ML20128P391

From kanterella
Jump to navigation Jump to search
Forwards Rev 2 to Calculation YAEC-25Q-301, Flaw Evaluation for UT Indication Using Appenda Program.
Date released: 05/21/2020 Download: ML20128P391


Rev 0 to YAEC-25Q-301, Flaw Evaluation Indications for UT Appenda Program.
ML20128P393
Person / Time
Site: Vermont Yankee Entergy icon.png
Issue date: 10/07/1996
From: Markovits C
STRUCTURAL INTEGRITY ASSOCIATES, INC.
To:
References
Download: ML20128P393 (26)
Forwards Rev 2 to Calculation YAEC-25Q-301, Flaw Evaluation for UT Indication Using Appenda Program.
ML20128P386
Person / Time
Site: Vermont Yankee Entergy icon.png
Issue date: 10/09/1996
From: Duffy J
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML20128P386 (1)