Mr. J.P. O'Hanlon October 10,' 1996 Senior Vice President - Nuclear

, Virginia Electric and Power Company 5000 Dominion Blvd.

Glen Allen, Virginia 23060

SUBJECT:

NORTH ANNA UNIT 2 - INSERVICE INSPECTION PROGRAM RELIEF REQUESTS NOS. NDE-23 THROUGH NDE-30.

(TAC (2L. M95201 AND M95202)

Dear Mr. 0'Hanion:

The NRC staff, with technical assistance from our contractor, the Idaho National Engineering Laboratory (INEL), has reviewed and evaluated the information you provided in letters dated August,2, 1995, and September 1, 1955, related to the Second 10-Year Interval Inservice Inspection Program Requests for Relief Nos. NDE-23 through NDE-30.for North Anna Power Station, Unit 2.

Based on the'information submitted, the staff adopts the contractor's.

conclusions and recommendations presented in the enclosed Technical Letter Report. The staff concluded that Code. requirements contained in Requests for Relief Nos. NDE-23 through NDE-30 are impractical because of interferences and/or limited accessibility by other components.

Replacement of the component or design modification would be necessary to perform the Code-required examinations Lthat would result 'in a burden on.the licensee. The licensee's proposed alternatives will provide adequate assurance of structural integrity.

Therefore, the licensee's Requests for Relief Nos. NDE-23 through NDE-30 are granted pursuant to 10 CFR 50.55a(g)(6)(i). This relief granted and the alternatives imposed are authorized by law, will not endanger life, property, or common defense and' security, and are otherwise in the public interest, giving due consideration to the burden upon the licensee that could result if the requirements were imposed.

This completes our efforts on this issue and we are, therefore, closing out Tac. Nos. M952016and M95202.

Sincerely, (Original Signed By)

Mark Reinhart, Acting Director Project Directorate 11-1 Dft Db h 05000038 Division of Reactor Projects - I/II Q

PDR Office of Nuclear Reactor Regulation Docket Nos. 50-338 and 50-339 f

Enclosures:

I 1.

Safety Evaluation 2.

Technical Letter Report cc w/encis:

See next page 1700GG Distribution Docket File S. Varga 0GC NRC FR.E CENTER CWY PUBLIC J. Zwolinski ACRS PDII-1 RF

  • Previously Concurred FILENAME - G:\\NOANNA\\M95201.LTR OFFICE LA:PDII PMa@IU1 OGC* NLO ECGB*

AD:PDII-1 NAME DunnikgTon BBuNley MYoung GBagchi MReinhartN DATE

  1. /9/96 10 /4 /96 9/25/96 09/06/96 10 / $/96 hNo kehNo Yes/No Yes/No hsho COPY m

Mr. J. P. O'Hanlon North Anna Power Station Virginia Electric & Power Company Units 1 and 2 cc:

Mr. William C. Porter, Jr.

Regional Administrator, Region Il County Administrator U.S. Nuclear Regulatory Commission Louisa County 101 Marietta Street, N.W.,

P.O. Box 160 Suite 2900 Louisa, Virginia 23093 Atlanta, Georgia 30323 Michael W. Maupin, Esquire Mr. W. R. Matthews, Manager Hunton and Williams North Anna Power Station Riverfront Plaza, East Tower P. O. Box 402 951 E. Byrd Street Mineral, Virginia 23117 Richmond, Virginia 23219 Mr. Al Belisle Dr. W. T. Lough U.S. Nuclear Regulatory Commission Virginia State Corporation 101 Marietta Street N. W. Suite 2900 Commission Atlanta, Georgia 30323-0199 Division of Energy Regulation P. O. Box 1197 Mr. David Christian, Manager Richmond, Virginia 23209 Surry Power Station Virginia Electric and Power Company Old Dominion Electric Cooperative 5570 Hog Island Road 4201 Dominion Blvd.

Surry, Virginia 23883 Glen Allen, Virginia 23060 Mr. M. L. Bowling, Manager Nuclear Licensing & Operations Support Virginia Electric and Power Company Innsbrook Technical Center 5000 Dominion Blvd.

Glen Allen, Virginia 23060 Office of the Attorney General Commonwealth of Virginia 900 East Main Street Richmond, Virginia 23219 Senior Resident Inspector North Anna Power Station U.S. Nuclear Regulatory Commission 1024 Haley Drive Mineral, Virginia 23117 Robert B. Strobe, M.D., M.P.H.

State Health Commissioner Office of the Commissioner Virginia Department of Health P.O. Box 2448 Richmond, Virginia 23218

.