REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.: NR-0355-D-105-E DATE: October.1, 1996 PAGE 1 OF 3 DEVICE TYPE: -Smoke Detector MODEL:
SIH-24, AIB-10, AI_ Series l
MANUFACTl'RER / DISTRIBUTOR :
Hochiki America Corporation 5415 Industrial Drive Huntington Beach, CA 92649 l
SEALED SOURCE MODEL DESIGNATION:
NRD Model A-001 Amersham.Model AMM1001 t
ISOTOPE:
MAXIMUM ACTIVITY:
l.
' Americium-241 1.0 microcurie (37.0 kBq)
LEAK TEST FREOUENCY:
Not required PRINCIPAL USE:
(P) Ion Generator, Smoke Detectors-CUSTOM DEVICE:
YES X
NO l
9610210008 961011 PDR RC SSD PDR 1
i
1 REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.- NR-0355-D-105-E DATE: October 1, 1996 PAGE 2 OF 3 DEVICE TYPE:
Smoke Detector DESCRIPTION:
The SIH-24 and AIB-10 smoke detectors are industrial type detectors connected to and operated from a central fire control unit.
These detectors are designed such that the radioactive material is not readily accessible to installers or users.
The SIH-24 and AIB-10 use the same ion chamber.
The only physical difference between the SIH-24 and the AIB-10 is in the overall size of the detectors, and that the SIH-24 has a small LED.
The SIH-24 is approximately 4" (10 cm) in diameter and 1.5" (3. 8 cm) in height.
The AIB-10 is approximately 3" (7.5 cm) in diameter and 1.75" (4.4 cm) in height.
The AI_ Series smoke detectors are also industrial type detectors that are connected to and operated from a central fire control unit.
The series includes the models AIE and AIC detectors.
The basic ion chamber design and construction for the two models within the series is essentially similar.
Cosmetic differences, including different outer cases, account for slight dimensional differences.
The following is a comparison of the ion chamber construction:
Description AIE AIC Isotope / Activity Am-214, 1.0 pCi Am-241, 0.98 pCi Source Holder Diameter 0.44" (11.2 mm) 0.44" (11.2 mm)
Inner Electrode Length 0.71" (18 mm) 0.35" (9 mm)
Intermediate Electrode 1.65" (4 2 mm) 1.46" (37 mm)
Diameter Outer Electrode 1.97" (50 mm) 1.73" (44 mm)
Diameter Hochiki distributes these detectors under different trade names, and includes the different product codes on the point of sale labeling.
J
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.- NR-0355-D-105-E DATE: October 1, 1996 PAGE 3 OF 3 DEVICE TYPE:
Smoke Detector
REFERENCES:
The following supporting documents for the smoke detector models SIH-24, AIB-10 and AI Series are hereby incorporated by reference and are made a part of this registry document.
- Hochiki America Corporation's applications dated August 22, 1995, and June 7, 1996, with enclosures thereto.
- Hochiki America Corporation's facsimiles dated December 7, 1994, June 18, 1996, July 1, 1996, July 2, 1996, August 14, 1996, August 19, 1996, September 19, 1996, and September 27, j
1996, with enclosures thereto.
- Hochiki America Corporation's letters dated November 24, 1987, November 25, 1989, June 25, 1990, September 5,
- 1990, June 2, 1994, November 30, 1994, and June 7, 1996, with enclosures thereto.
- NRD Incorporated's telefax dated March 26, 1991, with enclosures thereto.
ISSUING AGENCY:
U.S.
Nuclear Regulatory Commission M,
Date:
October 1, 1996 Reviewer:
n4-w Douglas A.
Broaddus Date:
October 1, 1996 Concurrence:,
?)0 Steven L.
Baggett