the NRC requirements contained in 10 CFR parts 2,19. 20, 21. 30, 40, 50, 51, 54, 55, 70, 72, 73, and 100 and j appendices thereto; orders: license conditions; exemptions; and technical specifications. It also includes the plant specific' design basis j information defined in 10 CFR 50.2 as documented in the most recent final safety analysis report (FSAR) as required by 10 CFR 50.71 and the ) i licensee's commitments remaining in effect that were made in docketed licensing correspondence such as licensee responses to NRC bulletins. l generic letters, and enforcement actions, as well as licensee commitments documented in NRC safety evaluations or licensee event reports." l NOTE: Responses to NRC bulletins. generic letters and licensee event i i reports contain some commitments that are outside the scope of the CLB j in that they are not necessary to ensura compliance with applicable NRC ) requirements (e.g., rules. regulations, licenses and ordersi or to maintain the plant-specific design basis. w i l l 9
UNITED STATES NUCLEAR REGULATORY COMMISSION 8 ) N WASHINGTON, O C. 20355-0001 j j o August 14, 1996 \\.w....f CHAIRMAN Mr. Joe F. Colvin President and Chief Executive Officer Nuclear Energy Institute Suite 400 i 1776 I Street, N.W. Washington, D.C. 20006-3708
Dear Mr. Colvin:
I am responding to your letter of August 2, 1996, concerning industry actions for assessing programs in place to reaffirm that nuclear power plants are operated in conformance with their licensing basis. Your letter also identified three issues that, in your view, require mutual agreement between the industry and the Nuclear Regulatory Commission (NRC) before the industry 1 would proceed with the initiative: (1) the legal standing of the Updated Final Safety Analysis Report (FSAR) and the NRC's Safety Evaluation Reports; (2) the scope of what constitutes the current licensing basis; and (3) the adequacy of NSAC-125, " Guidelines for 10 CFR 50.59 Safety Evaluations," for performing 10 CFR 50.59 evaluations. .We believe that resolution of the issues you identified is not.a prerequisite to reviewing, on a retrospective basis, whether existing programs are sufficient to ensure-that licensees know their licensing bases, whether licensing bases have been properly maintained, and whether licensing bases are accurately described in each facility's updated FSAR or other documents. The significant issues recently identified by licensee reviews and NRC staff inspections relate to failures to address degraded and nonconforming conditions properly, failures to perform reviews required by 10 CFR 50.59 before making changes to facilities, and failures to update facility Final Safety Analysis Reports in accordance with 10 CFR 50.71(e). In our view, industry initiatives can proceed notwithstanding that ongoing NRC activities under the 10 CFR 50.59 Action Plan will consider, in a broad sense, issues such as those you raise. Existing regulations and guidance are sufficient to conduct a retrospective review for conformance to existing regulatory requirements. These include: (1) NRC reg >tlations 10 CFR 50.2, 50.34, 50.54, 50.59, 50.71(e), 50.72, 50.73 and Appendix B; (2) NRC's policy statement - Availabi'lity and Adequacy of 10, 1992; Design Bases Information at Nuclear Power Plants, 57 FR 35455 August (3) " Design Bases Program Guidelines," NUMARC 90-12 and NRC letter dated November 9, 1990; and (4) Generic letter 91-18, "Information To Licensees Regarding Two NRC Inspection Manual Sections On Resolution Of Degraded And Nonconforming Conditions And Operability." Attechment 4
' i 1 The staff ~is cor.cerned, however, that the proposed initiative may not be of i sufficient scope and depth to identify tha types of design and operability j problems recently identified at several operating plants. Specifically, it is not sufficient to perform a process / procedural based review. An in-depth vertical slice review of actual design basis documentation and comparison of "as built" and "as operated" safety systems is more appropriate. For example, reviews similar to safety system functional inspections 1 (Inspection Procedure 93801 " Safety System Functional Inspections"), may be used to evaluate a licensee's program effectiveness to maintain the licensing and design bases. These reviews should include: (1) an in-depth review of selected systems' design and design basis since issuance of the facility operating license; (2) risk-and safety-based criteria for selection of 1 systems for review; and, (3) a method to ensure that licensee. problem identification and corrective action on the selected systems are representative and consistent with other systems. The in-depth review should 1 examine: (1) engineering design and configuration control; (2) verification of as-built and as-modified conditions; (3) translation of the design bases requirements into operating procedures, maintenance, and testing; (4) verification of system performance through review of test records and j observations of selected testing: (5) proposed and implemented corrective i actions for licensee-identified design deficiencies; and, (6) modifications made to the systems since initial licensing. j In shurt, the NRC position has been, and is, that it is the responsibility of individual licensees to know their licensing basis, to have appropriate documentation that defines their design basis, and to have procedures for performing the necessary assessments of plant or procedure changes required by NRC regulations. Until such time that any regulation changes are made as a result of NRC action plan activities, we will continue inspection and oversight activities related to the design basis to ensure compliance with existing regulations. Sincerely, N Shirley Ann Jackson l l 1}}